External Auditory Canal: Computed Tomography Analysis and Classification.

IF 1 Q3 OTORHINOLARYNGOLOGY
International Archives of Otorhinolaryngology Pub Date : 2023-09-19 eCollection Date: 2023-10-01 DOI:10.1055/s-0042-1758213
Mohammad Waheed El-Anwar, Yasser Ahmed Fouad, Ahmed Fouad Elgohary, Sameh Saber, Mohamed Adel Mobasher
{"title":"External Auditory Canal: Computed Tomography Analysis and Classification.","authors":"Mohammad Waheed El-Anwar,&nbsp;Yasser Ahmed Fouad,&nbsp;Ahmed Fouad Elgohary,&nbsp;Sameh Saber,&nbsp;Mohamed Adel Mobasher","doi":"10.1055/s-0042-1758213","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>  Computed tomography (CT) details of the external auditory canal (EAC) are not fully covered in the literature, so building up base for the CT evaluation and description is important. Preoperative details of the EAC are mandatory before any approach or procedure involving the canal. <b>Objective</b>  To determine the different dimensions, measurements, and grading of the EAC by CT scan that were not previously published. <b>Methods</b>  The CT scans of 100 temporal bones (200 sides) were included. Axial images were acquired with multiplanar reformates to obtain delicate details in coronal and sagittal planes for all subjects. <b>Results</b>  At the EAC entry, the mean vertical length (height) was 7.75 ± 1 mm, and its mean horizontal length (width) was 6.1 ± 0.8. At the bony cartilaginous junction of the EAC, the mean vertical length was 7.88 ± 1 mm, and its mean horizontal length was 6.22 ± 0.9. At the EAC isthmus, the mean vertical length was 6.8 ± 0.97 mm, and its mean horizontal length was 5.2 ± 0.76. At the medial end of the EAC, the mean vertical length was 7.1 ± 0.9 mm, and its mean horizontal length was 5.4 ± 0.85. There were no reported significant differences between right and left sides in all dimensions. Males showed significantly longer vertical and horizontal dimensions of the EAC entry, vertical dimension of the isthmus, and vertical dimension of the medial end of the EAC than females. <b>Conclusion</b>  This study improves otologists and radiologists' awareness of EAC variations in the ear field and can be of help to residents in training.</p>","PeriodicalId":13731,"journal":{"name":"International Archives of Otorhinolaryngology","volume":"27 4","pages":"e565-e570"},"PeriodicalIF":1.0000,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/63/4b/10-1055-s-0042-1758213.PMC10593536.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Archives of Otorhinolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1758213","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction  Computed tomography (CT) details of the external auditory canal (EAC) are not fully covered in the literature, so building up base for the CT evaluation and description is important. Preoperative details of the EAC are mandatory before any approach or procedure involving the canal. Objective  To determine the different dimensions, measurements, and grading of the EAC by CT scan that were not previously published. Methods  The CT scans of 100 temporal bones (200 sides) were included. Axial images were acquired with multiplanar reformates to obtain delicate details in coronal and sagittal planes for all subjects. Results  At the EAC entry, the mean vertical length (height) was 7.75 ± 1 mm, and its mean horizontal length (width) was 6.1 ± 0.8. At the bony cartilaginous junction of the EAC, the mean vertical length was 7.88 ± 1 mm, and its mean horizontal length was 6.22 ± 0.9. At the EAC isthmus, the mean vertical length was 6.8 ± 0.97 mm, and its mean horizontal length was 5.2 ± 0.76. At the medial end of the EAC, the mean vertical length was 7.1 ± 0.9 mm, and its mean horizontal length was 5.4 ± 0.85. There were no reported significant differences between right and left sides in all dimensions. Males showed significantly longer vertical and horizontal dimensions of the EAC entry, vertical dimension of the isthmus, and vertical dimension of the medial end of the EAC than females. Conclusion  This study improves otologists and radiologists' awareness of EAC variations in the ear field and can be of help to residents in training.

Abstract Image

Abstract Image

外耳道:计算机断层扫描分析与分类。
介绍 外耳道的计算机断层扫描(CT)细节在文献中没有完全涵盖,因此为CT评估和描述奠定基础很重要。在任何涉及运河的方法或程序之前,必须提供EAC的术前详细信息。客观的 通过CT扫描确定EAC的不同尺寸、测量和分级,这些都是以前没有发表的。方法 包括100块颞骨(200侧)的CT扫描。轴位图像采用多平面重新格式化获得,以获得所有受试者在冠状面和矢状面上的精细细节。后果 EAC入口的平均垂直长度(高度)为7.75 ± 1. mm,其平均水平长度(宽度)为6.1 ± 0.8.在EAC的骨软骨交界处,平均垂直长度为7.88 ± 1. mm,其平均水平长度为6.22 ± 0.9.在东非共同体地峡,平均垂直长度为6.8 ± 0.97 mm,其平均水平长度为5.2 ± 0.76。在EAC的内侧端,平均垂直长度为7.1 ± 0.9 mm,平均水平长度为5.4 ± 0.85。据报道,左右两侧在所有维度上都没有显著差异。男性EAC入口的垂直和水平尺寸、峡部的垂直尺寸和EAC内侧端的垂直尺寸明显长于女性。结论 这项研究提高了耳科医生和放射科医生对耳区EAC变化的认识,并有助于住院医师接受培训。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
0.00%
发文量
84
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信