A Novel and Quantitative Detection Assay (effluxR) for Identifying Efflux-Associated Resistance Genes Using Multiplex Digital PCR in Clinical Isolates of Pseudomonas aeruginosa.

IF 2.3 Q3 BIOCHEMICAL RESEARCH METHODS
Nontaporn Rattanachak, Sattaporn Weawsiangsang, Robert A Baldock, Theerasak Jaifoo, Touchkanin Jongjitvimol, Jirapas Jongjitwimol
{"title":"A Novel and Quantitative Detection Assay (<i>effluxR</i>) for Identifying Efflux-Associated Resistance Genes Using Multiplex Digital PCR in Clinical Isolates of <i>Pseudomonas aeruginosa</i>.","authors":"Nontaporn Rattanachak,&nbsp;Sattaporn Weawsiangsang,&nbsp;Robert A Baldock,&nbsp;Theerasak Jaifoo,&nbsp;Touchkanin Jongjitvimol,&nbsp;Jirapas Jongjitwimol","doi":"10.3390/mps6050096","DOIUrl":null,"url":null,"abstract":"<p><p>The rise of multidrug resistance of <i>Pseudomonas aeruginosa</i> highlights an increased need for selective and precise antimicrobial treatment. Drug efflux pumps are one of the major mechanisms of antimicrobial resistance found in many bacteria, including <i>P</i>. <i>aeruginosa</i>. Detection of efflux genes using a polymerase chain reaction (PCR)-based system would enable resistance detection and aid clinical decision making. Therefore, we aimed to develop and optimize a novel method herein referred to as \"<i>effluxR</i> detection assay\" using multiplex digital PCR (mdPCR) for detection of <i>mex</i> efflux pump genes in <i>P. aeruginosa</i> strains. The annealing/extension temperatures and gDNA concentrations were optimized to amplify <i>mexB</i>, <i>mexD</i>, and <i>mexY</i> using the multiplex quantitative PCR (mqPCR) system. We established the optimal mqPCR conditions for the assay (Ta of 59 °C with gDNA concentrations at or above 0.5 ng/µL). Using these conditions, we were able to successfully detect the presence of these genes in a quantity-dependent manner. The limit of detection for <i>mex</i> genes using the <i>effluxR</i> detection assay with mdPCR was 0.001 ng/µL (7.04-34.81 copies/µL). Moreover, using blind sample testing, we show that <i>effluxR</i> detection assay had 100% sensitivity and specificity for detecting <i>mex</i> genes in <i>P</i>. <i>aeruginosa</i>. In conclusion, the <i>effluxR</i> detection assay, using mdPCR, is able to identify the presence of multiple <i>mex</i> genes in <i>P</i>. <i>aeruginosa</i> that may aid clinical laboratory decisions and further epidemiological studies.</p>","PeriodicalId":18715,"journal":{"name":"Methods and Protocols","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10608825/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/mps6050096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The rise of multidrug resistance of Pseudomonas aeruginosa highlights an increased need for selective and precise antimicrobial treatment. Drug efflux pumps are one of the major mechanisms of antimicrobial resistance found in many bacteria, including P. aeruginosa. Detection of efflux genes using a polymerase chain reaction (PCR)-based system would enable resistance detection and aid clinical decision making. Therefore, we aimed to develop and optimize a novel method herein referred to as "effluxR detection assay" using multiplex digital PCR (mdPCR) for detection of mex efflux pump genes in P. aeruginosa strains. The annealing/extension temperatures and gDNA concentrations were optimized to amplify mexB, mexD, and mexY using the multiplex quantitative PCR (mqPCR) system. We established the optimal mqPCR conditions for the assay (Ta of 59 °C with gDNA concentrations at or above 0.5 ng/µL). Using these conditions, we were able to successfully detect the presence of these genes in a quantity-dependent manner. The limit of detection for mex genes using the effluxR detection assay with mdPCR was 0.001 ng/µL (7.04-34.81 copies/µL). Moreover, using blind sample testing, we show that effluxR detection assay had 100% sensitivity and specificity for detecting mex genes in P. aeruginosa. In conclusion, the effluxR detection assay, using mdPCR, is able to identify the presence of multiple mex genes in P. aeruginosa that may aid clinical laboratory decisions and further epidemiological studies.

Abstract Image

Abstract Image

Abstract Image

一种新的定量检测方法(effluxR),用于在铜绿假单胞菌临床分离株中使用多重数字PCR鉴定与流出相关的耐药性基因。
铜绿假单胞菌多药耐药性的增加凸显了对选择性和精确抗菌治疗的需求增加。药物外排泵是在包括铜绿假单胞菌在内的许多细菌中发现的抗微生物耐药性的主要机制之一。使用基于聚合酶链式反应(PCR)的系统检测外排基因将能够进行耐药性检测并有助于临床决策。因此,我们旨在开发和优化一种新的方法,称为“effluxR检测法”,使用多重数字PCR(mdPCR)检测铜绿假单胞菌中的mex外排泵基因。使用多重定量PCR(mqPCR)系统优化退火/延伸温度和gDNA浓度以扩增mexB、mexD和mexY。我们建立了测定的最佳mqPCR条件(Ta为59°C,gDNA浓度为或高于0.5纳克/µL)。利用这些条件,我们能够以数量依赖的方式成功地检测到这些基因的存在。使用带mdPCR的effluxR检测法对mex基因的检测限为0.001纳克/µL(7.04-34.81拷贝/µL)。此外,通过盲样检测,我们发现effluxR检测法对检测铜绿假单胞菌中的mex基因具有100%的敏感性和特异性。总之,使用mdPCR的effluxR检测方法能够识别铜绿假单胞菌中多个mex基因的存在,这可能有助于临床实验室的决策和进一步的流行病学研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Methods and Protocols
Methods and Protocols Biochemistry, Genetics and Molecular Biology-Biochemistry, Genetics and Molecular Biology (miscellaneous)
CiteScore
3.60
自引率
0.00%
发文量
85
审稿时长
8 weeks
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信