Irene Paganini, C. Sani, Chiara Chilleri, M. Baccini, Alberto Antonelli, S. Bisanzi, E. Burroni, F. Cellai, M. Coppi, F. Mealli, G. Pompeo, Jessica Viti, G. Rossolini, F. Carozzi
{"title":"Assessment of the feasibility of pool testing for SARS-CoV-2 infection screening","authors":"Irene Paganini, C. Sani, Chiara Chilleri, M. Baccini, Alberto Antonelli, S. Bisanzi, E. Burroni, F. Cellai, M. Coppi, F. Mealli, G. Pompeo, Jessica Viti, G. Rossolini, F. Carozzi","doi":"10.1080/23744235.2022.2044512","DOIUrl":null,"url":null,"abstract":"Abstract Background SARS-CoV-2 pandemic represented a huge challenge for national health systems worldwide. Pooling nasopharyngeal (NP) swabs seems to be a promising strategy, saving time and resources, but it could reduce the sensitivity of the RT-PCR and exacerbate samples management in terms of automation and tracing. In this study, taking advantage of the routine implementation of a screening plan on health workers, we evaluated the feasibility of pool testing for SARS-CoV-2 infection diagnosis in the presence of low viral load samples. Method Pools were prepared with an automated instrument, mixing 4, 6 or 20 NP specimens, including one, two or none positive samples. Ct values of positive samples were on average about 35 for the four genes analyzed. Results The overall sensitivity of 4-samples and 6-samples pools was 93.1 and 90.0%, respectively. Focussing on pools including one sample with Ct value ≥35 for all analyzed genes, sensitivity decreased to 77.8 and 75.0% for 4- and 6-samples, respectively; pools including two positive samples, resulted positive in any size as well as pools including positive samples with Ct values <35. Conclusion Pool testing strategy should account the balance between cost-effectiveness, dilution effect and prevalence of the infection. Our study demonstrated the good performances in terms of sensitivity and saving resources of pool testing mixing 4 or 6 samples, even including low viral load specimens, in a real screening context possibly affected by prevalence fluctuation. In conclusion, pool testing strategy represents an efficient and resources saving surveillance and tracing tool, especially in specific context like schools, even for monitoring changes in prevalence associated to vaccination campaign.","PeriodicalId":13671,"journal":{"name":"Infectious Diseases","volume":"54 1","pages":"478 - 487"},"PeriodicalIF":4.0000,"publicationDate":"2022-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/23744235.2022.2044512","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 1
Abstract
Abstract Background SARS-CoV-2 pandemic represented a huge challenge for national health systems worldwide. Pooling nasopharyngeal (NP) swabs seems to be a promising strategy, saving time and resources, but it could reduce the sensitivity of the RT-PCR and exacerbate samples management in terms of automation and tracing. In this study, taking advantage of the routine implementation of a screening plan on health workers, we evaluated the feasibility of pool testing for SARS-CoV-2 infection diagnosis in the presence of low viral load samples. Method Pools were prepared with an automated instrument, mixing 4, 6 or 20 NP specimens, including one, two or none positive samples. Ct values of positive samples were on average about 35 for the four genes analyzed. Results The overall sensitivity of 4-samples and 6-samples pools was 93.1 and 90.0%, respectively. Focussing on pools including one sample with Ct value ≥35 for all analyzed genes, sensitivity decreased to 77.8 and 75.0% for 4- and 6-samples, respectively; pools including two positive samples, resulted positive in any size as well as pools including positive samples with Ct values <35. Conclusion Pool testing strategy should account the balance between cost-effectiveness, dilution effect and prevalence of the infection. Our study demonstrated the good performances in terms of sensitivity and saving resources of pool testing mixing 4 or 6 samples, even including low viral load specimens, in a real screening context possibly affected by prevalence fluctuation. In conclusion, pool testing strategy represents an efficient and resources saving surveillance and tracing tool, especially in specific context like schools, even for monitoring changes in prevalence associated to vaccination campaign.
期刊介绍:
Infectious Diseases (formerly Scandinavian Journal of Infectious Diseases) is a peer-reviewed journal publishing articles on all aspects of human infection, including pathogenesis, diagnosis, and treatment of infectious diseases, and also on medical microbiology and epidemiology