V. Jobin, A. Mathieu, P. Rompré, Mélanie Perraton-Brillon, Geneviève Rondeau, P. Mayer
{"title":"Accuracy of the Oxford Sleep Resistance Test versus Simultaneous Electroencephalography to Detect Sleep Onset","authors":"V. Jobin, A. Mathieu, P. Rompré, Mélanie Perraton-Brillon, Geneviève Rondeau, P. Mayer","doi":"10.4172/2167-0277.1000257","DOIUrl":null,"url":null,"abstract":"Background: The Oxford Sleep Resistance test (OSLER) is a useful tool to assess daytime vigilance. However, \n it has not been validated against simultaneous electroencephalography (EEG) recordings in large populations. The \n main objective of the study was to compare the OSLER values versus EEG-determined Sleep Onset latency (EEGSOL). \nMethods: Patients referred for assessment of daytime vigilance were recruited from a tertiary sleep clinic. \n Patients underwent the OSLER (4 x 40 minutes trials; if 7 consecutive stimuli are missed, the trial is terminated and \n sleep onset is concluded to have occurred) with simultaneous EEG recordings. Determination of EEG-SOL using \n American Academy of sleep Medicine (AASM) criteria to score sleep during daytime testing was compared to \n OSLER values. \nResults: 65 OSLER were performed in 65 subjects for a total of 260 trials (65X4 trials/OSLER). In 136 out of the \n 260 trials (52.3%), subjects remained awake according to the OSLER, while EEG-SOL was scored in 5 of the 136 \n trials (3.7%). Of the 124 trials (47.7%) with sleep onset, (i.e. 7 consecutive missed stimuli) the mean sleep onset \n value was 14.5 ± 10.9 min and EEG-SOL was recorded before the end of the trial in 37 trials (29.8%) (Mean \n difference EEG-SOL vs. OSLER 4.1 ± 5.8 min). \nConclusion: Using current AASM criteria for daytime testing, EEG-determined sleep onset latency is unlikely to \n occur in subjects with no sleep onset in the OSLER. However, the presence of sleep onset in the OSLER cannot be \n used as a precise surrogate to detect EEG sleep onset.","PeriodicalId":73946,"journal":{"name":"Journal of sleep disorders & therapy","volume":" ","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of sleep disorders & therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2167-0277.1000257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Background: The Oxford Sleep Resistance test (OSLER) is a useful tool to assess daytime vigilance. However,
it has not been validated against simultaneous electroencephalography (EEG) recordings in large populations. The
main objective of the study was to compare the OSLER values versus EEG-determined Sleep Onset latency (EEGSOL).
Methods: Patients referred for assessment of daytime vigilance were recruited from a tertiary sleep clinic.
Patients underwent the OSLER (4 x 40 minutes trials; if 7 consecutive stimuli are missed, the trial is terminated and
sleep onset is concluded to have occurred) with simultaneous EEG recordings. Determination of EEG-SOL using
American Academy of sleep Medicine (AASM) criteria to score sleep during daytime testing was compared to
OSLER values.
Results: 65 OSLER were performed in 65 subjects for a total of 260 trials (65X4 trials/OSLER). In 136 out of the
260 trials (52.3%), subjects remained awake according to the OSLER, while EEG-SOL was scored in 5 of the 136
trials (3.7%). Of the 124 trials (47.7%) with sleep onset, (i.e. 7 consecutive missed stimuli) the mean sleep onset
value was 14.5 ± 10.9 min and EEG-SOL was recorded before the end of the trial in 37 trials (29.8%) (Mean
difference EEG-SOL vs. OSLER 4.1 ± 5.8 min).
Conclusion: Using current AASM criteria for daytime testing, EEG-determined sleep onset latency is unlikely to
occur in subjects with no sleep onset in the OSLER. However, the presence of sleep onset in the OSLER cannot be
used as a precise surrogate to detect EEG sleep onset.
背景:牛津睡眠抵抗测试(OSLER)是评估白天警惕性的有用工具。然而,它还没有针对大规模人群的同时脑电图(EEG)记录进行验证。本研究的主要目的是比较OSLER值与EEG确定的睡眠发作潜伏期(EEGSOL)。方法:从一家三级睡眠诊所招募接受日间警惕性评估的患者。患者接受OSLER(4 x 40分钟试验;如果错过7个连续刺激,则试验终止,并得出睡眠发作的结论),同时进行脑电图记录。将使用美国睡眠医学学会(AAM)标准对白天测试期间的睡眠进行评分的EEG-SOL的测定与OSLER值进行比较。结果:65名受试者进行了65次OSLER,共260项试验(65X4项试验/OSLER)。在260项试验中的136项(52.3%)中,受试者根据OSLER保持清醒,而在136项试验中有5项(3.7%)对EEG-SOL进行了评分。在124项有睡眠开始的试验(即连续7次错过刺激)中,平均睡眠开始值为14.5±10.9分钟,37项试验(29.8%)在试验结束前记录了EEG-SOL。OSLER 4.1±5.8分钟)。结论:使用目前的AASM日间测试标准,EEG确定的睡眠发作潜伏期不太可能发生在OSLER中没有睡眠发作的受试者中。然而,OSLER中睡眠发作的存在不能作为检测EEG睡眠发作的精确替代品。