The Thermal Manikin; a Useful and Effective Device for Evaluating Human Thermal Environments

T. Fukazawa, Y. Tochihara
{"title":"The Thermal Manikin; a Useful and Effective Device for Evaluating Human Thermal Environments","authors":"T. Fukazawa, Y. Tochihara","doi":"10.1618/JHES.18.021","DOIUrl":null,"url":null,"abstract":"Thermal manikin is a device, which simulates not only body shape but also human heat production and release. The device contributes to evaluate human heat transfer, thermal resistance of clothing, and protective tools for human safety with a high representativity. According to a study using the thermal manikin, for example, convective heat transfer from the human body has been found to be different in individual body location. The convective heat transfer coefficients in extremities are so larger than those in trunk and head that it is reasonable to put gloves on hands, e.g., to effectively protect the extremities from heat loss in a cold. In natural convection system, it has been experimentally confirmed through the thermal manikin that the convective heat transfer coefficient decreases with decrease in ambient pressure. Therefore, during exposure to a low ambient pressure, even if in a cold, temperature drop in skin surface can be suppressed because of the depressed sympathetic nerve activity and of the decrease in the convective heat transfer coefficient. A baby thermal manikin aged 0.5 year-old has been originally developed with aiming for infant’s safety and thermal comfort. There is a significant difference in convective heat transfer in the whole body between infant and adult because of difference in height; the coefficient is larger in infant than in adult. The baby thermal manikin has been employed for measuring the thermal resistance of clothings for infant. An estimation equation by means of the total weight of the clothing for infant has been derived to obtain the thermal resistance, because a high correlation has been confirmed between them.","PeriodicalId":89177,"journal":{"name":"Journal of the human-environment system","volume":"18 1","pages":"021-028"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1618/JHES.18.021","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the human-environment system","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1618/JHES.18.021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Thermal manikin is a device, which simulates not only body shape but also human heat production and release. The device contributes to evaluate human heat transfer, thermal resistance of clothing, and protective tools for human safety with a high representativity. According to a study using the thermal manikin, for example, convective heat transfer from the human body has been found to be different in individual body location. The convective heat transfer coefficients in extremities are so larger than those in trunk and head that it is reasonable to put gloves on hands, e.g., to effectively protect the extremities from heat loss in a cold. In natural convection system, it has been experimentally confirmed through the thermal manikin that the convective heat transfer coefficient decreases with decrease in ambient pressure. Therefore, during exposure to a low ambient pressure, even if in a cold, temperature drop in skin surface can be suppressed because of the depressed sympathetic nerve activity and of the decrease in the convective heat transfer coefficient. A baby thermal manikin aged 0.5 year-old has been originally developed with aiming for infant’s safety and thermal comfort. There is a significant difference in convective heat transfer in the whole body between infant and adult because of difference in height; the coefficient is larger in infant than in adult. The baby thermal manikin has been employed for measuring the thermal resistance of clothings for infant. An estimation equation by means of the total weight of the clothing for infant has been derived to obtain the thermal resistance, because a high correlation has been confirmed between them.
热人体模型;一种实用有效的人体热环境评价装置
热人体模型是一种既能模拟人体形态又能模拟人体热量产生和释放的装置。该设备有助于评估人体传热,服装热阻和人体安全防护工具,具有很高的代表性。例如,一项使用热人体模型的研究发现,人体的对流传热在不同的身体部位是不同的。四肢的对流换热系数比躯干和头部的对流换热系数大得多,因此戴上手套是合理的,例如,在寒冷的天气里,可以有效地保护四肢免受热量的损失。在自然对流系统中,通过热模型实验证实了对流换热系数随环境压力的降低而减小。因此,在暴露于低环境压力时,即使在寒冷的环境中,由于交感神经活动的抑制和对流换热系数的降低,皮肤表面的温度下降也可以被抑制。一款0.5岁的婴儿热人体模型最初是为了婴儿的安全和热舒适而开发的。由于身高的差异,婴儿与成人全身对流换热有显著差异;婴儿的系数大于成人。该婴儿热人体模型用于测量婴儿服装的热阻。由于热阻与婴儿服装总重之间存在较高的相关性,推导出了用婴儿服装总重计算热阻的公式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书