Solvent effects on the graphite surface targeting the construction of voltammetric sensors with potential applications in pharmaceutical area

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Thainá M. Vilela, Mateus A. Gonçalves, Roberta C. Martins, Matheus J. F. Bazzana, Adelir A. Saczk, Teodorico C. Ramalho, Fabiana S. Felix
{"title":"Solvent effects on the graphite surface targeting the construction of voltammetric sensors with potential applications in pharmaceutical area","authors":"Thainá M. Vilela,&nbsp;Mateus A. Gonçalves,&nbsp;Roberta C. Martins,&nbsp;Matheus J. F. Bazzana,&nbsp;Adelir A. Saczk,&nbsp;Teodorico C. Ramalho,&nbsp;Fabiana S. Felix","doi":"10.1002/elan.202300075","DOIUrl":null,"url":null,"abstract":"<p>In this paper the effect of different solvents (ethanol, acetone, dichloromethane and hexane) in the surface treatment of graphite for the construction of voltammetric sensors was evaluated. During voltammetric experiments of the graphite powder-based sensor treated with ethanol, it was possible to observe a significant increase in current signals for the redox process of the model analyte (acetaminophen), as well as an increase in the area density of this sensor compared to its unmodified electrode. Theoretical studies involving Density Functional Theory (DFT) and Quantum Theory of Atoms in Molecules (QTAIM) showed greater interaction and stability when graphite was treated with ethanol solvent. Moreover, the theoretical calculations indicated that treating the voltammetric sensor with ethanol offers improvements in the electrochemical response of the model analyte mainly due to a higher spin density, and a partially covalent interaction between solvent and graphite surface. Therefore, graphite powder-based sensors treated with ethanol were used for determination of acetaminophen in pharmaceutical samples and their results were in good agreement with those obtained by using spectrophotometric method recommended by Pharmacopoeia.</p>","PeriodicalId":162,"journal":{"name":"Electroanalysis","volume":"35 11","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroanalysis","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/elan.202300075","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper the effect of different solvents (ethanol, acetone, dichloromethane and hexane) in the surface treatment of graphite for the construction of voltammetric sensors was evaluated. During voltammetric experiments of the graphite powder-based sensor treated with ethanol, it was possible to observe a significant increase in current signals for the redox process of the model analyte (acetaminophen), as well as an increase in the area density of this sensor compared to its unmodified electrode. Theoretical studies involving Density Functional Theory (DFT) and Quantum Theory of Atoms in Molecules (QTAIM) showed greater interaction and stability when graphite was treated with ethanol solvent. Moreover, the theoretical calculations indicated that treating the voltammetric sensor with ethanol offers improvements in the electrochemical response of the model analyte mainly due to a higher spin density, and a partially covalent interaction between solvent and graphite surface. Therefore, graphite powder-based sensors treated with ethanol were used for determination of acetaminophen in pharmaceutical samples and their results were in good agreement with those obtained by using spectrophotometric method recommended by Pharmacopoeia.

Abstract Image

溶剂对石墨表面的影响在制药领域具有潜在的应用前景
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Electroanalysis
Electroanalysis 化学-电化学
CiteScore
6.00
自引率
3.30%
发文量
222
审稿时长
2.4 months
期刊介绍: Electroanalysis is an international, peer-reviewed journal covering all branches of electroanalytical chemistry, including both fundamental and application papers as well as reviews dealing with new electrochemical sensors and biosensors, nanobioelectronics devices, analytical voltammetry, potentiometry, new electrochemical detection schemes based on novel nanomaterials, fuel cells and biofuel cells, and important practical applications. Serving as a vital communication link between the research labs and the field, Electroanalysis helps you to quickly adapt the latest innovations into practical clinical, environmental, food analysis, industrial and energy-related applications. Electroanalysis provides the most comprehensive coverage of the field and is the number one source for information on electroanalytical chemistry, electrochemical sensors and biosensors and fuel/biofuel cells.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信