Freehand vs. depth-gauge rotary instruments for veneer preparation: A controlled randomized simulator study.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2024-07-08 Epub Date: 2023-10-17 DOI:10.2186/jpr.JPR_D_22_00317
M Oliver Ahlers, Georg Cachovan, Holger A Jakstat, Daniel Edelhoff, Jakob C Roehl, Ursula Platzer
{"title":"Freehand vs. depth-gauge rotary instruments for veneer preparation: A controlled randomized simulator study.","authors":"M Oliver Ahlers, Georg Cachovan, Holger A Jakstat, Daniel Edelhoff, Jakob C Roehl, Ursula Platzer","doi":"10.2186/jpr.JPR_D_22_00317","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether depth-gauge burs in veneer preparations influence preparation depth in a randomized, controlled, single-blinded trial and whether inexperienced operators can perform adequate veneer preparations.</p><p><strong>Methods: </strong>Participants were 20 undergraduate dental students with no prior veneer preparation experience. The instruments used were the \"Laminate Veneer System\" (LVS), \"Keramik-Veneers. de\" (KVD), and a \"Freehand\" group (FH) for reference. All participants prepared three educational acrylic resin maxillae and three mandibular central incisors mounted in typodonts in patient simulators. The objectives were to achieve a preparation depth of 0.6 mm (tooth 11) and 0.4 mm (tooth 31). The sequences of the instruments used and prepared teeth were randomized. The measurements were performed using a laser triangulation coordinate-measuring machine. The data were stratified according to tooth location.</p><p><strong>Results: </strong>The preparation depths of both depth-gauge-instrument-groups LVS and KVD achieved the objectives significantly better than did the instruments from the \"Freehand\" group (P < 0.001). The differences between the depth gauge groups were insignificant, although the maximum preparation depths were smaller in the KVD group. Regarding the prepared teeth, the preparation depths in the mandibular incisors were lower, and the differences were smaller.</p><p><strong>Conclusions: </strong>The use of special depth-gauge burs for initial veneer preparation leads to significantly lower preparation depths than \"Freehand\" preparations. The tapered instruments resulted in a lower incidence of extreme preparation depths. The inexperienced operators performed veneer preparation remarkably well.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_22_00317","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate whether depth-gauge burs in veneer preparations influence preparation depth in a randomized, controlled, single-blinded trial and whether inexperienced operators can perform adequate veneer preparations.

Methods: Participants were 20 undergraduate dental students with no prior veneer preparation experience. The instruments used were the "Laminate Veneer System" (LVS), "Keramik-Veneers. de" (KVD), and a "Freehand" group (FH) for reference. All participants prepared three educational acrylic resin maxillae and three mandibular central incisors mounted in typodonts in patient simulators. The objectives were to achieve a preparation depth of 0.6 mm (tooth 11) and 0.4 mm (tooth 31). The sequences of the instruments used and prepared teeth were randomized. The measurements were performed using a laser triangulation coordinate-measuring machine. The data were stratified according to tooth location.

Results: The preparation depths of both depth-gauge-instrument-groups LVS and KVD achieved the objectives significantly better than did the instruments from the "Freehand" group (P < 0.001). The differences between the depth gauge groups were insignificant, although the maximum preparation depths were smaller in the KVD group. Regarding the prepared teeth, the preparation depths in the mandibular incisors were lower, and the differences were smaller.

Conclusions: The use of special depth-gauge burs for initial veneer preparation leads to significantly lower preparation depths than "Freehand" preparations. The tapered instruments resulted in a lower incidence of extreme preparation depths. The inexperienced operators performed veneer preparation remarkably well.

单板制备用徒手与深度计旋转仪器:一项随机对照模拟研究。
目的:在一项随机、对照、单盲试验中,研究贴面制剂中的深度计囊状物是否会影响制剂深度,以及缺乏经验的操作人员是否能够进行足够的贴面制剂。方法:参与者为20名牙科本科生,此前没有贴面制备经验。使用的仪器是“层压单板系统”(LVS)、“Keramik Venees.de”(KVD)和“Freehand”组(FH),以供参考。所有参与者都准备了三个带有教育意义的丙烯酸树脂上颌和三个安装在患者模拟器中的下颌中切牙。目标是实现0.6毫米(齿11)和0.4毫米(齿31)的制备深度。使用的器械和准备好的牙齿的顺序是随机的。使用激光三角坐标测量机进行测量。根据牙齿位置对数据进行分层。结果:LVS和KVD两个深度计组的准备深度均明显优于“徒手”组(P<0.001)。尽管KVD组的最大准备深度较小,但深度计组之间的差异不显著。就预备牙而言,下颌切牙的预备深度较低,差异较小。结论:与“徒手”制剂相比,使用特殊的深度测量器进行单板初始制备可显著降低制备深度。锥形仪器降低了极端准备深度的发生率。经验不足的操作人员进行了非常好的贴面处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信