Effect of Self-Cured and Self-Etch Adhesive Systems on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers

Q3 Dentistry
Ayşe Çeşme, İ. Hubbezoğlu
{"title":"Effect of Self-Cured and Self-Etch Adhesive Systems on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers","authors":"Ayşe Çeşme, İ. Hubbezoğlu","doi":"10.7126/cumudj.1299029","DOIUrl":null,"url":null,"abstract":"Effect of Self-Cured and Self-Etch Adhesive System on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers \n \nAyşe Çeşme1-a*, Ihsan Hubbezoğlu1-b \n1 Sivas Cumhuriyet University, Faculty of Dentistry, Department of Restorative Dentistry Sivas, Türkiye. \n \nABSTRACT \nObjectives: The aim of this study was to investigate the strength of shear bonding of self-cured and self-etch adhesive systems to dentin after surface disinfection with Photodynamic Therapy (PDT), Er:YAG, Nd:YAG, and KTP laser. \nMaterials and Methods: In the study, 6 main-groups were formed as Control, Er:YAG Laser, Nd: YAG Laser, KTP Laser, KTP Laser activated PDT and Diode Laser activated PDT. Each group was divided into two subgroups; Self-cured (Tokuyama Universal) and self-etch (Scotchbond Universal) adhesive system(n=10). 120 molar teeth were prepared to expose dentin surfaces. After disinfection and adhesive application, nanohybrid composite resin with a diameter of 3 mm and a height of 2 mm was applied to the dentin surface with the help of transparent molds. All samples were thermally cycled 5.000 times at 5°C and 55°C. Shear bond strength (SBS) test was applied to the samples in a universal test device. \nResults: The differences between the Er:YAG laser group and the control, KTP and Nd:YAG laser groups of the self-cured adhesive samples were statistically significant. While the differences between the Nd:YAG laser group and the PDT groups were statistically significant (p","PeriodicalId":10781,"journal":{"name":"Cumhuriyet Dental Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cumhuriyet Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7126/cumudj.1299029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Effect of Self-Cured and Self-Etch Adhesive System on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers Ayşe Çeşme1-a*, Ihsan Hubbezoğlu1-b 1 Sivas Cumhuriyet University, Faculty of Dentistry, Department of Restorative Dentistry Sivas, Türkiye. ABSTRACT Objectives: The aim of this study was to investigate the strength of shear bonding of self-cured and self-etch adhesive systems to dentin after surface disinfection with Photodynamic Therapy (PDT), Er:YAG, Nd:YAG, and KTP laser. Materials and Methods: In the study, 6 main-groups were formed as Control, Er:YAG Laser, Nd: YAG Laser, KTP Laser, KTP Laser activated PDT and Diode Laser activated PDT. Each group was divided into two subgroups; Self-cured (Tokuyama Universal) and self-etch (Scotchbond Universal) adhesive system(n=10). 120 molar teeth were prepared to expose dentin surfaces. After disinfection and adhesive application, nanohybrid composite resin with a diameter of 3 mm and a height of 2 mm was applied to the dentin surface with the help of transparent molds. All samples were thermally cycled 5.000 times at 5°C and 55°C. Shear bond strength (SBS) test was applied to the samples in a universal test device. Results: The differences between the Er:YAG laser group and the control, KTP and Nd:YAG laser groups of the self-cured adhesive samples were statistically significant. While the differences between the Nd:YAG laser group and the PDT groups were statistically significant (p
自固化和自蚀刻粘合剂体系对不同类型激光光动力治疗和消毒后剪切结合强度的影响
自固化和自蚀刻胶粘剂体系对不同类型激光光动力治疗和消毒后剪切结合强度的影响[] Çeşme1-a*, Ihsan Hubbezoğlu1-b 1捷克锡瓦斯大学牙科学院,锡瓦斯修复牙科学系, rkiye。摘要目的:研究光动力疗法(PDT)、Er:YAG、Nd:YAG和KTP激光对牙本质表面消毒后,自固化和自蚀刻胶粘剂与牙本质的剪切结合强度。材料与方法:本研究分为对照组、Er:YAG激光器、Nd: YAG激光器、KTP激光器、KTP激光激活PDT和二极管激光激活PDT 6个主要组。每组又分为两个亚组;自固化(Tokuyama Universal)和自蚀刻(Scotchbond Universal)粘合剂系统(n=10)。预备120颗磨牙,暴露牙本质表面。消毒、粘接后,借助透明模具将直径为3mm、高度为2mm的纳米杂化复合树脂涂于牙本质表面。所有样品在5°C和55°C下热循环5000次。在通用试验装置上对试样进行剪切粘结强度(SBS)试验。结果:Er:YAG激光组与自固化胶粘剂样品的对照组、KTP、Nd:YAG激光组比较差异均有统计学意义。而Nd:YAG激光组与PDT组之间的差异有统计学意义(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cumhuriyet Dental Journal
Cumhuriyet Dental Journal Dentistry-Dentistry (all)
CiteScore
0.40
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信