Jens van der Hulst, Héctor Martínez-Pérez-Cejuela, José Manuel Herrero-Martínez, Sergio Armenta
{"title":"Metal organic frameworks as advanced materials for the paper-based extraction of synthetic cannabinoids in oral fluids","authors":"Jens van der Hulst, Héctor Martínez-Pérez-Cejuela, José Manuel Herrero-Martínez, Sergio Armenta","doi":"10.1016/j.sampre.2023.100077","DOIUrl":null,"url":null,"abstract":"<div><p>In this manuscript, a paper-based device modified with metal-organic frameworks was applied for the extraction of synthetic cannabinoid receptor agonists (SCRAs) in oral fluids, taking profit of the several interaction mechanisms between MOF-analytes, followed by their quantification by LC-fluorescence detection. The resulting composite, named as NH<sub>2</sub>-UiO-66@paper, was characterized by different techniques such as infrared, scanning electron microscopy, among others. The extraction procedure was optimized by using a full factorial design after an appropriate selection of the significant variables. Once the method was optimized, the analytical parameters were studied including liner range (LOQ-400 µg L<sup>−1</sup>), limit of detection (0.7 to 2.8 µg L<sup>−1</sup>) and intra- and inter-batch precision (<8 and <20%, expressed as RSD, respectively). Next, the accuracy of the method was assessed at three different concentration levels (25, 75 and 100 µg L<sup>−1</sup>), obtaining values comprised from 64 to 98%. Finally, the method was applied for the analysis of oral fluids (n=25) (15 positives and 10 negative samples) and sensitivity, specificity and accuracy (efficiency) of the methodology were calculated obtaining 80, 100 and 88%, respectively.</p></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"7 ","pages":"Article 100077"},"PeriodicalIF":5.2000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S277258202300027X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1
Abstract
In this manuscript, a paper-based device modified with metal-organic frameworks was applied for the extraction of synthetic cannabinoid receptor agonists (SCRAs) in oral fluids, taking profit of the several interaction mechanisms between MOF-analytes, followed by their quantification by LC-fluorescence detection. The resulting composite, named as NH2-UiO-66@paper, was characterized by different techniques such as infrared, scanning electron microscopy, among others. The extraction procedure was optimized by using a full factorial design after an appropriate selection of the significant variables. Once the method was optimized, the analytical parameters were studied including liner range (LOQ-400 µg L−1), limit of detection (0.7 to 2.8 µg L−1) and intra- and inter-batch precision (<8 and <20%, expressed as RSD, respectively). Next, the accuracy of the method was assessed at three different concentration levels (25, 75 and 100 µg L−1), obtaining values comprised from 64 to 98%. Finally, the method was applied for the analysis of oral fluids (n=25) (15 positives and 10 negative samples) and sensitivity, specificity and accuracy (efficiency) of the methodology were calculated obtaining 80, 100 and 88%, respectively.