COMPARATIVE EVALUATION OF THE EFFECT OF DIFFERENT ROTARY INSTRUMENT SYSTEMS ON THE AMOUNT OF APICALLY EXTRUDED DEBRIS

Q3 Dentistry
R. Zan, Bilge Lenger
{"title":"COMPARATIVE EVALUATION OF THE EFFECT OF DIFFERENT ROTARY INSTRUMENT SYSTEMS ON THE AMOUNT OF APICALLY EXTRUDED DEBRIS","authors":"R. Zan, Bilge Lenger","doi":"10.7126/cumudj.1128769","DOIUrl":null,"url":null,"abstract":"Objectives: The purpose of our study is to examine in vitro the amount of debris extrusion from the apical after root canal preparation with different rotary instruments. \nMaterials and Methods: In present study, 60 single root single-canal lower premolar human teeth were used. The teeth were randomly selected and divided into 4 main groups (n=15). Root canals are shaped by using 2Shape, One Curve and XP-3DEndo Shaper working in rotational motion and WaveOne Gold working reciprocal motion. Later, the weight of each eppendorf tube was weighed on a precision scale and the amount of debris extrusion from the apical was determined with 10ˉ4 precision by subtracting the empty weight of the tube. Since the parametric test assumptions were fulfilled in the evaluation of the data obtained regarding the amount of debris extrusion from the apical of file systems by loading them into the SPSS 22.0 program, One-Way Variance analysis was used and the level of error was taken as 0.05. \nResults: When the amount of debris extrusion from the apical is ordered from high to low, it was seen that there are 2Shape, One Curve, XP-Endo Shaper, WaveOne Gold. However, the difference between study groups was not statistically significant (p> 0.05). \nConclusions: Considering the results obtained in terms of debris extrusion from the apical about the new generation files with different metallurgy, kinematics, structural features, designs and different configurations that we used ın present study, it was seen that these systems would not show any difference in terms of the effect of debris on the success of endodontic treatment.","PeriodicalId":10781,"journal":{"name":"Cumhuriyet Dental Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cumhuriyet Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7126/cumudj.1128769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 1

Abstract

Objectives: The purpose of our study is to examine in vitro the amount of debris extrusion from the apical after root canal preparation with different rotary instruments. Materials and Methods: In present study, 60 single root single-canal lower premolar human teeth were used. The teeth were randomly selected and divided into 4 main groups (n=15). Root canals are shaped by using 2Shape, One Curve and XP-3DEndo Shaper working in rotational motion and WaveOne Gold working reciprocal motion. Later, the weight of each eppendorf tube was weighed on a precision scale and the amount of debris extrusion from the apical was determined with 10ˉ4 precision by subtracting the empty weight of the tube. Since the parametric test assumptions were fulfilled in the evaluation of the data obtained regarding the amount of debris extrusion from the apical of file systems by loading them into the SPSS 22.0 program, One-Way Variance analysis was used and the level of error was taken as 0.05. Results: When the amount of debris extrusion from the apical is ordered from high to low, it was seen that there are 2Shape, One Curve, XP-Endo Shaper, WaveOne Gold. However, the difference between study groups was not statistically significant (p> 0.05). Conclusions: Considering the results obtained in terms of debris extrusion from the apical about the new generation files with different metallurgy, kinematics, structural features, designs and different configurations that we used ın present study, it was seen that these systems would not show any difference in terms of the effect of debris on the success of endodontic treatment.
不同旋转仪器系统对顶部挤出碎屑量影响的比较评价
目的:我们研究的目的是在体外检测不同旋转器械预备根管后根尖碎片挤出的量。材料与方法:本研究选用60颗单根单管下前磨牙。随机选择牙齿并将其分为4个主要组(n=15)。根管成形采用2Shape、One Curve和XP-3DEndo Shaper进行旋转运动,WaveOne Gold进行往复运动。随后,在精密天平上称量每个埃彭多夫管的重量,并通过减去管的空重量以10-4的精度确定从根尖挤出的碎屑量。由于在评估从文件系统顶端挤出的碎片量的数据时,通过将其加载到SPSS 22.0程序中,满足了参数检验假设,因此使用了单向方差分析,误差水平取0.05。结果:当碎屑从根尖挤出的量从高到低依次为2Shape、One Curve、XP Endo Shaper、WaveOne Gold。然而,研究组之间的差异没有统计学意义(p>0.05)。结论:考虑到我们在本研究中使用的具有不同冶金、运动学、结构特征、设计和不同配置的新一代锉刀从根尖挤出碎屑的结果,可以看出,这些系统在碎片对牙髓治疗成功的影响方面不会显示出任何差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cumhuriyet Dental Journal
Cumhuriyet Dental Journal Dentistry-Dentistry (all)
CiteScore
0.40
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信