Optic nerve sheath diameter and its implications in the evaluation of cerebral venous sinus thrombosis

S. Das, S. Jindal, Vikram Patil, Sachin T.
{"title":"Optic nerve sheath diameter and its implications in the evaluation of cerebral venous sinus thrombosis","authors":"S. Das, S. Jindal, Vikram Patil, Sachin T.","doi":"10.5114/pjr.2022.115706","DOIUrl":null,"url":null,"abstract":"Purpose To ascertain the role of optic nerve sheath diameter (ONSD) in the evaluation of cerebral venous sinus thrombosis (CVST). Material and methods A retrospective study with convenient sampling was done during the period November 2018 to January 2020. Forty-one patients across all age groups with magnetic resonance venography (MRV) diagnosis of CVST and 82 gender-matched controls were included in the study. ONSD was measured on axial T2-weighted magnetic resonance images. CVST was identified on axial TOF-MRV including the stage, degree, and location. Intraparenchymal infarction and haemorrhage were also noted with their stage and size. The distribution of values for ONSD was tested for equality of variances using independent samples t-test. A cut-off value for ONSD was derived using ROC analysis. Results The mean difference between ONSD of cases and controls was 0.84 mm (95% CI: 0.61-1.06) and was statistically significant at p < 0.001. Mean ONSD in cases was 5.33 ± 0.66, and in the control group it was 4.49 ± 0.31. The cut-off value for ONSD was taken as 4.57 mm, derived using the ROC analysis (AUC was 0.876 suggesting good diagnostic accuracy). ONSD showed a sensitivity of 87% and a negative predictive value of 89% in predicting CVST. However, we found no statistical significance between ONSD in patients with acute or chronic thrombosis or in those with neuroparenchymal complications. Conclusions ONSD is a valid triage tool with high sensitivity and negative predictive value, and it can be used in the evaluation of CVST.","PeriodicalId":94174,"journal":{"name":"Polish journal of radiology","volume":"87 1","pages":"e202 - e206"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish journal of radiology","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.5114/pjr.2022.115706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose To ascertain the role of optic nerve sheath diameter (ONSD) in the evaluation of cerebral venous sinus thrombosis (CVST). Material and methods A retrospective study with convenient sampling was done during the period November 2018 to January 2020. Forty-one patients across all age groups with magnetic resonance venography (MRV) diagnosis of CVST and 82 gender-matched controls were included in the study. ONSD was measured on axial T2-weighted magnetic resonance images. CVST was identified on axial TOF-MRV including the stage, degree, and location. Intraparenchymal infarction and haemorrhage were also noted with their stage and size. The distribution of values for ONSD was tested for equality of variances using independent samples t-test. A cut-off value for ONSD was derived using ROC analysis. Results The mean difference between ONSD of cases and controls was 0.84 mm (95% CI: 0.61-1.06) and was statistically significant at p < 0.001. Mean ONSD in cases was 5.33 ± 0.66, and in the control group it was 4.49 ± 0.31. The cut-off value for ONSD was taken as 4.57 mm, derived using the ROC analysis (AUC was 0.876 suggesting good diagnostic accuracy). ONSD showed a sensitivity of 87% and a negative predictive value of 89% in predicting CVST. However, we found no statistical significance between ONSD in patients with acute or chronic thrombosis or in those with neuroparenchymal complications. Conclusions ONSD is a valid triage tool with high sensitivity and negative predictive value, and it can be used in the evaluation of CVST.
视神经鞘直径及其在脑静脉窦血栓形成评价中的意义
目的探讨视神经鞘直径(ONSD)在评价脑静脉窦血栓形成(CVST)中的作用。材料和方法在2018年11月至2020年1月期间进行了一项方便抽样的回顾性研究。研究包括41名所有年龄组的磁共振静脉造影(MRV)诊断为CVST的患者和82名性别匹配的对照组。在轴向T2加权磁共振图像上测量ONSD。在轴向TOF-MRV上识别CVST,包括分期、程度和位置。实质内梗死和出血也与它们的分期和大小有关。ONSD值的分布使用独立样本t检验来检验方差的相等性。使用ROC分析得出ONSD的临界值。结果病例和对照组的ONSD平均差异为0.84mm(95%可信区间:0.61-1.06),差异有统计学意义(p<0.001)。病例的平均ONSD为5.33±0.66,对照组为4.49±0.31。ONSD的截止值取4.57mm,使用ROC分析得出(AUC为0.876,表明诊断准确性良好)。ONSD预测CVST的敏感性为87%,阴性预测值为89%。然而,我们发现急性或慢性血栓形成患者或神经实质并发症患者的ONSD之间没有统计学意义。结论ONSD是一种有效的分型工具,具有较高的敏感性和阴性预测价值,可用于CVST的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信