Implant Surface Design Regulates Mesenchymal Stem Cell Differentiation and Maturation

Q1 Medicine
B. Boyan, A. Cheng, R. Olivares-Navarrete, Z. Schwartz
{"title":"Implant Surface Design Regulates Mesenchymal Stem Cell Differentiation and Maturation","authors":"B. Boyan, A. Cheng, R. Olivares-Navarrete, Z. Schwartz","doi":"10.1177/0022034515624444","DOIUrl":null,"url":null,"abstract":"Changes in dental implant materials, structural design, and surface properties can all affect biological response. While bulk properties are important for mechanical stability of the implant, surface design ultimately contributes to osseointegration. This article reviews the surface parameters of dental implant materials that contribute to improved cell response and osseointegration. In particular, we focus on how surface design affects mesenchymal cell response and differentiation into the osteoblast lineage. Surface roughness has been largely studied at the microscale, but recent studies have highlighted the importance of hierarchical micron/submicron/nanosurface roughness, as well as surface roughness in combination with surface wettability. Integrins are transmembrane receptors that recognize changes in the surface and mediate downstream signaling pathways. Specifically, the noncanonical Wnt5a pathway has been implicated in osteoblastic differentiation of cells on titanium implant surfaces. However, much remains to be elucidated. Only recently have studies been conducted on the differences in biological response to implants based on sex, age, and clinical factors; these all point toward differences that advocate for patient-specific implant design. Finally, challenges in implant surface characterization must be addressed to optimize and compare data across studies. An understanding of both the science and the biology of the materials is crucial for developing novel dental implant materials and surface modifications for improved osseointegration.","PeriodicalId":7300,"journal":{"name":"Advances in Dental Research","volume":"28 1","pages":"10 - 17"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/0022034515624444","citationCount":"57","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/0022034515624444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 57

Abstract

Changes in dental implant materials, structural design, and surface properties can all affect biological response. While bulk properties are important for mechanical stability of the implant, surface design ultimately contributes to osseointegration. This article reviews the surface parameters of dental implant materials that contribute to improved cell response and osseointegration. In particular, we focus on how surface design affects mesenchymal cell response and differentiation into the osteoblast lineage. Surface roughness has been largely studied at the microscale, but recent studies have highlighted the importance of hierarchical micron/submicron/nanosurface roughness, as well as surface roughness in combination with surface wettability. Integrins are transmembrane receptors that recognize changes in the surface and mediate downstream signaling pathways. Specifically, the noncanonical Wnt5a pathway has been implicated in osteoblastic differentiation of cells on titanium implant surfaces. However, much remains to be elucidated. Only recently have studies been conducted on the differences in biological response to implants based on sex, age, and clinical factors; these all point toward differences that advocate for patient-specific implant design. Finally, challenges in implant surface characterization must be addressed to optimize and compare data across studies. An understanding of both the science and the biology of the materials is crucial for developing novel dental implant materials and surface modifications for improved osseointegration.
植入物表面设计调节间充质干细胞分化和成熟
牙种植体材料、结构设计和表面特性的变化都会影响生物反应。虽然体积特性对种植体的机械稳定性很重要,但表面设计最终有助于骨整合。本文综述了有助于改善细胞反应和骨整合的牙种植材料的表面参数。我们特别关注表面设计如何影响间充质细胞的反应和向成骨细胞谱系的分化。表面粗糙度主要在微观尺度上进行研究,但最近的研究强调了分层微米/亚微米/纳米表面粗糙度的重要性,以及表面粗糙度与表面润湿性的结合。整合素是一种跨膜受体,可识别表面变化并介导下游信号通路。具体来说,非典型的Wnt5a通路与钛种植体表面细胞的成骨细胞分化有关。然而,仍有许多问题有待阐明。直到最近才对基于性别、年龄和临床因素的植入物的生物反应差异进行了研究;这些都指向了主张针对患者的植入物设计的差异。最后,必须解决种植体表面表征方面的挑战,以优化和比较研究中的数据。对材料的科学和生物学的理解对于开发新型牙种植材料和改善骨整合的表面修饰至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Advances in Dental Research
Advances in Dental Research Medicine-Medicine (all)
CiteScore
8.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信