Physico-chemical quality of ashes post-incineration and waste from laboratory automaton biochemistry, hematology and serology in Togo

Q1 Social Sciences
Sadikou Agbere , Mabozou Kpemissi , Mamatchi Melila , Kamilou Ouro-Sama , Ameyo Dorkenoo , Gnon Tanouayi , Hodabalo Dheoulaba Solitoke , Koudjo Adje , Kissao Gnandi
{"title":"Physico-chemical quality of ashes post-incineration and waste from laboratory automaton biochemistry, hematology and serology in Togo","authors":"Sadikou Agbere ,&nbsp;Mabozou Kpemissi ,&nbsp;Mamatchi Melila ,&nbsp;Kamilou Ouro-Sama ,&nbsp;Ameyo Dorkenoo ,&nbsp;Gnon Tanouayi ,&nbsp;Hodabalo Dheoulaba Solitoke ,&nbsp;Koudjo Adje ,&nbsp;Kissao Gnandi","doi":"10.1016/j.jobb.2023.07.002","DOIUrl":null,"url":null,"abstract":"<div><p>Biochemistry, hematology and serology laboratories produce very heterogeneous discharges capable of polluting water, soil and the environment. The aim of this study is to evaluate the physico-chemical quality of the ashes, effluents and the range of equipment that produce the much effluent and pollutions.</p><p>This is a descriptive and cross-sectional study of 82 laboratories followed by the sampling of effluents from automatons. The physico-chemical parameters and trace elements are determined according to French Standardization Association (AFNOR) standards and used atomic absorption spectrometers and molecular absorption spectrometers. The Mindray hematology automaton is used for 64.7% and 81.5% of the cans are used to collect waste. Semehow 77.8% of discharges are released into sinks without adequate treatment in 42.6% of cases. Chemical analyses show that trace elements (TE) levels in effluents range from 5.89 ± 0.21 to 105.80 ± 0.96 μg/L for Arsenic; from 5.62 ± 0.34 to 6.53 ± 0.49 μg/L for Cadmium; 0.70 ± 0.01 to 10.63 ± 1.17 μg/L for Mercure and 35.72 ± 1.88 to 61.98 ± 5.15 μg/L for Plomb. pH ranges from 7.17 ± 0.65 to 8.3 ± 1.35 with total dissolved salts (TDS) range from 3260.20 ± 401.68 to 17117.41 ± 265.37 mg/L. All averages of contamination indices (CI) and polymetallic contamination indices (PCI) for post-incineration ashes are greater than 1.5 with the exception of Hg (0.22). For effluents, in addition to polymetallic contamination indices (PCI), CI in hematology effluents (1.09), all CI are less than 1. Hematology effluents have a lower pH and are much more mineralized and concentrated in trace elements while those from biochemistry and serology appear to be similar. However, the effluents of Biochemistry and Serology are more basic and concentrated in Suspended Solids with higher values obtained in Biochemistry. Although the physico-chemical parameters comply with WHO standards, discharges from automatons deserve appropriate treatment before their disposal.</p></div>","PeriodicalId":52875,"journal":{"name":"Journal of Biosafety and Biosecurity","volume":"5 3","pages":"Pages 107-115"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biosafety and Biosecurity","FirstCategoryId":"1093","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2588933823000341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Social Sciences","Score":null,"Total":0}
引用次数: 0

Abstract

Biochemistry, hematology and serology laboratories produce very heterogeneous discharges capable of polluting water, soil and the environment. The aim of this study is to evaluate the physico-chemical quality of the ashes, effluents and the range of equipment that produce the much effluent and pollutions.

This is a descriptive and cross-sectional study of 82 laboratories followed by the sampling of effluents from automatons. The physico-chemical parameters and trace elements are determined according to French Standardization Association (AFNOR) standards and used atomic absorption spectrometers and molecular absorption spectrometers. The Mindray hematology automaton is used for 64.7% and 81.5% of the cans are used to collect waste. Semehow 77.8% of discharges are released into sinks without adequate treatment in 42.6% of cases. Chemical analyses show that trace elements (TE) levels in effluents range from 5.89 ± 0.21 to 105.80 ± 0.96 μg/L for Arsenic; from 5.62 ± 0.34 to 6.53 ± 0.49 μg/L for Cadmium; 0.70 ± 0.01 to 10.63 ± 1.17 μg/L for Mercure and 35.72 ± 1.88 to 61.98 ± 5.15 μg/L for Plomb. pH ranges from 7.17 ± 0.65 to 8.3 ± 1.35 with total dissolved salts (TDS) range from 3260.20 ± 401.68 to 17117.41 ± 265.37 mg/L. All averages of contamination indices (CI) and polymetallic contamination indices (PCI) for post-incineration ashes are greater than 1.5 with the exception of Hg (0.22). For effluents, in addition to polymetallic contamination indices (PCI), CI in hematology effluents (1.09), all CI are less than 1. Hematology effluents have a lower pH and are much more mineralized and concentrated in trace elements while those from biochemistry and serology appear to be similar. However, the effluents of Biochemistry and Serology are more basic and concentrated in Suspended Solids with higher values obtained in Biochemistry. Although the physico-chemical parameters comply with WHO standards, discharges from automatons deserve appropriate treatment before their disposal.

多哥实验室自动机生化、血液学和血清学焚烧后灰烬和废物的理化性质
生物化学、血液学和血清学实验室产生的各种各样的排放物能够污染水、土壤和环境。本研究的目的是评估灰、废水和产生大量废水和污染的设备的物理化学质量。这是一项描述性和横断面研究,对82个实验室进行了描述性和横断面研究,随后对来自自动机的废水进行了采样。理化参数和微量元素的测定依据法国标准化协会(AFNOR)标准,采用原子吸收光谱仪和分子吸收光谱仪。迈瑞血液学自动机用于64.7%,81.5%的易拉罐用于收集废物。因此,在42.6%的病例中,77.8%的排放未经适当处理就排入了水槽。化学分析表明,出水中微量元素(TE)含量为5.89 ± 0.21 ~ 105.80 ± 0.96 μg/L;镉含量范围为5.62 ± 0.34 ~ 6.53 ± 0.49 ; 0.70±0.01  10.63±1.17  μg / L的水银和35.72 ± 1.88到61.98 ±5.15  Plombμg / L。pH值范围从7.17 ± 0.65到8.3 ±1.35 总溶解盐(TDS)范围从3260.20 ± 401.68到17117.41 ±  265.37 mg / L。焚烧后灰的污染指数(CI)和多金属污染指数(PCI)的平均值均大于1.5,除Hg(0.22)外。对于废水,除多金属污染指标(PCI)外,血液学废水CI(1.09)均小于1。血液学出水pH值较低,矿化程度高,微量元素含量高,而生物化学和血清学出水则类似。而生物化学和血清学的出水碱性较强,且以悬浮物为主,生物化学的测定值较高。虽然理化参数符合世卫组织标准,但自动机排放的排放物在处置前应得到适当处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Biosafety and Biosecurity
Journal of Biosafety and Biosecurity Social Sciences-Linguistics and Language
CiteScore
6.00
自引率
0.00%
发文量
20
审稿时长
41 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信