Construction of an Amperometric Lactate Biosensor Based onImmobilization of Lactate Dehydrogenase Nanoparticles onto PencilGraphite Electrode

Vinay Narwal, Kusum Dagar, C. Pundir
{"title":"Construction of an Amperometric Lactate Biosensor Based onImmobilization of Lactate Dehydrogenase Nanoparticles onto PencilGraphite Electrode","authors":"Vinay Narwal, Kusum Dagar, C. Pundir","doi":"10.4172/2161-1009.1000331","DOIUrl":null,"url":null,"abstract":"Nanoparticles (NPs) of commercial lactate dehydrogenase from rabbit muscle were prepared, characterized and immobilized covalently onto pencil graphite (PG) electrode to fabricate an improved amperometric lactate biosensor (LDHNPs/PGE). The biosensor showed an optimum response within 2.5s at pH 7.0, temperature 35°C, at an applied potential of -0.4V. The wide linear response was produced by biosensor with in a concentration range of lactic acid (0.001 μM to 45 mM) and current (mA) under optimal conditions. The LDHNPs/PGE electrode showed high sensitivity (2.45 ± 2.0 μA cm−2 μM−1); a lower detection limit (0.001 μM) and good correlation coefficient (R2 = 0.99) with a standard enzymic colorimetric method. The evaluation study of biosensor offered a good analytical recovery of 98.01%, when lactic acid concentration was added in the sera sample. In addition, within and between batches coefficients of variation for working electrode were detected as 0.03% and 0.04%, respectively. The biosensor was applied for the detection of lactic acid in the serum of apparently healthy subject and patients affected from cardiogenic shocks. There was a 10% loss in initial activity of biosensor after its regular use over a time period of 180 days, while being stored at 4°C.","PeriodicalId":89896,"journal":{"name":"Biochemistry and analytical biochemistry : current research","volume":" ","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4172/2161-1009.1000331","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemistry and analytical biochemistry : current research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2161-1009.1000331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Nanoparticles (NPs) of commercial lactate dehydrogenase from rabbit muscle were prepared, characterized and immobilized covalently onto pencil graphite (PG) electrode to fabricate an improved amperometric lactate biosensor (LDHNPs/PGE). The biosensor showed an optimum response within 2.5s at pH 7.0, temperature 35°C, at an applied potential of -0.4V. The wide linear response was produced by biosensor with in a concentration range of lactic acid (0.001 μM to 45 mM) and current (mA) under optimal conditions. The LDHNPs/PGE electrode showed high sensitivity (2.45 ± 2.0 μA cm−2 μM−1); a lower detection limit (0.001 μM) and good correlation coefficient (R2 = 0.99) with a standard enzymic colorimetric method. The evaluation study of biosensor offered a good analytical recovery of 98.01%, when lactic acid concentration was added in the sera sample. In addition, within and between batches coefficients of variation for working electrode were detected as 0.03% and 0.04%, respectively. The biosensor was applied for the detection of lactic acid in the serum of apparently healthy subject and patients affected from cardiogenic shocks. There was a 10% loss in initial activity of biosensor after its regular use over a time period of 180 days, while being stored at 4°C.
基于乳酸脱氢酶纳米粒子在铅笔石墨电极上的固定化构建乳酸安培生物传感器
从兔肌肉中制备、表征并共价固定在笔形石墨(PG)电极上的市售乳酸脱氢酶纳米粒子(NP),制备了一种改进的电流型乳酸生物传感器(LDHNP/PGE)。该生物传感器在pH 7.0、温度35°C、外加电位-0.4V的条件下,在2.5s内显示出最佳响应。在最佳条件下,乳酸浓度(0.001μM至45mM)和电流(mA)范围内的生物传感器产生了宽的线性响应。LDHNP/PGE电极灵敏度高(2.45±2.0μA cm−2μM−1);μM)和良好的相关系数(R2=0.99)。当在血清样品中加入乳酸浓度时,生物传感器的评价研究提供了98.01%的良好分析回收率。此外,工作电极的批内和批间变异系数分别为0.03%和0.04%。该生物传感器用于检测明显健康的受试者和心源性休克患者血清中的乳酸。生物传感器在4°C下储存180天后,其初始活性损失了10%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书