A Comparative Evaluation of Apically Extruded Debris using Three Rotary and One Reciprocating Instrumentation Ni‑Ti Systems: An in Vitro Study

Q3 Dentistry
Maha A. Habeeb
{"title":"A Comparative Evaluation of Apically Extruded Debris using Three Rotary and One Reciprocating Instrumentation Ni‑Ti Systems: An in Vitro Study","authors":"Maha A. Habeeb","doi":"10.4103/jofs.jofs_208_21","DOIUrl":null,"url":null,"abstract":"Introduction: Chemomechanical preparation of root aims to eliminate the inflamed and necrotic tissue with infected dentine. This process may produce some debris extruded apically. The aim of our study was to compare and to assess the amount debris extruded apically by using four different single files systems. Materials and methods: Forty mandibular premolars which were cut to the cementoenamel junction with a diamond disk to similar lengths. Glass vials were pre-weighed and used to collect debris. The samples were divided into four groups: Group A (HyFlex EDM), Group B (AF Blue S-One), Group C (WaveOne Gold) and Group D (XPS). We used distilled water for irrigation. All canals were prepared to the size #25, then the vials were placed in hot air oven at 180°C for 5 h for evaporation of debris. Then vials containing dry debris were weighed again. The final mass of the extruded debris was calculated by subtracting the weight of initial empty vial from vial containing dry debris. ANOVA and LSD tests were applied to analyse data. Results: According to the results obtained in this study, all the tested files caused extrusion of debris apically. A highly significant difference was observed between all groups (P < 0.01). The highest value for debris extrusion was observed in rotary HyFlex EDM (0.03693 gm), whereas reciprocating C group (WaveOne Gold) showed the lowest value (0.01938 gm). Conclusion: The continuous rotary files caused less debris when compared with reciprocating one. Also all systems caused some degree of apical extrusion.","PeriodicalId":16651,"journal":{"name":"Journal of Orofacial Sciences","volume":"14 1","pages":"93 - 99"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jofs.jofs_208_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Chemomechanical preparation of root aims to eliminate the inflamed and necrotic tissue with infected dentine. This process may produce some debris extruded apically. The aim of our study was to compare and to assess the amount debris extruded apically by using four different single files systems. Materials and methods: Forty mandibular premolars which were cut to the cementoenamel junction with a diamond disk to similar lengths. Glass vials were pre-weighed and used to collect debris. The samples were divided into four groups: Group A (HyFlex EDM), Group B (AF Blue S-One), Group C (WaveOne Gold) and Group D (XPS). We used distilled water for irrigation. All canals were prepared to the size #25, then the vials were placed in hot air oven at 180°C for 5 h for evaporation of debris. Then vials containing dry debris were weighed again. The final mass of the extruded debris was calculated by subtracting the weight of initial empty vial from vial containing dry debris. ANOVA and LSD tests were applied to analyse data. Results: According to the results obtained in this study, all the tested files caused extrusion of debris apically. A highly significant difference was observed between all groups (P < 0.01). The highest value for debris extrusion was observed in rotary HyFlex EDM (0.03693 gm), whereas reciprocating C group (WaveOne Gold) showed the lowest value (0.01938 gm). Conclusion: The continuous rotary files caused less debris when compared with reciprocating one. Also all systems caused some degree of apical extrusion.
使用三个旋转和一个往复仪器Ni - Ti系统对根尖挤压碎片的比较评价:一项体外研究
牙根化学机械制备的目的是消除感染牙本质的炎症和坏死组织。这个过程可能会产生一些根尖挤压的碎片。我们研究的目的是比较和评估使用四种不同的单文件系统顶端挤压碎片的数量。材料与方法:将40颗下颌前磨牙用金刚石盘切割至牙釉质粘接处。玻璃小瓶被预先称重,用来收集碎片。将样品分为四组:A组(HyFlex EDM)、B组(AF Blue S-One)、C组(WaveOne Gold)和D组(XPS)。我们用蒸馏水灌溉。所有管均准备为25号,然后将小瓶置于180°C的热空气烘箱中蒸发5小时,使碎片蒸发。然后对装有干碎片的小瓶再次称重。挤出碎片的最终质量通过从含有干碎片的小瓶中减去初始空瓶的重量来计算。采用方差分析和LSD检验对数据进行分析。结果:根据本研究结果,所有的试验锉都引起了根尖碎片的挤压。各组间差异极显著(P < 0.01)。旋转HyFlex EDM组的碎屑挤压量最高(0.03693 gm),而往复C组(WaveOne Gold)的碎屑挤压量最低(0.01938 gm)。结论:与往复式锉相比,连续式锉产生的碎屑较少。此外,所有系统都造成了一定程度的顶端挤压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orofacial Sciences
Journal of Orofacial Sciences Dentistry-Orthodontics
CiteScore
0.60
自引率
0.00%
发文量
13
审稿时长
31 weeks
期刊介绍: Journal of Orofacial Sciences is dedicated to noblest profession of Dentistry, and to the young & blossoming intellects of dentistry, with whom the future of dentistry will be cherished better. The prime aim of this journal is to advance the science and art of dentistry. This journal is an educational tool to encourage and share the acquired knowledge with our peers. It also to improves the standards and quality of therauptic methods. This journal assures you to gain knowledge in recent advances and research activities. The journal publishes original scientific papers with special emphasis on research, unusual case reports, editorial, review articles, book reviews & other relevant information in context of high professional standards.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信