Harmonic effects of sham acupuncture at Tsu San Li (St-36) in the radial pulse wave

IF 3.3 3区 医学 Q1 INTEGRATIVE & COMPLEMENTARY MEDICINE
Kuang-Chieh Hsueh , Jenq-Haur Wang , Chi-Ying Chen , Jin-Hua Chen , George Hsiao , Yu-Cheng Kuo
{"title":"Harmonic effects of sham acupuncture at Tsu San Li (St-36) in the radial pulse wave","authors":"Kuang-Chieh Hsueh ,&nbsp;Jenq-Haur Wang ,&nbsp;Chi-Ying Chen ,&nbsp;Jin-Hua Chen ,&nbsp;George Hsiao ,&nbsp;Yu-Cheng Kuo","doi":"10.1016/j.jtcme.2023.07.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and aim</h3><p>Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.</p></div><div><h3>Experimental procedure</h3><p>In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.</p></div><div><h3>Results</h3><p>Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.</p></div><div><h3>Conclusions</h3><p>This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.</p></div>","PeriodicalId":17449,"journal":{"name":"Journal of Traditional and Complementary Medicine","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Traditional and Complementary Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2225411023000780","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INTEGRATIVE & COMPLEMENTARY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aim

Acupuncture has been criticized as a theatrical placebo for the sham effect. Unfortunately, sham tests used in control groups in acupuncture studies have always ignored the underlying biophysical factors, including resonance involved in acupuncture points and meridians.

Experimental procedure

In this study, the effects of sham acupuncture at Tsu San Li (St-36) were examined by analyzing noninvasive 30-sec. recordings of the radial arterial pulses for 3 groups of patients treated with different probes (blunt, sharp, and patch) on the superficial skin of the acupuncture point. The 3 groups were then treated with the sharp probe for 3 different periods (16, 30, and 50 s). Then we compared the harmonics of the radial arterial pulse after Fourier transformation before and after the treatment.

Results

Our results indicated that different probes have effects similar to needle insertion at Tsu San Li. Meanwhile, the harmonic effect of the sharp probe strengthened as time increased.

Conclusions

This study revealed that the meridian effect of sham testing from mechanical stimulation, even from simple touch, on an acupuncture point, should not be overlooked. Thus, even simple touch can be added to electrical or laser acupuncture.

Abstract Image

假针刺足三里对桡动脉脉搏波的调和作用
背景和目的针刺因其虚假效果而被批评为戏剧安慰剂。不幸的是,在针灸研究中用于对照组的假试验总是忽略了潜在的生物物理因素,包括涉及穴位和经络的共振。实验方法本研究通过无创30秒分析,观察假针刺足三里(St-36)的作用。三组患者在穴位浅表皮肤上使用不同探针(钝、尖、贴)记录桡动脉脉搏。三组患者分别在治疗前、治疗后的16、30、50 s 3个不同时段进行尖探针治疗,比较治疗前后桡动脉脉冲傅立叶变换后的谐波。结果不同探针对足三里的刺入效果相似。同时,尖探针的谐波效应随着时间的增加而增强。结论本研究揭示了机械刺激(甚至是简单的触摸)对穴位的经络效应不应被忽视。因此,即使是简单的触摸也可以添加到电或激光针灸中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Traditional and Complementary Medicine
Journal of Traditional and Complementary Medicine Medicine-Complementary and Alternative Medicine
CiteScore
9.30
自引率
6.70%
发文量
78
审稿时长
66 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信