Tianyu Song, Chang Chen, Shaoheng Bao, Bin Du, Xiaokun Wang, Jiajia Liu, Fuli Wang, Wei Ma, G. Yao, Xiukun Wan, Xinlong Zhang, JingJing Wang, Hui Jiang
{"title":"An immobilization-based, loop-mediated isothermal amplification device for nucleic acid detection of SARS-CoV-2 N gene","authors":"Tianyu Song, Chang Chen, Shaoheng Bao, Bin Du, Xiaokun Wang, Jiajia Liu, Fuli Wang, Wei Ma, G. Yao, Xiukun Wan, Xinlong Zhang, JingJing Wang, Hui Jiang","doi":"10.1080/13102818.2022.2134822","DOIUrl":null,"url":null,"abstract":"Abstract Confronting the global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), simple, fast and specific non-laboratory SARS-CoV-2 diagnostic tests are urgently required. However, the current nucleic acid assays generally rely on the diagnostic laboratory, trained staff and specialized equipment for execution and analysis, presenting clear limitations in the field detection. Here, we describe a portable and reliable immobilization-based loop-mediated isothermal amplification (LAMP) device which is mobile, without the requirement of any complicated instrument and appropriate for high-throughput testing. This device was constructed by utilizing the interaction between a carboxyl-tagged primer and an amino-tagged substrate, and capable of catching the target sequence in SARS-CoV-2 produced via the immobilization-based LAMP. In this study, the immobilization conditions and immobilized primer structure were explored and optimized. With this proposed device, the analysis result can be obtained rapidly in 30 min with excellent specificity, even if the template is extracted from a complex sample containing pharyngeal swab or human blood. In addition, the device can be applied to detect the nucleic acid of SARS-CoV-2 and various other pathogens, showing attractive potential for rapid and high-throughput detection at airports, railway stations, cold-chain transportations, community hospitals and so on. Therefore, we believe that the immobilization-based LAMP device is an advanced approach to developing a portable, specific, low-cost and high-throughput diagnostic platform.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/13102818.2022.2134822","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Confronting the global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), simple, fast and specific non-laboratory SARS-CoV-2 diagnostic tests are urgently required. However, the current nucleic acid assays generally rely on the diagnostic laboratory, trained staff and specialized equipment for execution and analysis, presenting clear limitations in the field detection. Here, we describe a portable and reliable immobilization-based loop-mediated isothermal amplification (LAMP) device which is mobile, without the requirement of any complicated instrument and appropriate for high-throughput testing. This device was constructed by utilizing the interaction between a carboxyl-tagged primer and an amino-tagged substrate, and capable of catching the target sequence in SARS-CoV-2 produced via the immobilization-based LAMP. In this study, the immobilization conditions and immobilized primer structure were explored and optimized. With this proposed device, the analysis result can be obtained rapidly in 30 min with excellent specificity, even if the template is extracted from a complex sample containing pharyngeal swab or human blood. In addition, the device can be applied to detect the nucleic acid of SARS-CoV-2 and various other pathogens, showing attractive potential for rapid and high-throughput detection at airports, railway stations, cold-chain transportations, community hospitals and so on. Therefore, we believe that the immobilization-based LAMP device is an advanced approach to developing a portable, specific, low-cost and high-throughput diagnostic platform.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.