{"title":"Multislice spiral computed tomography of an orthotopic severe combined immunodeficient mouse model for lung adenocarcinoma","authors":"Katharina Marten ,&nbsp;Frauke Alves ,&nbsp;Tim Feuerstein ,&nbsp;Matthias Funke ,&nbsp;Christoph Engelke ,&nbsp;Lutz F. Tietze ,&nbsp;Klaus Nebendahl ,&nbsp;Lorenz Trümper ,&nbsp;Christiane Jakob ,&nbsp;Eckhardt Grabbe","doi":"10.1016/S0939-8600(03)80001-9","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aim:</h3><p>In recent years, much research interest has been rightfully directed towards modelling human disease. The increasing demand of laboratory animals has led to a major impetus in small animal imaging. We evaluated the feasibility of using multislice spiral CT (MSCT) technology in a severe combined immunodeficiency (SCID) mouse model for non-small cell lung cancer.</p></div><div><h3>Materials and Methods:</h3><p>Mice (n = 14) were implanted orthotopically with the human non-small cell lung adenocarcinoma cell line A 549. Mice were scanned with MSCT and sacrificed 7 days (n = 3), 14 days (n = 3), and 21 days (n = 5) after tumor cell implantation, respectively. Histopathology was performed. Tumor size as revealed by imaging and pathology was correlated. A group of animals (n = 3) received anti-cancer treatment with seco-CBI-Q-galatoside. Those mice were scanned with MSCT 21 days after tumor implantation and sacrificed, and histopathologic work-up was performed.</p></div><div><h3>Results:</h3><p>A total of 14 mice with 14 macroscopically visible and 5 microscopically appreciable adenocarcinomas of the lung were examined. All macroscopically visible tumors were readily depicted with MSCT except from 2 lesions of 1 mm in diameter. MSCT accurately displayed the different tumor sizes in treated vs. non-treated animals.</p></div><div><h3>Discussion:</h3><p>MSCT proved to be a valuable tool for imaging of a murine lung cancer model. This evidences a potential use of this technology in small animal lung cancer imaging.</p></div>","PeriodicalId":77206,"journal":{"name":"Journal of experimental animal science","volume":"42 4","pages":"Pages 181-191"},"PeriodicalIF":0.0000,"publicationDate":"2003-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0939-8600(03)80001-9","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of experimental animal science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0939860003800019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Aim:

In recent years, much research interest has been rightfully directed towards modelling human disease. The increasing demand of laboratory animals has led to a major impetus in small animal imaging. We evaluated the feasibility of using multislice spiral CT (MSCT) technology in a severe combined immunodeficiency (SCID) mouse model for non-small cell lung cancer.

Materials and Methods:

Mice (n = 14) were implanted orthotopically with the human non-small cell lung adenocarcinoma cell line A 549. Mice were scanned with MSCT and sacrificed 7 days (n = 3), 14 days (n = 3), and 21 days (n = 5) after tumor cell implantation, respectively. Histopathology was performed. Tumor size as revealed by imaging and pathology was correlated. A group of animals (n = 3) received anti-cancer treatment with seco-CBI-Q-galatoside. Those mice were scanned with MSCT 21 days after tumor implantation and sacrificed, and histopathologic work-up was performed.

Results:

A total of 14 mice with 14 macroscopically visible and 5 microscopically appreciable adenocarcinomas of the lung were examined. All macroscopically visible tumors were readily depicted with MSCT except from 2 lesions of 1 mm in diameter. MSCT accurately displayed the different tumor sizes in treated vs. non-treated animals.

Discussion:

MSCT proved to be a valuable tool for imaging of a murine lung cancer model. This evidences a potential use of this technology in small animal lung cancer imaging.

原位严重联合免疫缺陷小鼠肺腺癌模型的多层螺旋计算机断层扫描
背景和目的:近年来,许多研究兴趣已经正确地指向模拟人类疾病。对实验动物的需求不断增加,导致了小动物成像的主要推动力。我们评估了多层螺旋CT (MSCT)技术在严重联合免疫缺陷(SCID)小鼠非小细胞肺癌模型中的可行性。材料与方法:将人非小细胞肺腺癌细胞a549原位植入小鼠(n = 14)。小鼠分别在肿瘤细胞植入后第7天(n = 3)、第14天(n = 3)和第21天(n = 5)行MSCT扫描和处死。进行组织病理学检查。影像与病理显示肿瘤大小相关。一组动物(n = 3)接受二甲半糖苷抗癌治疗。肿瘤植入21天后,采用MSCT扫描处死小鼠,并进行组织病理学检查。结果:共检查14只小鼠,显微镜下可见肺腺癌14个,显微镜下可见肺腺癌5个。除了2个直径为1mm的病变外,所有肉眼可见的肿瘤都很容易用MSCT描绘出来。MSCT准确显示了治疗组与未治疗组的不同肿瘤大小。讨论:MSCT被证明是小鼠肺癌模型成像的一种有价值的工具。这证明了该技术在小动物肺癌成像中的潜在应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信