Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters

IF 0.3 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Habibe Öztürk, Y. Deniz, Çağatay Aktaş, Esma Başak GÜL AYGÜN
{"title":"Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters","authors":"Habibe Öztürk, Y. Deniz, Çağatay Aktaş, Esma Başak GÜL AYGÜN","doi":"10.33808/clinexphealthsci.1194836","DOIUrl":null,"url":null,"abstract":"Objective: This study aimed to assess the effects of denture materials on dose distribution on a head and neck radiotherapy-appropriate model and calculate the thickness of a stent by polyvinyl siloxane dental impression material for shielding scattered radiation from dental restorations. \nMethods: In the first step of the study, 5mm diameter and 5mm height of cylindrical dental material of titanium, zirconia lithium disilicate were irradiated with 6-Megavoltage photons from a clinical linear accelerator. In the second step, dental materials at the center of polyvinyl siloxane thicknesses of 5, 10, and 20mm were irradiated with 2 Gray and 10 Gray fractional doses. Measurements were made using three thermoluminescent dosimeters positioned laterally. The percentage backscattered dose and percentage dose decrease values were calculated to interpret the results. \nResults: According to the result, dosages scattered from dental materials increased for samples irradiated with 2Gy; a decreased dose was reported for samples irradiated with a 10Gy. 5mm PVS samples provided higher dose attenuation than others. Regardless of dental material, it is seen that the attenuation intensities calculated from TLD-100 dosimeters ranged from 22.7 to 38,62 for 2Gy, and 10.01 to 38,87 for 10Gy. \nConclusion: Dental material alters the scattered radiation. In irradiated head and neck cancer patients, a 5mm thick guard is sufficient to prevent radiation diffused from dental materials in clinical usage.","PeriodicalId":10192,"journal":{"name":"Clinical and Experimental Health Sciences","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33808/clinexphealthsci.1194836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to assess the effects of denture materials on dose distribution on a head and neck radiotherapy-appropriate model and calculate the thickness of a stent by polyvinyl siloxane dental impression material for shielding scattered radiation from dental restorations. Methods: In the first step of the study, 5mm diameter and 5mm height of cylindrical dental material of titanium, zirconia lithium disilicate were irradiated with 6-Megavoltage photons from a clinical linear accelerator. In the second step, dental materials at the center of polyvinyl siloxane thicknesses of 5, 10, and 20mm were irradiated with 2 Gray and 10 Gray fractional doses. Measurements were made using three thermoluminescent dosimeters positioned laterally. The percentage backscattered dose and percentage dose decrease values were calculated to interpret the results. Results: According to the result, dosages scattered from dental materials increased for samples irradiated with 2Gy; a decreased dose was reported for samples irradiated with a 10Gy. 5mm PVS samples provided higher dose attenuation than others. Regardless of dental material, it is seen that the attenuation intensities calculated from TLD-100 dosimeters ranged from 22.7 to 38,62 for 2Gy, and 10.01 to 38,87 for 10Gy. Conclusion: Dental material alters the scattered radiation. In irradiated head and neck cancer patients, a 5mm thick guard is sufficient to prevent radiation diffused from dental materials in clinical usage.
热辐射剂量计用于头颈部放射治疗的聚乙烯硅氧烷牙科印模防护罩剂量分布的研究
目的:本研究旨在评估义齿材料对头颈部放疗适当模型上剂量分布的影响,并计算聚乙烯基硅氧烷牙科印模材料支架的厚度,以屏蔽牙科修复体的散射辐射。方法:在研究的第一步中,用来自临床线性加速器的6兆伏光子照射直径为5毫米、高度为5毫米的钛、氧化锆二硅酸锂圆柱形牙科材料。在第二步骤中,用2格雷和10格雷分剂量照射厚度为5、10和20mm的聚乙烯基硅氧烷中心的牙科材料。使用三个横向放置的热致发光剂量计进行测量。计算反向散射剂量百分比和剂量减少百分比值来解释结果。结果:2Gy照射后,牙科材料散射剂量增加;报道了用10Gy照射的样品的剂量降低。5mm PVS样品提供了比其他样品更高的剂量衰减。不管牙科材料如何,可以看出,对于2Gy,TLD-100剂量计计算的衰减强度范围为22.7至38,62,对于10Gy,衰减强度为10.01至38,87。结论:牙科材料改变了散射辐射。在癌症头部和颈部受辐射的患者中,在临床使用中,5mm厚的防护装置足以防止辐射从牙科材料扩散。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical and Experimental Health Sciences
Clinical and Experimental Health Sciences MEDICINE, RESEARCH & EXPERIMENTAL-
自引率
0.00%
发文量
73
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信