The resistance of the intracanal retention thickness with flowable short fiber reinforced composite (SFRC) materials towards fracture toughness

Isabella Audy Tania, Wiena Widyastuti Fitria
{"title":"The resistance of the intracanal retention thickness with flowable short fiber reinforced composite (SFRC) materials towards fracture toughness","authors":"Isabella Audy Tania, Wiena Widyastuti Fitria","doi":"10.24198/pjd.vol35no1.45151","DOIUrl":null,"url":null,"abstract":"ABSTRACTIntroduction: Dental hard tissue problems were relatively high in Indonesia. If these problems were ignored, they would cause pulpal necrosis. The main treatment for this case was Root Canal Treatment (RCT). The selection of post-RCT treatment and suitable materials was important. One of the examples was short fiber reinforced composite (SFRC) which can be an option for intracanal retention treatment. This study aims to analyze the resistance of the intracanal retention thickness with flowable fiber reinforced composite materials toward fracture toughness. Methods: This research was using a correlative laboratory experimental method with a post-test group-only design. This study's samples were SFRC material inserted in 27 extracted mandibular first premolars with a length of 21 mm ± 2 mm and root canal walls width of 2 mm. All samples were given intracanal retention at a depth of 2 mm below the orifice and divided into 3 groups: intracanal retention with thickness of (A) 6 mm, (B) 5 mm, and (C) 4 mm. RCT was performed using the crown-down technique. The bonding agent was applied, and then light cured for 20 seconds. SFRC was applied according to the sample group and light cured for 20 seconds per 2 mm, followed by filling with composite resin. The sample was implanted in the dental stone 2 mm below the CEJ. The fracture toughness test was performed using UTM on the occlusal surface with a 0o tilt and crosshead of 1 mm/min. Results: The fracture toughness results of group A, B, and C are 735.44, 756.78, and 829 respectively. Statistical tests with one-way ANOVA showed no significant difference with p value = 0.412 (p < 0.05). Conclusion: There is no difference in resistance of the intracanal retention thickness with flowable fiber reinforced composite materials towards fracture toughness.Keywords: post-RCT treatments, intracanal retentions, SFRC, fracture toughness","PeriodicalId":31757,"journal":{"name":"Padjadjaran Journal of Dentistry","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Padjadjaran Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24198/pjd.vol35no1.45151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACTIntroduction: Dental hard tissue problems were relatively high in Indonesia. If these problems were ignored, they would cause pulpal necrosis. The main treatment for this case was Root Canal Treatment (RCT). The selection of post-RCT treatment and suitable materials was important. One of the examples was short fiber reinforced composite (SFRC) which can be an option for intracanal retention treatment. This study aims to analyze the resistance of the intracanal retention thickness with flowable fiber reinforced composite materials toward fracture toughness. Methods: This research was using a correlative laboratory experimental method with a post-test group-only design. This study's samples were SFRC material inserted in 27 extracted mandibular first premolars with a length of 21 mm ± 2 mm and root canal walls width of 2 mm. All samples were given intracanal retention at a depth of 2 mm below the orifice and divided into 3 groups: intracanal retention with thickness of (A) 6 mm, (B) 5 mm, and (C) 4 mm. RCT was performed using the crown-down technique. The bonding agent was applied, and then light cured for 20 seconds. SFRC was applied according to the sample group and light cured for 20 seconds per 2 mm, followed by filling with composite resin. The sample was implanted in the dental stone 2 mm below the CEJ. The fracture toughness test was performed using UTM on the occlusal surface with a 0o tilt and crosshead of 1 mm/min. Results: The fracture toughness results of group A, B, and C are 735.44, 756.78, and 829 respectively. Statistical tests with one-way ANOVA showed no significant difference with p value = 0.412 (p < 0.05). Conclusion: There is no difference in resistance of the intracanal retention thickness with flowable fiber reinforced composite materials towards fracture toughness.Keywords: post-RCT treatments, intracanal retentions, SFRC, fracture toughness
流动短纤维增强复合材料(SFRC)管内保留厚度对断裂韧性的阻力
摘要简介:印度尼西亚牙硬组织疾病发病率较高。如果忽视这些问题,就会引起牙髓坏死。本病例的主要治疗是根管治疗(RCT)。选择rct后的处理方法和合适的材料是重要的。其中一个例子是短纤维增强复合材料(SFRC),它可以作为肛管内潴留治疗的一种选择。本研究旨在分析流动纤维增强复合材料管内保留厚度对断裂韧性的阻力。方法:采用相关实验室实验方法,采用单组设计。本研究采用SFRC材料植入27颗拔除的下颌第一前磨牙,其长度为21 mm±2 mm,根管壁宽度为2 mm。所有样本均在孔口以下2mm处留置,分为3组:留置厚度(a) 6mm, (B) 5mm, (C) 4mm。采用crown-down技术进行随机对照试验。涂上粘结剂,然后光固化20秒。根据样品组涂抹SFRC,每2 mm光固化20秒,然后填充复合树脂。将样品植入到牙石中,牙石位于CEJ下方2mm处。采用UTM在咬合面上进行断裂韧性测试,咬合面倾斜度为0,十字头为1 mm/min。结果:A、B、C组的断裂韧性分别为735.44、756.78、829。经单因素方差分析,p值= 0.412,差异无统计学意义(p < 0.05)。结论:流动纤维增强复合材料对管内保留厚度对断裂韧性的阻力无显著差异。关键词:rct后治疗,管内保留,SFRC,断裂韧性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
26
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信