{"title":"Study and Construction of New Polymeric Electrodes in PVC Matrix Membrane for Amiloride Hydrochloride Drug Determination","authors":"S. A. Abrahem, S. Ibrahim, A. Kader","doi":"10.33422/2nd.icarbme.2019.12.945","DOIUrl":null,"url":null,"abstract":"Based on Amiloride hydrochloride-methyl orange, two electrodes of Amiloride hydrochloride were constructed in PVC matrix as ion pair complex. They were plasticized using Nitrobenzene (NB), and Di-butyl phosphate (DBP). Amiloride hydrochloride (AMH) electrodes (e1and e2) presented slopes (54.210 and 52.810 mV/decade) and linear ranges (10-5-10-2, and 2*10-5-10-2 M), respectively. (e1), which is the best electrode, was based on DBP plasticizer. It gave a detection limit of 4x10-6M, slope of 54.210 mV/decade, correlation coefficient 0.9998, lifetime 36 days. The proposed electrode displayed reproducibility and good stability and was used for determining Amiloride hydrochloride in pharmaceutical samples. The interference measurements using (Na+, Cu+2, K+, Fe+3, and Mn+2) were studied for selectivity coefficient determination using the separated method, as well as the mixed method","PeriodicalId":15222,"journal":{"name":"Journal of Cardiovascular Disease Research","volume":"11 1","pages":"150-155"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Disease Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33422/2nd.icarbme.2019.12.945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Based on Amiloride hydrochloride-methyl orange, two electrodes of Amiloride hydrochloride were constructed in PVC matrix as ion pair complex. They were plasticized using Nitrobenzene (NB), and Di-butyl phosphate (DBP). Amiloride hydrochloride (AMH) electrodes (e1and e2) presented slopes (54.210 and 52.810 mV/decade) and linear ranges (10-5-10-2, and 2*10-5-10-2 M), respectively. (e1), which is the best electrode, was based on DBP plasticizer. It gave a detection limit of 4x10-6M, slope of 54.210 mV/decade, correlation coefficient 0.9998, lifetime 36 days. The proposed electrode displayed reproducibility and good stability and was used for determining Amiloride hydrochloride in pharmaceutical samples. The interference measurements using (Na+, Cu+2, K+, Fe+3, and Mn+2) were studied for selectivity coefficient determination using the separated method, as well as the mixed method