Fuga paravalvular tras implante de ACURATE neo y neo2: estudio comparativo con cuantificaci�n de calcio

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
M. García-Guimarães, Dirk-Jan Van Ginkel, Benno J. Rensing, J. M. T. Berg, Uday Sonker, Thomas L. De Kroon, Robin H. Heijmen, Martin J. Swaans, L. Timmers
{"title":"Fuga paravalvular tras implante de ACURATE neo y neo2: estudio comparativo con cuantificaci�n de calcio","authors":"M. García-Guimarães, Dirk-Jan Van Ginkel, Benno J. Rensing, J. M. T. Berg, Uday Sonker, Thomas L. De Kroon, Robin H. Heijmen, Martin J. Swaans, L. Timmers","doi":"10.24875/recic.m23000369","DOIUrl":null,"url":null,"abstract":"Introduction and objectives: Moderate or severe paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) has been associated with worse outcomes. Aortic valve (AV) calcification is a strong predictor of PVL. ACURATE neo (Boston Scientific Corporation, United States) is a self-expanding transcatheter heart valve to treat degenerative aortic stenosis. We evaluated PVL after ACURATE neo and neo2 implantation, and the role of AV calcification. Methods: We analyzed patients referred for TAVI with ACURATE neo and neo2 from a large volume tertiary center. All cardiac computed tomography scans were analyzed using 3Mensio Structural Heart software (Pie Medical Imaging, The Netherlands). The volume of AV calcium was quantified using contrast-enhanced cardiac computed tomography series. The 30-day clinical and echocardiographic data were prospectively recorded. Results: We included 165 patients referred for TAVI with ACURATE (neo = 87; neo2 = 78). Median age was 82 years-old, 65% were women with a median EuroSCORE II of 4.7 [IQR, 2.4-6.1]. Patients in the neo group showed a larger amount of total AV calcium (320 mm 3 vs 200 mm 3 ; P = .0305). We found no significant inter-group differences regarding clinical outcomes both","PeriodicalId":34295,"journal":{"name":"REC Interventional Cardiology","volume":" ","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"REC Interventional Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/recic.m23000369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives: Moderate or severe paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) has been associated with worse outcomes. Aortic valve (AV) calcification is a strong predictor of PVL. ACURATE neo (Boston Scientific Corporation, United States) is a self-expanding transcatheter heart valve to treat degenerative aortic stenosis. We evaluated PVL after ACURATE neo and neo2 implantation, and the role of AV calcification. Methods: We analyzed patients referred for TAVI with ACURATE neo and neo2 from a large volume tertiary center. All cardiac computed tomography scans were analyzed using 3Mensio Structural Heart software (Pie Medical Imaging, The Netherlands). The volume of AV calcium was quantified using contrast-enhanced cardiac computed tomography series. The 30-day clinical and echocardiographic data were prospectively recorded. Results: We included 165 patients referred for TAVI with ACURATE (neo = 87; neo2 = 78). Median age was 82 years-old, 65% were women with a median EuroSCORE II of 4.7 [IQR, 2.4-6.1]. Patients in the neo group showed a larger amount of total AV calcium (320 mm 3 vs 200 mm 3 ; P = .0305). We found no significant inter-group differences regarding clinical outcomes both
Acurate Neo和NeO2植入后瓣膜旁渗漏:与钙定量的比较研究
简介和目的:经导管主动脉瓣植入术(TAVI)后中度或重度瓣旁漏(PVL)与较差的预后相关。主动脉瓣钙化是PVL的重要预测指标。accurate neo(波士顿科学公司,美国)是一种自我扩张的经导管心脏瓣膜,用于治疗退行性主动脉瓣狭窄。我们评估了acate neo和neo2植入后的PVL,以及房室钙化的作用。方法:我们分析来自大容量三级中心的acatate neo和neo2转诊TAVI的患者。所有心脏计算机断层扫描使用3Mensio心脏结构软件(Pie Medical Imaging, The Netherlands)进行分析。采用增强心脏计算机断层扫描系列定量测定房室钙的体积。前瞻性记录30天临床及超声心动图资料。结果:我们纳入了165例使用accurate进行TAVI转诊的患者(neo = 87;Neo2 = 78)。年龄中位数为82岁,65%为女性,EuroSCORE II中位数为4.7 [IQR, 2.4-6.1]。neo组患者的总房室钙含量更高(320 mm 3 vs 200 mm 3;P = .0305)。我们发现两组间临床结果没有显著差异
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
REC Interventional Cardiology
REC Interventional Cardiology Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.10
自引率
28.60%
发文量
87
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信