Analysis of drug of abuse compounds using passive sampling and ultrahigh-liquid chromatography coupled to mass spectrometry.

IF 1.9 4区 环境科学与生态学 Q4 ENGINEERING, ENVIRONMENTAL
Carolina A Jiménez-Rojas, Carlos Emilio Gutiérrez Ulloa, Sandra M Chingaté-López, Jaime A Lara-Borrero
{"title":"Analysis of drug of abuse compounds using passive sampling and ultrahigh-liquid chromatography coupled to mass spectrometry.","authors":"Carolina A Jiménez-Rojas, Carlos Emilio Gutiérrez Ulloa, Sandra M Chingaté-López, Jaime A Lara-Borrero","doi":"10.1080/10934529.2023.2266327","DOIUrl":null,"url":null,"abstract":"<p><p>The present study proposes the monitoring of compounds of drugs of abuse through the use of passive samplers in water systems. Initially, four positive ion compounds of interest were determined according to national surveys, and then composite sampling and passive sampling were implemented using continuous-flow passive samplers containing two types of sorbents, the Empore disk and Gerstel Twister. Two study sites were established at the beginning and at the end of the middle Bogotá River basin. After 4 days, the sorbents were removed so that they could be desorbed and analyzed using UHPLC-MS in the laboratory. For the composite samples, the results were below the first calibration curve point (FCCP) of the chromatographic method, and for passive sampling, peaks of benzoylecgonine (BE) (21427.3 pg mL<sup>-1</sup>), methamphetamine (MET) (67101.5 pg mL<sup>-1</sup>), MDMA (ecstasy) (225844.8 pg mL<sup>-1</sup>) and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) (15908.4 pg mL<sup>-1</sup>) were found. Therefore, passive sampling could be suggested as an alternative to composite sampling for the monitoring of compounds.</p>","PeriodicalId":15671,"journal":{"name":"Journal of Environmental Science and Health Part A-toxic\\/hazardous Substances & Environmental Engineering","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Science and Health Part A-toxic\\/hazardous Substances & Environmental Engineering","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/10934529.2023.2266327","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/10 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

The present study proposes the monitoring of compounds of drugs of abuse through the use of passive samplers in water systems. Initially, four positive ion compounds of interest were determined according to national surveys, and then composite sampling and passive sampling were implemented using continuous-flow passive samplers containing two types of sorbents, the Empore disk and Gerstel Twister. Two study sites were established at the beginning and at the end of the middle Bogotá River basin. After 4 days, the sorbents were removed so that they could be desorbed and analyzed using UHPLC-MS in the laboratory. For the composite samples, the results were below the first calibration curve point (FCCP) of the chromatographic method, and for passive sampling, peaks of benzoylecgonine (BE) (21427.3 pg mL-1), methamphetamine (MET) (67101.5 pg mL-1), MDMA (ecstasy) (225844.8 pg mL-1) and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) (15908.4 pg mL-1) were found. Therefore, passive sampling could be suggested as an alternative to composite sampling for the monitoring of compounds.

使用被动采样和超高液相色谱-质谱联用分析药物滥用化合物。
本研究建议通过在水系统中使用被动采样器来监测滥用药物的化合物。最初,根据国家调查确定了四种感兴趣的正离子化合物,然后使用含有两种吸附剂的连续流被动采样器(Empore disk和Gerstel Twister)进行复合采样和被动采样。波哥大河流域中部的起点和终点分别建立了两个研究点。4之后 天,除去吸附剂,以便可以在实验室中使用UHPLC-MS对其进行解吸和分析。对于复合样品,结果低于色谱法的第一个校准曲线点(FCCP),而对于被动采样,苯甲酰胆碱(BE)的峰值(21427.3 pg mL-1)、甲基苯丙胺(MET)(67101.5 pg mL-1)、摇头丸(摇头丸)(225844.8 pg mL-1)和2-亚乙基-1,5-二甲基-3,3-二苯基吡咯烷(EDDP)(15908.4 pg mL-1)。因此,可以建议将被动采样作为监测化合物的复合采样的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
4.80%
发文量
93
审稿时长
3.0 months
期刊介绍: 14 issues per year Abstracted/indexed in: BioSciences Information Service of Biological Abstracts (BIOSIS), CAB ABSTRACTS, CEABA, Chemical Abstracts & Chemical Safety NewsBase, Current Contents/Agriculture, Biology, and Environmental Sciences, Elsevier BIOBASE/Current Awareness in Biological Sciences, EMBASE/Excerpta Medica, Engineering Index/COMPENDEX PLUS, Environment Abstracts, Environmental Periodicals Bibliography & INIST-Pascal/CNRS, National Agriculture Library-AGRICOLA, NIOSHTIC & Pollution Abstracts, PubSCIENCE, Reference Update, Research Alert & Science Citation Index Expanded (SCIE), Water Resources Abstracts and Index Medicus/MEDLINE.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信