{"title":"Construction of an Amperometric Lactate Biosensor Based onImmobilization of Lactate Dehydrogenase Nanoparticles onto PencilGraphite Electrode","authors":"Vinay Narwal, Kusum Dagar, C. Pundir","doi":"10.4172/2161-1009.1000331","DOIUrl":null,"url":null,"abstract":"Nanoparticles (NPs) of commercial lactate dehydrogenase from rabbit muscle were prepared, characterized and immobilized covalently onto pencil graphite (PG) electrode to fabricate an improved amperometric lactate biosensor (LDHNPs/PGE). The biosensor showed an optimum response within 2.5s at pH 7.0, temperature 35°C, at an applied potential of -0.4V. The wide linear response was produced by biosensor with in a concentration range of lactic acid (0.001 μM to 45 mM) and current (mA) under optimal conditions. The LDHNPs/PGE electrode showed high sensitivity (2.45 ± 2.0 μA cm−2 μM−1); a lower detection limit (0.001 μM) and good correlation coefficient (R2 = 0.99) with a standard enzymic colorimetric method. The evaluation study of biosensor offered a good analytical recovery of 98.01%, when lactic acid concentration was added in the sera sample. In addition, within and between batches coefficients of variation for working electrode were detected as 0.03% and 0.04%, respectively. The biosensor was applied for the detection of lactic acid in the serum of apparently healthy subject and patients affected from cardiogenic shocks. There was a 10% loss in initial activity of biosensor after its regular use over a time period of 180 days, while being stored at 4°C.","PeriodicalId":89896,"journal":{"name":"Biochemistry and analytical biochemistry : current research","volume":" ","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4172/2161-1009.1000331","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemistry and analytical biochemistry : current research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2161-1009.1000331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
Nanoparticles (NPs) of commercial lactate dehydrogenase from rabbit muscle were prepared, characterized and immobilized covalently onto pencil graphite (PG) electrode to fabricate an improved amperometric lactate biosensor (LDHNPs/PGE). The biosensor showed an optimum response within 2.5s at pH 7.0, temperature 35°C, at an applied potential of -0.4V. The wide linear response was produced by biosensor with in a concentration range of lactic acid (0.001 μM to 45 mM) and current (mA) under optimal conditions. The LDHNPs/PGE electrode showed high sensitivity (2.45 ± 2.0 μA cm−2 μM−1); a lower detection limit (0.001 μM) and good correlation coefficient (R2 = 0.99) with a standard enzymic colorimetric method. The evaluation study of biosensor offered a good analytical recovery of 98.01%, when lactic acid concentration was added in the sera sample. In addition, within and between batches coefficients of variation for working electrode were detected as 0.03% and 0.04%, respectively. The biosensor was applied for the detection of lactic acid in the serum of apparently healthy subject and patients affected from cardiogenic shocks. There was a 10% loss in initial activity of biosensor after its regular use over a time period of 180 days, while being stored at 4°C.