{"title":"Mountain gazelle optimisation-based 3DOF-FOPID-virtual inertia controller for frequency control of low inertia microgrid","authors":"Swapan Santra, Mala De","doi":"10.1049/esi2.12111","DOIUrl":null,"url":null,"abstract":"<p>The primary objective of the authors is to design a new robust and improved virtual inertia controller (VIC) for renewable energy dominated inverter interfaced low inertia microgrid (LIMG). Increasing penetration of inertia-less renewable generation in microgrid leads to increased frequency deviation during and after a disturbance. To improve the frequency response of the LIMG, conventional VIC added with different second stage and third stage controllers are proposed in existing works. Higher degree-of-freedom (DOF) PID controller synchronised with fractional-order (FO) operators are used with conventional VIC controllers. These controllers work in addition with conventional VIC and the multi-stage controllers make the system more complex. To reduce the number of controller stages and, subsequently, reduce cost and complexity of the system, a single stage 3DOF-FOPID controller is proposed to mitigate the frequency deviation after a disturbance in a LIMG. Performance of the proposed single stage controller is compared with that of the existing controllers to establish the advantages of the proposed controller. The parameters of the proposed 3DOF-FOPID controller are optimised by Mountain Gazelle Optimsation. The robustness of this controller is also tested for random load fluctuation and renewable power variations in presence of system non-linearities.</p>","PeriodicalId":33288,"journal":{"name":"IET Energy Systems Integration","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/esi2.12111","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Energy Systems Integration","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/esi2.12111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
The primary objective of the authors is to design a new robust and improved virtual inertia controller (VIC) for renewable energy dominated inverter interfaced low inertia microgrid (LIMG). Increasing penetration of inertia-less renewable generation in microgrid leads to increased frequency deviation during and after a disturbance. To improve the frequency response of the LIMG, conventional VIC added with different second stage and third stage controllers are proposed in existing works. Higher degree-of-freedom (DOF) PID controller synchronised with fractional-order (FO) operators are used with conventional VIC controllers. These controllers work in addition with conventional VIC and the multi-stage controllers make the system more complex. To reduce the number of controller stages and, subsequently, reduce cost and complexity of the system, a single stage 3DOF-FOPID controller is proposed to mitigate the frequency deviation after a disturbance in a LIMG. Performance of the proposed single stage controller is compared with that of the existing controllers to establish the advantages of the proposed controller. The parameters of the proposed 3DOF-FOPID controller are optimised by Mountain Gazelle Optimsation. The robustness of this controller is also tested for random load fluctuation and renewable power variations in presence of system non-linearities.