Performance of a seismically isolated building in Albania during the Durrës sequence of 2019 and a feasibility study of pendulum isolators in the region

Nikolin Hima, Ergys Çaushi, Luan Murtaj, Maria Gabriella Castellano
{"title":"Performance of a seismically isolated building in Albania during the Durrës sequence of 2019 and a feasibility study of pendulum isolators in the region","authors":"Nikolin Hima,&nbsp;Ergys Çaushi,&nbsp;Luan Murtaj,&nbsp;Maria Gabriella Castellano","doi":"10.1007/s44150-022-00076-3","DOIUrl":null,"url":null,"abstract":"<div><p>This work evaluates the behaviour of the only seismically isolated building in Albania during the Durrës sequence of 2019 and analyses the efficiency and feasibility of pendulum isolators in the region. The behaviour of the existing building is analysed through observational data gathered during on-site inspection and is verified through numerical simulations using the impact of the main shock of 26<sup><i>t</i><i>h</i></sup> of November 2019. The technical efficiency and the economic feasibility of seismic isolation through pendulum isolators for non-strategic buildings are analysed by designing, detailing, and estimating the cost of an ordinary six story residential building in both approaches (capacity design and seismic isolation approach), accounting for the local factors such as typical architecture, soil characterization, the level of the seismic hazard and the cost of the construction materials and workmanship in the densely populated region of central Albania. The structural behaviour assessment highlighted the superiority of the seismic isolation, and the feasibility analysis revealed that the initial cost for delivering seismically isolated buildings is higher than that of the conventional approach by some percentage. However, the gains in structural performance and the relatively high seismic hazard of the country make seismic isolation of buildings a relevant alternative in achieving seismic protection for buildings in the region.</p></div>","PeriodicalId":100117,"journal":{"name":"Architecture, Structures and Construction","volume":"3 1","pages":"65 - 85"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s44150-022-00076-3.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Architecture, Structures and Construction","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1007/s44150-022-00076-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This work evaluates the behaviour of the only seismically isolated building in Albania during the Durrës sequence of 2019 and analyses the efficiency and feasibility of pendulum isolators in the region. The behaviour of the existing building is analysed through observational data gathered during on-site inspection and is verified through numerical simulations using the impact of the main shock of 26th of November 2019. The technical efficiency and the economic feasibility of seismic isolation through pendulum isolators for non-strategic buildings are analysed by designing, detailing, and estimating the cost of an ordinary six story residential building in both approaches (capacity design and seismic isolation approach), accounting for the local factors such as typical architecture, soil characterization, the level of the seismic hazard and the cost of the construction materials and workmanship in the densely populated region of central Albania. The structural behaviour assessment highlighted the superiority of the seismic isolation, and the feasibility analysis revealed that the initial cost for delivering seismically isolated buildings is higher than that of the conventional approach by some percentage. However, the gains in structural performance and the relatively high seismic hazard of the country make seismic isolation of buildings a relevant alternative in achieving seismic protection for buildings in the region.

2019年Durrës序列期间阿尔巴尼亚地震隔离建筑的性能以及该地区钟摆隔离器的可行性研究
这项工作评估了2019年杜尔埃序列期间阿尔巴尼亚唯一一座隔震建筑的性能,并分析了该地区单摆隔震器的效率和可行性。通过现场检查期间收集的观测数据分析了现有建筑的性能,并通过2019年11月26日主震的影响进行了数值模拟验证。通过设计、详细说明和估计两种方法(容量设计和隔震方法)中普通六层住宅楼的成本,分析了非战略建筑通过摆式隔震器进行隔震的技术效率和经济可行性,并考虑了当地因素,如典型建筑、土壤特征、,阿尔巴尼亚中部人口稠密地区的地震危险程度以及建筑材料和工艺成本。结构性能评估强调了隔震的优越性,可行性分析表明,交付隔震建筑的初始成本比传统方法高出一定比例。然而,该国结构性能的提高和相对较高的地震危险性使建筑物的隔震成为该地区建筑物实现抗震保护的相关替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信