{"title":"Simple HPLC method for simultaneous quantification of nicotine and cotinine levels in rat plasma after exposure to two different tobacco products","authors":"Ala A. Alhusban, A. Hammad, Lujain F. Alzaghari","doi":"10.1556/1326.2022.01054","DOIUrl":null,"url":null,"abstract":"\n \n \n Development and validation of a selective analytical method to accurately and precisely quantify nicotine and cotinine levels in rat's plasma after exposure to tobacco cigarettes and tobacco water-pipe.\n \n \n \n An easy HPLC-Photodiode-Array Detection (PDA) method was developed and validated for simultaneous determination of nicotine and cotinine levels in plasma of 15 rats (10 rats after tobacco products exposure and 5 control rats). Nicotine and cotinine were extracted in one step from plasma using acetonitrile and concentrated to lowest volume using nitrogen stream.\n \n \n \n The developed method offered a rapid analysis time of 14 min with single step of analytes extraction from rat's plasma with recovery percentage range between 93 and 95% and excellent linearity with correlation factor more than 0.994 with analytical range between 50 and 1000 ng mL−1 and LOD of 25 ng mL−1 and 23 ng mL−1 for nicotine and cotinine, respectively. The analysis of rat's plasma after 28 days of exposure to tobacco cigarettes and tobacco water-pipe revealed that the average concentrations of 376 ng mL−1 for cotinine and 223 ng mL−1 for nicotine were obtained after tobacco cigarettes exposure, and 220 ng mL−1 for cotinine and 192 ng mL−1 for nicotine after tobacco water-pipe exposure.\n \n \n \n Higher nicotine and cotinine levels were found in plasma after tobacco cigarettes exposure than water-pipe exposure which may have potential undesirable effects on passive smokers in both cases.\n","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2022-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.01054","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 4
Abstract
Development and validation of a selective analytical method to accurately and precisely quantify nicotine and cotinine levels in rat's plasma after exposure to tobacco cigarettes and tobacco water-pipe.
An easy HPLC-Photodiode-Array Detection (PDA) method was developed and validated for simultaneous determination of nicotine and cotinine levels in plasma of 15 rats (10 rats after tobacco products exposure and 5 control rats). Nicotine and cotinine were extracted in one step from plasma using acetonitrile and concentrated to lowest volume using nitrogen stream.
The developed method offered a rapid analysis time of 14 min with single step of analytes extraction from rat's plasma with recovery percentage range between 93 and 95% and excellent linearity with correlation factor more than 0.994 with analytical range between 50 and 1000 ng mL−1 and LOD of 25 ng mL−1 and 23 ng mL−1 for nicotine and cotinine, respectively. The analysis of rat's plasma after 28 days of exposure to tobacco cigarettes and tobacco water-pipe revealed that the average concentrations of 376 ng mL−1 for cotinine and 223 ng mL−1 for nicotine were obtained after tobacco cigarettes exposure, and 220 ng mL−1 for cotinine and 192 ng mL−1 for nicotine after tobacco water-pipe exposure.
Higher nicotine and cotinine levels were found in plasma after tobacco cigarettes exposure than water-pipe exposure which may have potential undesirable effects on passive smokers in both cases.
一种选择性分析方法的开发和验证,该方法可准确准确地定量大鼠接触烟草香烟和烟草水管后血浆中的尼古丁和可替宁水平。开发并验证了一种简单的HPLC光电二极管阵列检测(PDA)方法,用于同时测定15只大鼠(10只烟草制品暴露后的大鼠和5只对照大鼠)血浆中的尼古丁和可替宁水平。使用乙腈一步从血浆中提取尼古丁和可替宁,并使用氮气流浓缩至最低体积。所开发的方法提供了14的快速分析时间 min,从大鼠血浆中一步提取分析物,回收率在93%至95%之间,线性良好,相关系数大于0.994,分析范围在50至1000之间 ng mL−1,LOD为25 ng mL−1和23 尼古丁和可替宁分别为ng mL−1。对暴露于烟草香烟和烟草水管28天后大鼠血浆的分析显示,376 ng mL−1用于可替宁和223 尼古丁的浓度为ng mL−1,在接触烟草香烟后,浓度为220 ng mL−1用于可替宁和192 烟草水管暴露后尼古丁浓度为ng mL−1。烟草烟雾暴露后血浆中的尼古丁和可替宁水平高于水管暴露,这可能对被动吸烟者产生潜在的不良影响。
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.