Investigation into the Elastic Properties of ex vivo Porcine Corneas Subjected to Inflation Test after Cross-Linking Treatment

S. Matteoli, A. Virga, I. Paladini, R. Mencucci, A. Corvi
{"title":"Investigation into the Elastic Properties of ex vivo Porcine Corneas Subjected to Inflation Test after Cross-Linking Treatment","authors":"S. Matteoli, A. Virga, I. Paladini, R. Mencucci, A. Corvi","doi":"10.5301/jabfm.5000262","DOIUrl":null,"url":null,"abstract":"Background The aim of this work was to evaluate the effect of cross-linking (CXL) on ex vivo porcine corneal elastic properties, using an inflation procedure. Methods Twelve corneas were subjected to standard CXL (370 nm, 3 mW/cm2, 30 minutes), while 12 were used as controls. Corneal thickness was measured by Visante optical coherence tomography, before and immediately after treatment, and before inflation test. Both intraocular pressure and radial apical cornea displacement were measured during inflation. Stress-strain curves were obtained by applying the linear shell theory. The elastic modulus was evaluated by calculating the slope of the stress-strain curves. Results Results showed a statistically significant increase in elastic modulus (p<0.0001), with a mean of 3,868 ± 502 kPa for cross-linked corneas and 2,727 ± 238 kPa for untreated corneas, when subjected to high pressure (40-60 kPa). CXL significantly increased porcine cornea stiffness by about 42%. Findings did not show any significant difference within the physiological range of pressure (2-4 kPa). Conclusions The inflation test has been proven to be a valuable tool for the investigation of corneal biomechanics, maintaining both integrity and geometry of corneal tissue.","PeriodicalId":51074,"journal":{"name":"Journal of Applied Biomaterials & Biomechanics","volume":"14 1","pages":"163 - 170"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5301/jabfm.5000262","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomaterials & Biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5301/jabfm.5000262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

Background The aim of this work was to evaluate the effect of cross-linking (CXL) on ex vivo porcine corneal elastic properties, using an inflation procedure. Methods Twelve corneas were subjected to standard CXL (370 nm, 3 mW/cm2, 30 minutes), while 12 were used as controls. Corneal thickness was measured by Visante optical coherence tomography, before and immediately after treatment, and before inflation test. Both intraocular pressure and radial apical cornea displacement were measured during inflation. Stress-strain curves were obtained by applying the linear shell theory. The elastic modulus was evaluated by calculating the slope of the stress-strain curves. Results Results showed a statistically significant increase in elastic modulus (p<0.0001), with a mean of 3,868 ± 502 kPa for cross-linked corneas and 2,727 ± 238 kPa for untreated corneas, when subjected to high pressure (40-60 kPa). CXL significantly increased porcine cornea stiffness by about 42%. Findings did not show any significant difference within the physiological range of pressure (2-4 kPa). Conclusions The inflation test has been proven to be a valuable tool for the investigation of corneal biomechanics, maintaining both integrity and geometry of corneal tissue.
交联处理后猪离体角膜充气试验弹性性能的研究
本研究的目的是评估交联(CXL)对离体猪角膜弹性性能的影响。方法将12只角膜进行标准CXL (370 nm, 3 mW/cm2, 30 min)处理,12只角膜作为对照。在治疗前、治疗后和充气试验前,用Visante光学相干断层扫描测量角膜厚度。充气过程中测量眼压和径向角膜顶位移。应用线性壳理论得到了应力-应变曲线。通过计算应力-应变曲线的斜率来计算弹性模量。结果结果显示,交联角膜的弹性模量在高压(40-60 kPa)下平均增加3,868±502 kPa,未处理角膜的弹性模量平均增加2,727±238 kPa,具有统计学意义(p<0.0001)。CXL可显著提高猪角膜硬度约42%。结果显示,在生理压力范围(2 ~ 4 kPa)内无显著差异。结论膨胀试验是研究角膜生物力学的有效工具,可保持角膜组织的完整性和几何形状。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Biomaterials & Biomechanics
Journal of Applied Biomaterials & Biomechanics 生物-材料科学:生物材料
自引率
0.00%
发文量
0
审稿时长
12 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信