Corey A Smith, Vanessa L Josey, Michael E West, Oksana M Dyachok, Glen P Sharpe, Jayme R Vianna, Paul E Rafuse, Lesya M Shuba, Marcelo T Nicolela, Balwantray C Chauhan
{"title":"Variability of scan quality and perfusion density in longitudinal optical coherence tomography angiography imaging.","authors":"Corey A Smith, Vanessa L Josey, Michael E West, Oksana M Dyachok, Glen P Sharpe, Jayme R Vianna, Paul E Rafuse, Lesya M Shuba, Marcelo T Nicolela, Balwantray C Chauhan","doi":"10.1136/bjo-2022-322979","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>Optical coherence tomography angiography (OCT-A) images are subject to variability, but the extent to which learning impacts OCT-A measurements is unknown. We determined whether there is a learning effect in glaucoma patients and healthy controls imaged with OCT-A.</p><p><strong>Methods: </strong>Ninety-one open-angle glaucoma patients and 54 healthy controls were imaged every 4 months over a period of approximately 1 year in this longitudinal cohort study. We analysed 15°×15° scans, centred on the fovea, in one eye of each participant. Two-dimensional projection images for the superficial, intermediate and deep vascular plexuses were exported and binarised after which perfusion density was calculated. Linear mixed-effects models were used to investigate the association between perfusion density and follow-up time.</p><p><strong>Results: </strong>The mean (SD) age of glaucoma patients and healthy controls was 67.3 (8.1) years and 62.1 (9.0) years, respectively. There was a significant correlation between perfusion density and scan quality in both glaucoma patients (r=0.50 (95% CI 0.42 to 0.58); p<0.05) and healthy controls (r=0.41 (95% CI 0.29 to 0.52); p<0.05). An increase in perfusion density occurred over time and persisted, even after adjustment for scan quality (1.75% per year (95% CI 1.14 to 2.37), p<0.01).</p><p><strong>Conclusions: </strong>Perfusion density measurements are subject to increasing experience of either the operator or participant, or a combination of both. These findings have implications for the interpretation of longitudinal measurements with OCT-A.</p>","PeriodicalId":9313,"journal":{"name":"British Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":3.7000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bjo-2022-322979","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background/aims: Optical coherence tomography angiography (OCT-A) images are subject to variability, but the extent to which learning impacts OCT-A measurements is unknown. We determined whether there is a learning effect in glaucoma patients and healthy controls imaged with OCT-A.
Methods: Ninety-one open-angle glaucoma patients and 54 healthy controls were imaged every 4 months over a period of approximately 1 year in this longitudinal cohort study. We analysed 15°×15° scans, centred on the fovea, in one eye of each participant. Two-dimensional projection images for the superficial, intermediate and deep vascular plexuses were exported and binarised after which perfusion density was calculated. Linear mixed-effects models were used to investigate the association between perfusion density and follow-up time.
Results: The mean (SD) age of glaucoma patients and healthy controls was 67.3 (8.1) years and 62.1 (9.0) years, respectively. There was a significant correlation between perfusion density and scan quality in both glaucoma patients (r=0.50 (95% CI 0.42 to 0.58); p<0.05) and healthy controls (r=0.41 (95% CI 0.29 to 0.52); p<0.05). An increase in perfusion density occurred over time and persisted, even after adjustment for scan quality (1.75% per year (95% CI 1.14 to 2.37), p<0.01).
Conclusions: Perfusion density measurements are subject to increasing experience of either the operator or participant, or a combination of both. These findings have implications for the interpretation of longitudinal measurements with OCT-A.
期刊介绍:
The British Journal of Ophthalmology (BJO) is an international peer-reviewed journal for ophthalmologists and visual science specialists. BJO publishes clinical investigations, clinical observations, and clinically relevant laboratory investigations related to ophthalmology. It also provides major reviews and also publishes manuscripts covering regional issues in a global context.