{"title":"Simulation of Magnetic Resonance Sounding With a Delayed Adiabatic Pulse","authors":"Benquan Yang;Yujing Yang","doi":"10.1109/LMAG.2022.3196597","DOIUrl":null,"url":null,"abstract":"Magnetic resonance sounding (MRS) is used to identify groundwater by exciting and measuring the nuclear magnetic resonance of hydrogen nuclei in subsurface aquifers. However, the MRS response is particularly weak and has a low signal-to-noise ratio (SNR); therefore, signal enhancement methods, such as adiabatic pulses, are essential for MRS applications with strong interference. The key challenges of utilizing this novel method are to increase the MRS signal response and sensitivity for field measurements. In this letter, we present an improved transmitting mode of a commonly used adiabatic half-passage pulse by combining this pulse with an earlier fixed frequency off-resonant pulse of short duration, thereby increasing the theoretical MRS sensitivity. Simulation results demonstrate that the approach could be used to further improve the signal responses, i.e., in terms of the SNR and potential resolution, for MRS exploration of high-noise environments.","PeriodicalId":13040,"journal":{"name":"IEEE Magnetics Letters","volume":"13 ","pages":"1-5"},"PeriodicalIF":1.1000,"publicationDate":"2022-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Magnetics Letters","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/9850383/","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Magnetic resonance sounding (MRS) is used to identify groundwater by exciting and measuring the nuclear magnetic resonance of hydrogen nuclei in subsurface aquifers. However, the MRS response is particularly weak and has a low signal-to-noise ratio (SNR); therefore, signal enhancement methods, such as adiabatic pulses, are essential for MRS applications with strong interference. The key challenges of utilizing this novel method are to increase the MRS signal response and sensitivity for field measurements. In this letter, we present an improved transmitting mode of a commonly used adiabatic half-passage pulse by combining this pulse with an earlier fixed frequency off-resonant pulse of short duration, thereby increasing the theoretical MRS sensitivity. Simulation results demonstrate that the approach could be used to further improve the signal responses, i.e., in terms of the SNR and potential resolution, for MRS exploration of high-noise environments.
期刊介绍:
IEEE Magnetics Letters is a peer-reviewed, archival journal covering the physics and engineering of magnetism, magnetic materials, applied magnetics, design and application of magnetic devices, bio-magnetics, magneto-electronics, and spin electronics. IEEE Magnetics Letters publishes short, scholarly articles of substantial current interest.
IEEE Magnetics Letters is a hybrid Open Access (OA) journal. For a fee, authors have the option making their articles freely available to all, including non-subscribers. OA articles are identified as Open Access.