Questioning the appropriateness of sieving for processing indoor settled dust samples

L. Melymuk, S. Jílková, M. Kolář, Petra Svobodova, B. Vrana, K. Hilscherová
{"title":"Questioning the appropriateness of sieving for processing indoor settled dust samples","authors":"L. Melymuk, S. Jílková, M. Kolář, Petra Svobodova, B. Vrana, K. Hilscherová","doi":"10.20517/jeea.2022.12","DOIUrl":null,"url":null,"abstract":"Dust is a widely-used matrix for estimating human exposure to chemicals or as a screening tool for the identification of indoor chemicals of concern. As dust sampling became more common in exposure assessment, techniques used in processing soil have been adapted to dust samples, and separation of dust particles by sieving is common practice. However, there are no defined pore sizes, which results in inconsistent or difficult data interpretation and exposure estimates. Moreover, dust consists of more particle types than soil, particularly fibers, which behave differently during the sieving process. In this study, composite samples from seven microenvironments (homes, apartments, kindergartens, schools, public spaces, offices, and cars) were used to investigate the impact of the separation of dust by sieving on the observed chemical distributions. Dust was sieved to four particle size fractions (1-2 mm, 0.5-1 mm, 0.25-0.5 mm, and < 0.25 mm) and each fraction was analyzed for organic carbon content and polycyclic aromatic hydrocarbons (PAHs), and images of dust samples were taken by optical microscope. We identified irregular distributions across size fractions for carbon and PAHs as well as for fibrous particles. Based on the combination of chemical analyses and microscopy, we recommend careful consideration of pre-processing of dust samples to limit bias in dust exposure assessments, and sieving should be used only when necessary.","PeriodicalId":73738,"journal":{"name":"Journal of environmental exposure assessment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of environmental exposure assessment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20517/jeea.2022.12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Dust is a widely-used matrix for estimating human exposure to chemicals or as a screening tool for the identification of indoor chemicals of concern. As dust sampling became more common in exposure assessment, techniques used in processing soil have been adapted to dust samples, and separation of dust particles by sieving is common practice. However, there are no defined pore sizes, which results in inconsistent or difficult data interpretation and exposure estimates. Moreover, dust consists of more particle types than soil, particularly fibers, which behave differently during the sieving process. In this study, composite samples from seven microenvironments (homes, apartments, kindergartens, schools, public spaces, offices, and cars) were used to investigate the impact of the separation of dust by sieving on the observed chemical distributions. Dust was sieved to four particle size fractions (1-2 mm, 0.5-1 mm, 0.25-0.5 mm, and < 0.25 mm) and each fraction was analyzed for organic carbon content and polycyclic aromatic hydrocarbons (PAHs), and images of dust samples were taken by optical microscope. We identified irregular distributions across size fractions for carbon and PAHs as well as for fibrous particles. Based on the combination of chemical analyses and microscopy, we recommend careful consideration of pre-processing of dust samples to limit bias in dust exposure assessments, and sieving should be used only when necessary.
质疑筛分法处理室内尘埃样品的适宜性
粉尘是一种广泛使用的矩阵,用于估计人体对化学品的暴露,或作为识别室内化学品的筛选工具。随着粉尘取样在暴露评估中变得越来越普遍,土壤处理中使用的技术已经适应了粉尘样品,通过筛分分离粉尘颗粒是常见的做法。然而,由于没有明确的孔隙大小,这导致数据解释和暴露估计不一致或困难。此外,灰尘比土壤包含更多的颗粒类型,特别是纤维,它们在筛分过程中的表现不同。本研究采用七个微环境(家庭、公寓、幼儿园、学校、公共空间、办公室和汽车)的复合样本,研究了筛分粉尘对观察到的化学分布的影响。将粉尘筛分成1 ~ 2 mm、0.5 ~ 1 mm、0.25 ~ 0.5 mm和< 0.25 mm 4个粒径段,分析每个粒径段的有机碳含量和多环芳烃(PAHs)含量,并对粉尘样品进行光学显微镜成像。我们确定了碳和多环芳烃以及纤维颗粒在大小分数上的不规则分布。基于化学分析和显微镜的结合,我们建议仔细考虑粉尘样品的预处理,以限制粉尘暴露评估的偏差,并且只有在必要时才应使用筛分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信