{"title":"RESEARCH OF ELECTRIC POWER QUALITY OF TRACTION SUBSTATIONS OF A HIGH MOUNTAIN MINER","authors":"R. Klyuev, O. Fomenko, I. Bosikov, O. Gavrina","doi":"10.46689/2218-5194-2021-4-1-399-415","DOIUrl":null,"url":null,"abstract":"The paper presents a methodology for researching the levels of higher harmonic in networks with a voltage of 6 kV and developed measures to eliminate harmonics of the non-canonical series. According to the results of the research, it was found that the sources of high-er harmonic ones are the ATP-500 traction substations, connected to the 6 kV network in groups and alone. In the 6 kV network, the 3rd, 5th, 7th and 11th harmonics of the canonical series, as well as the 3rd, 4th, 6th and 8th harmonics of the non-canonical series, are distin-guished, the levels of which significantly exceed the permissible levels according to GOST. The presence of non-canonical harmonics is caused by the asymmetry of the bridge circuit (current asymmetry relative to the abscissa axis). An instruction has been developed for the pre-start check of the bridge circuit gates to eliminate asymmetry. The prevalence of 5 and 7 higher harmonics in the 6 kV network was established and it was recommended to take into account the possibility of resonance phenomena in the pulse-phase control circuits of electric drives connected to the 6 kV network of the mine and open pit. The implementation of the recommen-dations set forth in the work increases the reliability of the bridge circuits of traction substa-tions and eliminates the possibility of the appearance of non-canonical harmonics, which im-proves the voltage quality in accordance with the requirements of GOST.","PeriodicalId":41869,"journal":{"name":"Proceedings of the Tula States University-Sciences of Earth","volume":"1 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Tula States University-Sciences of Earth","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46689/2218-5194-2021-4-1-399-415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
The paper presents a methodology for researching the levels of higher harmonic in networks with a voltage of 6 kV and developed measures to eliminate harmonics of the non-canonical series. According to the results of the research, it was found that the sources of high-er harmonic ones are the ATP-500 traction substations, connected to the 6 kV network in groups and alone. In the 6 kV network, the 3rd, 5th, 7th and 11th harmonics of the canonical series, as well as the 3rd, 4th, 6th and 8th harmonics of the non-canonical series, are distin-guished, the levels of which significantly exceed the permissible levels according to GOST. The presence of non-canonical harmonics is caused by the asymmetry of the bridge circuit (current asymmetry relative to the abscissa axis). An instruction has been developed for the pre-start check of the bridge circuit gates to eliminate asymmetry. The prevalence of 5 and 7 higher harmonics in the 6 kV network was established and it was recommended to take into account the possibility of resonance phenomena in the pulse-phase control circuits of electric drives connected to the 6 kV network of the mine and open pit. The implementation of the recommen-dations set forth in the work increases the reliability of the bridge circuits of traction substa-tions and eliminates the possibility of the appearance of non-canonical harmonics, which im-proves the voltage quality in accordance with the requirements of GOST.