Improving the Performance of Direct-Conversion SDRs for Radiated Precompliance Measurements

IF 0.9 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
C. Spindelberger;H. Arthaber
{"title":"Improving the Performance of Direct-Conversion SDRs for Radiated Precompliance Measurements","authors":"C. Spindelberger;H. Arthaber","doi":"10.1109/LEMCPA.2022.3227409","DOIUrl":null,"url":null,"abstract":"In this letter, a highly linear front end to improve the performance of software-defined radio (SDRs) for radiated precompliance measurements is presented. In CISPR band C/D, the test receiver needs to fulfill stringent requirements for using the quasi-peak detector. Usually, an expensive preselection filter bank is necessary to make fully compliant measurements of broadband transients. Direct-conversion-based SDRs show a limited out-of-the-box performance for precompliance measurements caused by, e.g., harmonic mixing and saturation effects. With the use of a triple-balanced mixer, a highly linear upconversion stage is built, eliminating the need for a filter bank. The dynamic range (DR) requirements for the SDR are strongly reduced by a narrowband intermediate frequency filter, making CISPR 16-1-1 compliant measurements possible. The sensitivity of the front end is comparable to professional receivers on the market, although no low-noise amplifier is implemented. The performance is verified by continuous wave (CW) and transient signals according to CISPR norms. The broadband measurement results are compared with traditional characterizations of the DR using the compression level and the noise figure. It shows that assumptions on the RF-link budget for a compliant design can be made with CW measurements. Based on our results, the requirements for the SDR front end are derived.","PeriodicalId":100625,"journal":{"name":"IEEE Letters on Electromagnetic Compatibility Practice and Applications","volume":"5 1","pages":"22-26"},"PeriodicalIF":0.9000,"publicationDate":"2022-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/8566057/10079119/09973334.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Letters on Electromagnetic Compatibility Practice and Applications","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/9973334/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 2

Abstract

In this letter, a highly linear front end to improve the performance of software-defined radio (SDRs) for radiated precompliance measurements is presented. In CISPR band C/D, the test receiver needs to fulfill stringent requirements for using the quasi-peak detector. Usually, an expensive preselection filter bank is necessary to make fully compliant measurements of broadband transients. Direct-conversion-based SDRs show a limited out-of-the-box performance for precompliance measurements caused by, e.g., harmonic mixing and saturation effects. With the use of a triple-balanced mixer, a highly linear upconversion stage is built, eliminating the need for a filter bank. The dynamic range (DR) requirements for the SDR are strongly reduced by a narrowband intermediate frequency filter, making CISPR 16-1-1 compliant measurements possible. The sensitivity of the front end is comparable to professional receivers on the market, although no low-noise amplifier is implemented. The performance is verified by continuous wave (CW) and transient signals according to CISPR norms. The broadband measurement results are compared with traditional characterizations of the DR using the compression level and the noise figure. It shows that assumptions on the RF-link budget for a compliant design can be made with CW measurements. Based on our results, the requirements for the SDR front end are derived.
用于辐射预一致性测量的直接转换SDR的性能改进
在这封信中,提出了一种高度线性的前端,以提高软件定义无线电(SDR)在辐射预一致性测量中的性能。在CISPR频带C/D中,测试接收器需要满足使用准峰值检测器的严格要求。通常,需要一个昂贵的预选滤波器组来对宽带瞬态进行完全兼容的测量。基于直接转换的SDRs在由谐波混合和饱和效应等原因引起的预一致性测量中显示出有限的开箱即用性能。通过使用三重平衡混频器,构建了高度线性的上变频级,消除了对滤波器组的需要。窄带中频滤波器大大降低了SDR的动态范围(DR)要求,使符合CISPR 16-1-1的测量成为可能。前端的灵敏度与市场上的专业接收器相当,尽管没有实现低噪声放大器。根据CISPR规范,通过连续波(CW)和瞬态信号验证了其性能。将宽带测量结果与使用压缩水平和噪声系数的DR的传统特征进行了比较。结果表明,可以通过CW测量来对符合设计的RF链路预算进行假设。基于我们的结果,推导出了SDR前端的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信