{"title":"Basic Finite Element Analysis of Para-periodontal Ligament in All-ceramic Zirconia Fixed Partial Denture.","authors":"Syuntaro Nomoto, S. Matsunaga, Toru Sato, Mamoru Yotsuya, S. Abe","doi":"10.2209/tdcpublication.56.215","DOIUrl":null,"url":null,"abstract":"The purpose of the present study was to investigate the validity of incorporating a para-periodontal ligament in the test mold used in a basic fracture test of a zirconia all-ceramic fixed partial denture (FPD). A simplified three-dimensional finite element analysis model was designed based on the three-unit FPD fracture test. Two types of model, one with and one without a para-periodontal ligament between the abutment and base mold, were fabricated. Microfocus CT of the missing first molar area in a dry human mandible was performed. A three-dimensional model was then fabricated based on the data obtained. A load of 600 N was applied to the center of the pontic and stress distribution observed. The model with the para-periodontal ligament showed stress dispersion to the dental root with rotation of the abutment mold. Stress distribution in the finite element analysis model with a para-periodontal ligament showed greater similarity with that in the mandibular model than with that in the other two models without a para-periodontal ligament.","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":"56 4 1","pages":"215-22"},"PeriodicalIF":0.5000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2209/tdcpublication.56.215","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.56.215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3
Abstract
The purpose of the present study was to investigate the validity of incorporating a para-periodontal ligament in the test mold used in a basic fracture test of a zirconia all-ceramic fixed partial denture (FPD). A simplified three-dimensional finite element analysis model was designed based on the three-unit FPD fracture test. Two types of model, one with and one without a para-periodontal ligament between the abutment and base mold, were fabricated. Microfocus CT of the missing first molar area in a dry human mandible was performed. A three-dimensional model was then fabricated based on the data obtained. A load of 600 N was applied to the center of the pontic and stress distribution observed. The model with the para-periodontal ligament showed stress dispersion to the dental root with rotation of the abutment mold. Stress distribution in the finite element analysis model with a para-periodontal ligament showed greater similarity with that in the mandibular model than with that in the other two models without a para-periodontal ligament.