Low-dimensional data-based surrogate model of a continuum-mechanical musculoskeletal system based on non-intrusive model order reduction

IF 2.2 3区 工程技术 Q2 MECHANICS
Jonas Kneifl, David Rosin, Okan Avci, Oliver Röhrle, Jörg Fehr
{"title":"Low-dimensional data-based surrogate model of a continuum-mechanical musculoskeletal system based on non-intrusive model order reduction","authors":"Jonas Kneifl,&nbsp;David Rosin,&nbsp;Okan Avci,&nbsp;Oliver Röhrle,&nbsp;Jörg Fehr","doi":"10.1007/s00419-023-02458-5","DOIUrl":null,"url":null,"abstract":"<div><p>Over the last decades, computer modeling has evolved from a supporting tool for engineering prototype design to an ubiquitous instrument in non-traditional fields such as medical rehabilitation. This area comes with unique challenges, e.g. the complex modeling of soft tissue or the analysis of musculoskeletal systems. Conventional modeling approaches like the finite element (FE) method are computationally costly when dealing with such models, limiting their usability for real-time simulation or deployment on low-end hardware, if the model at hand cannot be simplified without losing its expressiveness. Non-traditional approaches such as surrogate modeling using data-driven model order reduction are used to make complex high-fidelity models more widely available regardless. They often involve a dimensionality reduction step, in which the high-dimensional system state is transformed onto a low-dimensional subspace or manifold, and a regression approach to capture the reduced system behavior. While most publications focus on one dimensionality reduction, such as principal component analysis (PCA) (linear) or autoencoder (nonlinear), we consider and compare PCA, kernel PCA, autoencoders, as well as variational autoencoders for the approximation of a continuum-mechanical system. In detail, we demonstrate the benefits of the surrogate modeling approach on a complex musculoskeletal system of a human upper-arm with severe nonlinearities and physiological geometry. We consider both, the model’s deformation and the internal stress as the two main quantities of interest in a FE context. By doing so we are able to create computationally low-cost surrogate models which capture the system behavior with high approximation quality and fast evaluations.</p></div>","PeriodicalId":477,"journal":{"name":"Archive of Applied Mechanics","volume":"93 9","pages":"3637 - 3663"},"PeriodicalIF":2.2000,"publicationDate":"2023-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s00419-023-02458-5.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archive of Applied Mechanics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00419-023-02458-5","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 3

Abstract

Over the last decades, computer modeling has evolved from a supporting tool for engineering prototype design to an ubiquitous instrument in non-traditional fields such as medical rehabilitation. This area comes with unique challenges, e.g. the complex modeling of soft tissue or the analysis of musculoskeletal systems. Conventional modeling approaches like the finite element (FE) method are computationally costly when dealing with such models, limiting their usability for real-time simulation or deployment on low-end hardware, if the model at hand cannot be simplified without losing its expressiveness. Non-traditional approaches such as surrogate modeling using data-driven model order reduction are used to make complex high-fidelity models more widely available regardless. They often involve a dimensionality reduction step, in which the high-dimensional system state is transformed onto a low-dimensional subspace or manifold, and a regression approach to capture the reduced system behavior. While most publications focus on one dimensionality reduction, such as principal component analysis (PCA) (linear) or autoencoder (nonlinear), we consider and compare PCA, kernel PCA, autoencoders, as well as variational autoencoders for the approximation of a continuum-mechanical system. In detail, we demonstrate the benefits of the surrogate modeling approach on a complex musculoskeletal system of a human upper-arm with severe nonlinearities and physiological geometry. We consider both, the model’s deformation and the internal stress as the two main quantities of interest in a FE context. By doing so we are able to create computationally low-cost surrogate models which capture the system behavior with high approximation quality and fast evaluations.

Abstract Image

基于非侵入式模型阶数约简的连续机械肌肉骨骼系统低维数据代理模型
在过去的几十年里,计算机建模已经从工程原型设计的辅助工具发展成为医疗康复等非传统领域中无处不在的工具。这一领域面临着独特的挑战,例如软组织的复杂建模或肌肉骨骼系统的分析。传统的建模方法,如有限元(FE)方法,在处理这些模型时计算成本很高,如果手头的模型不能在不失去其表达性的情况下进行简化,则限制了它们在实时仿真或低端硬件上部署的可用性。非传统的方法,例如使用数据驱动模型降阶的代理建模,可以使复杂的高保真模型更广泛地可用。它们通常涉及降维步骤,其中高维系统状态转换为低维子空间或流形,并采用回归方法捕获降维后的系统行为。虽然大多数出版物关注一维降维,如主成分分析(PCA)(线性)或自编码器(非线性),但我们考虑并比较了主成分分析、核主成分分析、自编码器以及变分自编码器对连续机械系统的逼近。详细地说,我们展示了替代建模方法对具有严重非线性和生理几何的人类上臂复杂肌肉骨骼系统的好处。我们认为模型的变形和内应力是有限元环境中两个主要的感兴趣的量。通过这样做,我们能够创建计算成本低的代理模型,以高近似质量和快速评估捕获系统行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.40
自引率
10.70%
发文量
234
审稿时长
4-8 weeks
期刊介绍: Archive of Applied Mechanics serves as a platform to communicate original research of scholarly value in all branches of theoretical and applied mechanics, i.e., in solid and fluid mechanics, dynamics and vibrations. It focuses on continuum mechanics in general, structural mechanics, biomechanics, micro- and nano-mechanics as well as hydrodynamics. In particular, the following topics are emphasised: thermodynamics of materials, material modeling, multi-physics, mechanical properties of materials, homogenisation, phase transitions, fracture and damage mechanics, vibration, wave propagation experimental mechanics as well as machine learning techniques in the context of applied mechanics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信