Influence different polishing systems on roughness and colour stability of chairside CAD/CAM blocks with laminate veneer thickness

R. Sasany, Göknil Ergün Kunt, Mehmet Faruk Koca
{"title":"Influence different polishing systems on roughness and colour stability of chairside CAD/CAM blocks with laminate veneer thickness","authors":"R. Sasany, Göknil Ergün Kunt, Mehmet Faruk Koca","doi":"10.1177/22808000221086493","DOIUrl":null,"url":null,"abstract":"Objective: The aim of this study was to evaluate the effect of different polishing systems on the colour stability of different laminate veneer blocks for chair-side CAD-CAM after ultraviolet (UV) ageing. Methods: About 240 sample (13 × 13 × 0.7) were prepared from four different CAD-CAM blocks IPS e.max CAD (IP), IPS Empress CAD (IE), Mark II (M) and Lava Ultimate (LU)) with A1 shade. Each group was divided into five subgroups (n = 12) according to the control (C) and four different polishing system: Sof-Lex (S), Edenta (E), Identoflex (I) and Zircon Brite (Z). Surface roughnesses (Ra) were measured by a profilometer before and after polishing. The baseline colour values were recorded according to the CIELab system. The colour coordinates (L*, a* and b*) of the samples were measured before and after UV ageing, and colour differences (ΔE00) were calculated by using the CIEDE2000 colour difference formula. A two-way ANOVA and Tukey test methods were used to analyse the data (α = 0.05). Results: A significant interaction was observed between CAD-CAM blocks and polishing system (p < 0.001). The higher Ra and colour difference was calculated in LU in the Z group after polished and the lower Ra and colour difference was calculated in the IP in the S group after polished. For the IP group, the glazing procedure showed higher Ra and ΔE values with Z group than polished S system, whereas there is no statistical differences. Conclusion: It is concluded that polishing with the Sof-Lex system improves significantly smoothness and colour stability. However, there is no success in using the Zircon Brite polishing system.","PeriodicalId":51074,"journal":{"name":"Journal of Applied Biomaterials & Biomechanics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomaterials & Biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/22808000221086493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Objective: The aim of this study was to evaluate the effect of different polishing systems on the colour stability of different laminate veneer blocks for chair-side CAD-CAM after ultraviolet (UV) ageing. Methods: About 240 sample (13 × 13 × 0.7) were prepared from four different CAD-CAM blocks IPS e.max CAD (IP), IPS Empress CAD (IE), Mark II (M) and Lava Ultimate (LU)) with A1 shade. Each group was divided into five subgroups (n = 12) according to the control (C) and four different polishing system: Sof-Lex (S), Edenta (E), Identoflex (I) and Zircon Brite (Z). Surface roughnesses (Ra) were measured by a profilometer before and after polishing. The baseline colour values were recorded according to the CIELab system. The colour coordinates (L*, a* and b*) of the samples were measured before and after UV ageing, and colour differences (ΔE00) were calculated by using the CIEDE2000 colour difference formula. A two-way ANOVA and Tukey test methods were used to analyse the data (α = 0.05). Results: A significant interaction was observed between CAD-CAM blocks and polishing system (p < 0.001). The higher Ra and colour difference was calculated in LU in the Z group after polished and the lower Ra and colour difference was calculated in the IP in the S group after polished. For the IP group, the glazing procedure showed higher Ra and ΔE values with Z group than polished S system, whereas there is no statistical differences. Conclusion: It is concluded that polishing with the Sof-Lex system improves significantly smoothness and colour stability. However, there is no success in using the Zircon Brite polishing system.
影响不同抛光系统对椅边CAD/CAM块的粗糙度和颜色稳定性
目的:本研究的目的是评估紫外线(UV)老化后,不同抛光系统对椅子侧CAD-CAM用不同层压单板块颜色稳定性的影响。方法:约240个样本(13 × 13 × 0.7)由具有A1阴影的四个不同的CAD-CAM块IPS e.max CAD(IP)、IPS Empress CAD(IE)、Mark II(M)和Lava Ultimate(LU)制备。每组分为5个亚组(n = 12) 根据对照(C)和四种不同的抛光系统:Sof Lex(S)、Edenta(E)、Identflex(I)和Zircon Brite(Z)。在抛光之前和之后通过轮廓仪测量表面粗糙度(Ra)。根据CIELab系统记录基线颜色值。在紫外线老化前后测量样品的色坐标(L*、a*和b*),并使用CIEDE2000色差公式计算色差(ΔE00)。采用双向方差分析和Tukey检验方法分析数据(α = 结果:CAD-CAM块与抛光系统之间存在显著的相互作用(p < 0.001)。抛光后Z组的LU中计算出较高的Ra和色差,而抛光后S组的IP中计算出较低的Ra和温差。对于IP组,Z组的上釉程序显示出比抛光S系统更高的Ra和ΔE值,但没有统计学差异。结论:Sof-Lex系统抛光显著提高了光滑度和颜色稳定性。然而,使用锆石Brite抛光系统并没有取得成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Biomaterials & Biomechanics
Journal of Applied Biomaterials & Biomechanics 生物-材料科学:生物材料
自引率
0.00%
发文量
0
审稿时长
12 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信