Retrospective study of two fixation methods for 4-corner fusion: Shape-memory staple vs. dorsal circular plate

A. Le Corre, L. Ardouin, T. Loubersac, E. Gaisne, P. Bellemère
{"title":"Retrospective study of two fixation methods for 4-corner fusion: Shape-memory staple vs. dorsal circular plate","authors":"A. Le Corre,&nbsp;L. Ardouin,&nbsp;T. Loubersac,&nbsp;E. Gaisne,&nbsp;P. Bellemère","doi":"10.1016/j.main.2015.08.008","DOIUrl":null,"url":null,"abstract":"<div><p>The purpose of this study was to compare the results of two groups of patients with four-corner fusion, one group fixed with shape-memory staples and the other with locked circular plates. This retrospective study compared 52 wrists operated for scaphoid excision and four-corner fusion between 2005 and 2011. The arthrodesis was ensured by a shape-memory quadripodal staple (4Fusion<sup>®</sup>, Memometal™) in 37 cases and a locking dorsal circular plate (Xpode<sup>®</sup>, Biotech Ortho™) in 15 cases. In the staple group, the mean age was 58.5 years and the average follow-up was 4.3 years. In the circular plate group, the mean age was 58.6 years and the average follow-up was 3.1 years. Pain, range of motion, grip strength, functional scores (QuickDASH and PWRE), fusion of the midcarpal joint, complications (implant fracture and reoperation) and patients’ satisfaction were used as outcome measures. There was no pain in 43% of patients in the staple group and 40% of patients in the circular plate group at the follow-up; range of motion and functional scores were similar in both groups. Seventy-five percent of patients in the staple group were satisfied or very satisfied versus 60% in the circular plate group. The implant broke in 24.3% of cases in the staple group and 60% in the circular plate group. Reoperation was needed in 18% of the staple cases and 14% of the plate cases. There was no difference between the implants in terms of pain, range of motion, functional scores and patient satisfactory. The implant fracture rate in the plate group was high. This study brings into question implant reliability for the four-corner fusion procedure.</p></div>","PeriodicalId":50699,"journal":{"name":"Chirurgie De La Main","volume":"34 6","pages":"Pages 300-306"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.main.2015.08.008","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirurgie De La Main","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1297320315001341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

The purpose of this study was to compare the results of two groups of patients with four-corner fusion, one group fixed with shape-memory staples and the other with locked circular plates. This retrospective study compared 52 wrists operated for scaphoid excision and four-corner fusion between 2005 and 2011. The arthrodesis was ensured by a shape-memory quadripodal staple (4Fusion®, Memometal™) in 37 cases and a locking dorsal circular plate (Xpode®, Biotech Ortho™) in 15 cases. In the staple group, the mean age was 58.5 years and the average follow-up was 4.3 years. In the circular plate group, the mean age was 58.6 years and the average follow-up was 3.1 years. Pain, range of motion, grip strength, functional scores (QuickDASH and PWRE), fusion of the midcarpal joint, complications (implant fracture and reoperation) and patients’ satisfaction were used as outcome measures. There was no pain in 43% of patients in the staple group and 40% of patients in the circular plate group at the follow-up; range of motion and functional scores were similar in both groups. Seventy-five percent of patients in the staple group were satisfied or very satisfied versus 60% in the circular plate group. The implant broke in 24.3% of cases in the staple group and 60% in the circular plate group. Reoperation was needed in 18% of the staple cases and 14% of the plate cases. There was no difference between the implants in terms of pain, range of motion, functional scores and patient satisfactory. The implant fracture rate in the plate group was high. This study brings into question implant reliability for the four-corner fusion procedure.

四角融合术两种固定方法的回顾性研究:形状记忆钉与背侧圆形钢板
本研究的目的是比较两组患者进行四角融合的结果,一组使用形状记忆钉固定,另一组使用锁定圆形钢板固定。本回顾性研究比较了2005年至2011年间进行舟状骨切除和四角融合术的52例腕关节。37例采用形状记忆四足钉(4Fusion®,memmetal™),15例采用锁定背侧圆形钢板(Xpode®,Biotech Ortho™)。主食组患者平均年龄58.5岁,平均随访时间4.3年。圆形钢板组平均年龄58.6岁,平均随访3.1年。以疼痛、活动范围、握力、功能评分(QuickDASH和PWRE)、腕中关节融合、并发症(假体骨折和再手术)和患者满意度作为结局指标。随访时,钉钉组43%的患者无疼痛,环形钢板组40%的患者无疼痛;两组的活动范围和功能评分相似。钉钉组中75%的患者满意或非常满意,而圆板组中为60%。钉钉组和圆钢板组的假体断裂率分别为24.3%和60%。18%的钉钉病例和14%的钢板病例需要再次手术。两种植入物在疼痛、活动范围、功能评分和患者满意度方面没有差异。钢板组内种植体骨折率较高。本研究对种植体在四角融合手术中的可靠性提出了质疑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Chirurgie De La Main
Chirurgie De La Main 医学-外科
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信