Comparison of force decay pattern in orthodontic elastomeric chains and NiTi closed coil springs, affected by five different mouthwashes: An in vitro Study

Q4 Dentistry
A. Mirhashemi, Niloofar Habibi Khameneh, Keyvan Shahpoorzadeh, A. Saffar Shahroudi
{"title":"Comparison of force decay pattern in orthodontic elastomeric chains and NiTi closed coil springs, affected by five different mouthwashes: An in vitro Study","authors":"A. Mirhashemi, Niloofar Habibi Khameneh, Keyvan Shahpoorzadeh, A. Saffar Shahroudi","doi":"10.5195/d3000.2021.158","DOIUrl":null,"url":null,"abstract":"Background: The aim of this study was to compare the force decay pattern of elastomeric chains and NiTi coil springs which were exposed to five different commercially available mouthwashes.Methods: In this in vitro study, 60 pieces of elastomeric chain (EC) and 60 NiTi closed coil springs (CS) were divided into 6 groups. The specimens were exposed to one of these mouthwashes twice a day for 60 seconds:  Listerine, chlorhexidine, Orthokin, Persica, fluoride and artificial saliva as the control group. The elastomeric chains and NiTi springs were stretched so that they exert the initial force of 250 gr. Their force was measured on the 1, 7, 14 and 28 following days by means of a digital gauge.Results: Elastomeric chains and coil springs had force decrease over time, but EC' force reduction was greater with the highest reduction rate in the first week. However, in the CS group, the force decrease wasn't statistically significant in the first two weeks.  After 28 days in the control groups, 49.8% of the initial force was remained in ECs while the value was 93.3% for CSs. In comparison between mouthwashes, in EC groups, in all mouthwashes except Persica, the remained force was statistically less than control group.Conclusion: Force degradation of elastomeric chains could be exacerbated by use of mouthwashes. About coil springs, force decay was also observed. However, it was not statistically significant. Force reduction was detectable after four weeks of coil springs usage, but in EC groups, the greatest reduction was after the first week.  ","PeriodicalId":37056,"journal":{"name":"Dentistry 3000","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry 3000","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5195/d3000.2021.158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 4

Abstract

Background: The aim of this study was to compare the force decay pattern of elastomeric chains and NiTi coil springs which were exposed to five different commercially available mouthwashes.Methods: In this in vitro study, 60 pieces of elastomeric chain (EC) and 60 NiTi closed coil springs (CS) were divided into 6 groups. The specimens were exposed to one of these mouthwashes twice a day for 60 seconds:  Listerine, chlorhexidine, Orthokin, Persica, fluoride and artificial saliva as the control group. The elastomeric chains and NiTi springs were stretched so that they exert the initial force of 250 gr. Their force was measured on the 1, 7, 14 and 28 following days by means of a digital gauge.Results: Elastomeric chains and coil springs had force decrease over time, but EC' force reduction was greater with the highest reduction rate in the first week. However, in the CS group, the force decrease wasn't statistically significant in the first two weeks.  After 28 days in the control groups, 49.8% of the initial force was remained in ECs while the value was 93.3% for CSs. In comparison between mouthwashes, in EC groups, in all mouthwashes except Persica, the remained force was statistically less than control group.Conclusion: Force degradation of elastomeric chains could be exacerbated by use of mouthwashes. About coil springs, force decay was also observed. However, it was not statistically significant. Force reduction was detectable after four weeks of coil springs usage, but in EC groups, the greatest reduction was after the first week.  
五种不同漱口水对正畸弹性体链和镍钛封闭螺旋弹簧力衰减模式的影响
背景:本研究的目的是比较五种不同的市售漱口水对弹性体链和镍钛螺旋弹簧的力衰减模式。方法:采用体外实验方法,将60根弹性体链(EC)和60根NiTi闭合螺旋弹簧(CS)分为6组。这些标本每天两次暴露于以下漱口水中的一种,每次60秒:李斯德林、氯己定、Orthokin、Persica、氟化物和人工唾液作为对照组。橡胶链和镍钛弹簧被拉伸,使它们施加250克的初始力。它们的力在随后的1、7、14和28天通过数字仪表测量。结果:弹性链和螺旋弹簧的受力随时间的推移而降低,但EC的受力降低幅度更大,第一周的降幅最大。然而,在CS组中,力的下降在前两周没有统计学意义。对照组28 d后,ECs保留了49.8%的初始力,而CSs保留了93.3%的初始力。在漱口水之间的比较中,EC组中除Persica外,所有漱口水的剩余力均低于对照组。结论:使用漱口水可加剧弹性链的受力退化。对于螺旋弹簧,也观察到力衰减。然而,这在统计学上并不显著。在使用螺旋弹簧四周后,可以检测到力的减少,但在EC组中,最大的减少是在第一周后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dentistry 3000
Dentistry 3000 Dentistry-Dentistry (all)
CiteScore
0.40
自引率
0.00%
发文量
25
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信