Vincenzo Sesta;Klaus Pasquinelli;Renato Federico;Franco Zappa;Federica Villa
{"title":"Range-Finding SPAD Array With Smart Laser-Spot Tracking and TDC Sharing for Background Suppression","authors":"Vincenzo Sesta;Klaus Pasquinelli;Renato Federico;Franco Zappa;Federica Villa","doi":"10.1109/OJSSCS.2021.3116920","DOIUrl":null,"url":null,"abstract":"We present the design and experimental characterization of a CMOS sensor based on Single-Photon Avalanche Diodes for direct Time-Of-Flight single-point distance ranging, under high background illumination for short-range applications. The sensing area has a rectangular shape (\n<inline-formula> <tex-math>$40\\,\\,\\mathbf {\\mathrm {\\times }}\\,\\,10$ </tex-math></inline-formula>\n SPADs) to deal with the backscattered light spot displacement across the detector, dependent on target distance, due to the non-confocal optical setup. Since only few SPADs are illuminated by the laser spot, we implemented a smart laser-spot tracking within the active area, so to define the specific Region-Of-Interest (ROI) with only SPADs hit by signal photons and a smart sharing of the timing electronics, so to significantly improve Signal-to-Noise Ratio (SNR) of TOF measurements and to reduce overall chip area and power consumption. The timing electronics consists of 80 Time-to-Digital Converter (TDC) shared among the 400 SPADs with a self-reconfigurable routing, which dynamically connects the SPADs within the ROI to the available TDCs. The latter have 78 ps resolution and 20 ns Full-Scale Range (FSR), i.e., up to 2 m maximum distance range. An on-chip histogram builder block accumulates TDC conversions so to provide the final TOF histogram. We achieve a precision better than 2.3 mm at 1 m distance and 80% target reflectivity, with 3 klux halogen lamp background illumination and 2 kHz measurement rate. The sensor rejects 10 klux of background light, still with a precision better than 20 mm at 2 m.","PeriodicalId":100633,"journal":{"name":"IEEE Open Journal of the Solid-State Circuits Society","volume":"2 ","pages":"26-37"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/8782712/9733783/09555913.pdf","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of the Solid-State Circuits Society","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9555913/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
We present the design and experimental characterization of a CMOS sensor based on Single-Photon Avalanche Diodes for direct Time-Of-Flight single-point distance ranging, under high background illumination for short-range applications. The sensing area has a rectangular shape (
$40\,\,\mathbf {\mathrm {\times }}\,\,10$
SPADs) to deal with the backscattered light spot displacement across the detector, dependent on target distance, due to the non-confocal optical setup. Since only few SPADs are illuminated by the laser spot, we implemented a smart laser-spot tracking within the active area, so to define the specific Region-Of-Interest (ROI) with only SPADs hit by signal photons and a smart sharing of the timing electronics, so to significantly improve Signal-to-Noise Ratio (SNR) of TOF measurements and to reduce overall chip area and power consumption. The timing electronics consists of 80 Time-to-Digital Converter (TDC) shared among the 400 SPADs with a self-reconfigurable routing, which dynamically connects the SPADs within the ROI to the available TDCs. The latter have 78 ps resolution and 20 ns Full-Scale Range (FSR), i.e., up to 2 m maximum distance range. An on-chip histogram builder block accumulates TDC conversions so to provide the final TOF histogram. We achieve a precision better than 2.3 mm at 1 m distance and 80% target reflectivity, with 3 klux halogen lamp background illumination and 2 kHz measurement rate. The sensor rejects 10 klux of background light, still with a precision better than 20 mm at 2 m.