Comparing the Temperature Effect of Dedicated Minimally Invasive Motor System to the Discontinuous Use of Rotatory Burrs in the Correction of Hallux Valgus

IF 1.8 Q2 ORTHOPEDICS
D. Robinson, E. Heller, M. Yassin
{"title":"Comparing the Temperature Effect of Dedicated Minimally Invasive Motor System to the Discontinuous Use of Rotatory Burrs in the Correction of Hallux Valgus","authors":"D. Robinson, E. Heller, M. Yassin","doi":"10.1177/1938640019890225","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to compare 2 motor systems for percutaneous osteotomy. The study consisted of 2 stages. In the first stage, bone temperatures during osteotomy using burrs or saw was measured using a thermal camera. In the second stage, the tissue and burr temperature elevation during surgery in 80 consecutive patients (96 feet) with hallux valgus undergoing distal first metatarsal and phalangeal osteotomies (hallux and in 61/96 feet lesser digits) were measured. The burr osteotomy procedure included the use of irrigated 2- or 4.1 mm rotary wedge burrs in discontinuous cutting bursts of less than 20 seconds. Tissue surface temperature was measured with a thermal camera. The temperature generated during the procedure was found to be significantly associated with the burr diameter used but was not affected by the type of motor. At the 6-week visit, thickness of the soft tissues over the first metatarsal head was similar in both groups. Temperature control using a noninvasive thermal camera is recommended to prevent tissue damage associated with heat generated during the use of rotary burrs. A dedicated low-speed high-torque system does not seem to be necessary and standard orthopaedic equipment can be used. Levels of Evidence: Level II: Comparative prospectively collected series","PeriodicalId":39271,"journal":{"name":"Foot and Ankle Specialist","volume":"13 1","pages":"478 - 487"},"PeriodicalIF":1.8000,"publicationDate":"2019-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1938640019890225","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Specialist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1938640019890225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 3

Abstract

The purpose of this study was to compare 2 motor systems for percutaneous osteotomy. The study consisted of 2 stages. In the first stage, bone temperatures during osteotomy using burrs or saw was measured using a thermal camera. In the second stage, the tissue and burr temperature elevation during surgery in 80 consecutive patients (96 feet) with hallux valgus undergoing distal first metatarsal and phalangeal osteotomies (hallux and in 61/96 feet lesser digits) were measured. The burr osteotomy procedure included the use of irrigated 2- or 4.1 mm rotary wedge burrs in discontinuous cutting bursts of less than 20 seconds. Tissue surface temperature was measured with a thermal camera. The temperature generated during the procedure was found to be significantly associated with the burr diameter used but was not affected by the type of motor. At the 6-week visit, thickness of the soft tissues over the first metatarsal head was similar in both groups. Temperature control using a noninvasive thermal camera is recommended to prevent tissue damage associated with heat generated during the use of rotary burrs. A dedicated low-speed high-torque system does not seem to be necessary and standard orthopaedic equipment can be used. Levels of Evidence: Level II: Comparative prospectively collected series
微创专用运动系统与不连续使用旋转突矫正Hallux Valgus的温度效应比较
本研究的目的是比较经皮截骨的两种运动系统。研究分为两个阶段。在第一阶段,在使用毛刺或锯进行截骨期间,使用热像仪测量骨温度。在第二阶段,测量了连续80名(96英尺)接受第一跖骨和指骨远端截骨的拇外翻患者(拇和61/96英尺小指)手术期间的组织和毛刺温度升高。毛刺截骨程序包括在不到20秒的不连续切割中使用灌注的2或4.1毫米旋转楔形毛刺。用热像仪测量组织表面温度。发现在该过程中产生的温度与所使用的毛刺直径显著相关,但不受电机类型的影响。在6周的随访中,两组第一跖骨头上的软组织厚度相似。建议使用非侵入式热像仪进行温度控制,以防止在使用旋转毛刺时产生与热量相关的组织损伤。专用的低速高扭矩系统似乎没有必要,可以使用标准的整形外科设备。证据水平:第二级:前瞻性收集的比较系列
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Foot and Ankle Specialist
Foot and Ankle Specialist Health Professions-Podiatry
CiteScore
3.10
自引率
0.00%
发文量
100
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信