{"title":"Loop Anchor Tension Band Fixation for Olecranon Fractures and Chevron Olecranon Osteotomy.","authors":"W. Ho, Shu-Hsin Yao, Chun-Ho Chen","doi":"10.1097/BTH.0000000000000394","DOIUrl":null,"url":null,"abstract":"Although tension band wiring is effective for treating olecranon fractures, it is associated with a high reoperation rate because of hardware-related problems. The loop anchor tension band technique is a novel modification of the Arbeitsgemeinschaft für Osteosynthesefragen (AO)-modified tension band wiring technique. This technique is suitable for treating olecranon fractures without severe comminution and olecranon osteotomy. In the current case series, 2 intramedullary 1.25-mm Kirschner wires (K wires) were inserted as temporary fixation into the ulnar shaft from the olecranon after anatomical reduction. The proximal end of each K-wire was bent into a loop shape and advanced deep into the triceps tendon. A transverse hole was drilled distal to the fracture site, and a 1.0-mm metal wire was passed through the bone tunnel and the loops. The wire was tightened to form a figure-of-eight tension band construct. In total, 10 patients with a mean age of 49 (range: 19 to 85) years were included in this pilot series. The mean and minimum follow-up periods were 13.9 and 12 months, respectively. All fractures achieved favorable union, both radiographically and clinically. The mean QuickDASH score was 15.4 (range: 13.6 to 18.2) and the mean Mayo elbow performance score was 94 (range: 85 to 100). None of the patients experienced K-wire migration. The loop anchor tension band technique is a simple, cost effective modification of conventional tension band wiring and exhibited no implant migration in a pilot series.","PeriodicalId":39303,"journal":{"name":"Techniques in Hand and Upper Extremity Surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Hand and Upper Extremity Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTH.0000000000000394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Although tension band wiring is effective for treating olecranon fractures, it is associated with a high reoperation rate because of hardware-related problems. The loop anchor tension band technique is a novel modification of the Arbeitsgemeinschaft für Osteosynthesefragen (AO)-modified tension band wiring technique. This technique is suitable for treating olecranon fractures without severe comminution and olecranon osteotomy. In the current case series, 2 intramedullary 1.25-mm Kirschner wires (K wires) were inserted as temporary fixation into the ulnar shaft from the olecranon after anatomical reduction. The proximal end of each K-wire was bent into a loop shape and advanced deep into the triceps tendon. A transverse hole was drilled distal to the fracture site, and a 1.0-mm metal wire was passed through the bone tunnel and the loops. The wire was tightened to form a figure-of-eight tension band construct. In total, 10 patients with a mean age of 49 (range: 19 to 85) years were included in this pilot series. The mean and minimum follow-up periods were 13.9 and 12 months, respectively. All fractures achieved favorable union, both radiographically and clinically. The mean QuickDASH score was 15.4 (range: 13.6 to 18.2) and the mean Mayo elbow performance score was 94 (range: 85 to 100). None of the patients experienced K-wire migration. The loop anchor tension band technique is a simple, cost effective modification of conventional tension band wiring and exhibited no implant migration in a pilot series.
环锚张力带内固定治疗鹰嘴骨折和Chevron鹰嘴截骨术。
尽管张力带布线治疗鹰嘴骨折是有效的,但由于硬件相关问题,它的再手术率很高。环形锚张力带技术是对Arbeitsgemeinschaft für Osteossynthesefragen(AO)改良张力带布线技术的一种新改进。该技术适用于鹰嘴骨折的治疗,无严重粉碎和鹰嘴截骨。在目前的病例系列中,解剖复位后,将2根1.25mm的克氏针(K线)作为临时固定件从尺骨鹰嘴插入尺骨干。每根K线的近端弯曲成环状,并深入三头肌肌腱。在骨折部位远端钻一个横向孔,并将一根1.0毫米的金属丝穿过骨隧道和环。将金属丝拉紧,形成一个8字形的张力带结构。总共有10名平均年龄49岁(范围:19至85岁)的患者被纳入该试点系列。平均随访时间为13.9个月,最短随访时间为12个月。所有骨折在放射学和临床上都获得了良好的愈合。QuickDASH的平均得分为15.4(范围:13.6至18.2),Mayo肘部的平均表现得分为94(范围:85至100)。所有患者均未出现K线迁移。环锚张力带技术是对传统张力带布线的一种简单、经济高效的改进,在试点系列中没有表现出植入物迁移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
54
期刊介绍: Techniques in Hand & Upper Extremity Surgery presents authoritative, practical information on today"s advances in hand and upper extremity surgery. It features articles by leading experts on the latest surgical techniques, the newest equipment, and progress in therapies for rehabilitation. The primary focus of the journal is hand surgery, but articles on the wrist, elbow, and shoulder are also included. Major areas covered include arthroscopy, microvascular surgery, plastic surgery, congenital anomalies, tendon and nerve disorders, trauma, and work-related injuries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信