Comparison of Outcomes After Septoplasty With Non-Absorbable or Biodegradable Synthetic Polyurethane Foam Nasal Packing With a Focus on Pain and Cardiac Factors.

Journal of Rhinology Pub Date : 2023-03-01 Epub Date: 2023-03-30 DOI:10.18787/jr.2023.00005
Jae Seong An, Do Hyun Kim, Soo Whan Kim, Sung Won Kim, Il Hwan Lee
{"title":"Comparison of Outcomes After Septoplasty With Non-Absorbable or Biodegradable Synthetic Polyurethane Foam Nasal Packing With a Focus on Pain and Cardiac Factors.","authors":"Jae Seong An, Do Hyun Kim, Soo Whan Kim, Sung Won Kim, Il Hwan Lee","doi":"10.18787/jr.2023.00005","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>We compared pain levels, cardiovascular parameters, and complications according to whether patients underwent nasal packing with non-absorbable or biodegradable materials.</p><p><strong>Methods: </strong>Patients who underwent septoplasty from May 2015 to April 2020 were retrospectively reviewed. Numeric rating scale (NRS) scores for pain, blood pressure, and heart rate were measured three times (immediately after surgery, 6 hours later, and on postoperative day [POD] 1). We collected data on complications, including postoperative bleeding, septal hematoma, adhesions, septal perforation, and the recurrence of septal deviation.</p><p><strong>Results: </strong>In total, 200 patients underwent septoplasty, of whom 100 underwent nasal packing with Merocel and 100 underwent packing with Nasopore. The summed NRS scores over the three time points did not differ significantly between the groups. The NRS scores at 6 hours after surgery were highest in both groups. The systolic and diastolic blood pressure and the heart rate immediately after surgery were significantly higher than before surgery in both groups. The blood pressure and heart rate at 6 hours after surgery and on POD 1 did not differ significantly from those before surgery in either group. The incidence of sleep disturbance, postoperative bleeding, septal hematoma, adhesions, septal perforation, and recurrence of septal deviation did not differ significantly between the two groups.</p><p><strong>Conclusion: </strong>Although the level of postoperative pain and the cardiovascular parameters changed over time, we found no significant differences in pain, blood pressure, heart rate, or the complication rate according to whether patients underwent nasal packing with Nasopore or Merocel.</p>","PeriodicalId":33935,"journal":{"name":"Journal of Rhinology","volume":" ","pages":"31-36"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11524360/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rhinology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18787/jr.2023.00005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objectives: We compared pain levels, cardiovascular parameters, and complications according to whether patients underwent nasal packing with non-absorbable or biodegradable materials.

Methods: Patients who underwent septoplasty from May 2015 to April 2020 were retrospectively reviewed. Numeric rating scale (NRS) scores for pain, blood pressure, and heart rate were measured three times (immediately after surgery, 6 hours later, and on postoperative day [POD] 1). We collected data on complications, including postoperative bleeding, septal hematoma, adhesions, septal perforation, and the recurrence of septal deviation.

Results: In total, 200 patients underwent septoplasty, of whom 100 underwent nasal packing with Merocel and 100 underwent packing with Nasopore. The summed NRS scores over the three time points did not differ significantly between the groups. The NRS scores at 6 hours after surgery were highest in both groups. The systolic and diastolic blood pressure and the heart rate immediately after surgery were significantly higher than before surgery in both groups. The blood pressure and heart rate at 6 hours after surgery and on POD 1 did not differ significantly from those before surgery in either group. The incidence of sleep disturbance, postoperative bleeding, septal hematoma, adhesions, septal perforation, and recurrence of septal deviation did not differ significantly between the two groups.

Conclusion: Although the level of postoperative pain and the cardiovascular parameters changed over time, we found no significant differences in pain, blood pressure, heart rate, or the complication rate according to whether patients underwent nasal packing with Nasopore or Merocel.

以疼痛和心脏因素为重点的不可吸收或可生物降解合成聚氨酯泡沫鼻中隔成形术后结果的比较
背景和目的:根据患者是否使用非吸收性或生物可降解材料进行鼻腔填塞,我们比较了疼痛程度、心血管参数和并发症。方法:对2015年5月至2020年4月接受鼻中隔成形术的患者进行回顾性分析。疼痛、血压和心率的数字评定量表(NRS)评分被测量了三次(手术后立即、6小时后和术后第[POD]1天)。我们收集了并发症的数据,包括术后出血、间隔血肿、粘连、间隔穿孔和间隔偏移复发。结果:共有200例患者接受了鼻中隔成形术,其中100例用Merocel鼻腔填塞,100例用Nasopore鼻腔填塞。三个时间点的NRS总分在各组之间没有显著差异。两组患者术后6小时的NRS评分最高。两组患者术后即刻的收缩压、舒张压和心率均显著高于术前。两组患者术后6小时和POD 1时的血压和心率均与术前无显著差异。睡眠障碍、术后出血、间隔血肿、粘连、间隔穿孔和间隔偏离复发的发生率在两组之间没有显著差异。结论:尽管术后疼痛程度和心血管参数会随着时间的推移而变化,但我们发现,根据患者是否使用Nasopore或Merocel鼻腔填塞,疼痛、血压、心率或并发症发生率没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
23
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信