Determination of Vitamin D3 Loaded Selfnanoemulsifying Drug Delivery Systems (SNEDDS) Based Hydrogel

IF 0.6 Q4 PHARMACOLOGY & PHARMACY
Adeltrudis Adelsa DANIMAYOSTU, E. Lukitaningsih, R. Martien, Retno Danarti
{"title":"Determination of Vitamin D3 Loaded Selfnanoemulsifying Drug Delivery Systems (SNEDDS) Based Hydrogel","authors":"Adeltrudis Adelsa DANIMAYOSTU, E. Lukitaningsih, R. Martien, Retno Danarti","doi":"10.29228/jrp.410","DOIUrl":null,"url":null,"abstract":": High Performance Liquid Chromatography (HPLC) was used to determine vitamin D3 content from the topical dosage form. Self-nanoemulsifying drug delivery systems (SNEDDS) based hydrogel was aimed to optimize the delivery of vitamin D3 through the skin due to its high lipophilicity. Quantifying vitamin D3 was performed using the internal standard, vitamin D2, on LiChrocart C18 125-4 reverse phase column. Several characteristics of validation were referred including specificity, linearity, range, accuracy, precision, limits of detection, and quantification. The mobile phase was optimized as a mixture of acetonitrile-methanol-water for injection 94:3:3 v/v, and the flow rate was optimized at 0.8 mL/min at 25°C. Vitamin D3 detection and quantification were observed at a wavelength of 266 nm using an ultra-violet (UV) detector. The analysis method performed no excipient interference, including separating vitamin D3 from its matrix. Extraction of vitamin D3 from its matrix was observed using the dialysis membrane, with agitation (vortex) and no agitation (immersion). The drug content determination was found to be 108.22 % ± 14.77% for the immersion method and 72.04% ± 33.37% for the vortex method. Further, the high variability of the results indicated the dialysis membrane was not a suitable method for determining lipophilic drug content from the colloidal polymer matrix. The other techniques with negligible variation, such as reverse dialysis or subsequent solvent addition, are preferred.","PeriodicalId":17096,"journal":{"name":"Journal of Research in Pharmacy","volume":"1 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research in Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29228/jrp.410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

: High Performance Liquid Chromatography (HPLC) was used to determine vitamin D3 content from the topical dosage form. Self-nanoemulsifying drug delivery systems (SNEDDS) based hydrogel was aimed to optimize the delivery of vitamin D3 through the skin due to its high lipophilicity. Quantifying vitamin D3 was performed using the internal standard, vitamin D2, on LiChrocart C18 125-4 reverse phase column. Several characteristics of validation were referred including specificity, linearity, range, accuracy, precision, limits of detection, and quantification. The mobile phase was optimized as a mixture of acetonitrile-methanol-water for injection 94:3:3 v/v, and the flow rate was optimized at 0.8 mL/min at 25°C. Vitamin D3 detection and quantification were observed at a wavelength of 266 nm using an ultra-violet (UV) detector. The analysis method performed no excipient interference, including separating vitamin D3 from its matrix. Extraction of vitamin D3 from its matrix was observed using the dialysis membrane, with agitation (vortex) and no agitation (immersion). The drug content determination was found to be 108.22 % ± 14.77% for the immersion method and 72.04% ± 33.37% for the vortex method. Further, the high variability of the results indicated the dialysis membrane was not a suitable method for determining lipophilic drug content from the colloidal polymer matrix. The other techniques with negligible variation, such as reverse dialysis or subsequent solvent addition, are preferred.
基于水凝胶的维生素D3自纳米乳化给药系统(SNEDDS)的测定
采用高效液相色谱法测定外用剂型中维生素D3的含量。基于水凝胶的自纳米乳化药物递送系统(SNEDDS)旨在优化维生素D3通过皮肤的递送,因为它具有高亲脂性。采用内标维生素D2,在LiChrocart C18 125-4反相柱上定量。包括特异性、线性度、范围、准确度、精密度、检出限和定量在内的几个验证特性被提及。流动相优化为乙腈-甲醇-注射用水94:3:3 v/v,流速优化为0.8 mL/min,温度25℃。采用紫外(UV)检测器在266 nm波长下对维生素D3进行检测和定量。该分析方法无辅料干扰,包括将维生素D3从基质中分离出来。用透析膜从基质中提取维生素D3,有搅拌(涡流)和无搅拌(浸泡)。浸渍法和涡流法分别为108.22%±14.77%和72.04%±33.37%。此外,结果的高度可变性表明透析膜不是测定胶体聚合物基质中亲脂性药物含量的合适方法。其他变化可忽略不计的技术,如反透析或随后的溶剂添加,是优选的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Research in Pharmacy
Journal of Research in Pharmacy PHARMACOLOGY & PHARMACY-
CiteScore
1.00
自引率
12.50%
发文量
80
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信