Effect of Mesh Homogeneity and Choice of Target Surface on Statistical Evaluation of Mesh Differences

Q2 Materials Science
Stefan Rues , Moritz Waldecker , Peter Rammelsberg, Andreas Zenthöfer
{"title":"Effect of Mesh Homogeneity and Choice of Target Surface on Statistical Evaluation of Mesh Differences","authors":"Stefan Rues ,&nbsp;Moritz Waldecker ,&nbsp;Peter Rammelsberg,&nbsp;Andreas Zenthöfer","doi":"10.1016/j.biotri.2021.100176","DOIUrl":null,"url":null,"abstract":"<div><p>In dentistry, clinical wear is typically measured by superimposition of plaster<span> replica scans of the patient's actual and baseline situation. Intraoral scanning could save time and circumvent replica fabrication and associated errors. However, intraoral scanners are made for commercial use without the possibility to implement comprehensive user-specific settings. Analysis of exported stl-data is, in general, executed with commercial quality control software.</span></p><p>This study investigated the effect of mesh inhomogeneities on distance measurements based on target surfaces generated by different scanners and parameter settings. To quantify errors, an analytical solution for mean value and standard deviation of evenly distributed distance measurements for a spherical cap situation (resembling either a worn cusp or a wear track in a once flat surface) was derived. In vitro experiments with scans of precise spherical moulds gradually reduced in height complemented the investigation.</p><p>Due to non-weighted statistics in the quality control software, errors increased with increasing mesh inhomogeneity. Worst results were given for intraoral scans with mean relative errors of up to 13.2% and 20.5% for mean value and standard deviation of the distributed distance measurements. Homogeneous remeshing of the intraoral scan surfaces could almost eliminate these unwished effects.</p></div>","PeriodicalId":38233,"journal":{"name":"Biotribology","volume":"26 ","pages":"Article 100176"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.biotri.2021.100176","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotribology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352573821000172","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 0

Abstract

In dentistry, clinical wear is typically measured by superimposition of plaster replica scans of the patient's actual and baseline situation. Intraoral scanning could save time and circumvent replica fabrication and associated errors. However, intraoral scanners are made for commercial use without the possibility to implement comprehensive user-specific settings. Analysis of exported stl-data is, in general, executed with commercial quality control software.

This study investigated the effect of mesh inhomogeneities on distance measurements based on target surfaces generated by different scanners and parameter settings. To quantify errors, an analytical solution for mean value and standard deviation of evenly distributed distance measurements for a spherical cap situation (resembling either a worn cusp or a wear track in a once flat surface) was derived. In vitro experiments with scans of precise spherical moulds gradually reduced in height complemented the investigation.

Due to non-weighted statistics in the quality control software, errors increased with increasing mesh inhomogeneity. Worst results were given for intraoral scans with mean relative errors of up to 13.2% and 20.5% for mean value and standard deviation of the distributed distance measurements. Homogeneous remeshing of the intraoral scan surfaces could almost eliminate these unwished effects.

网格均匀性和目标曲面选择对网格差异统计评价的影响
在牙科中,临床磨损通常是通过叠加患者实际情况和基线情况的石膏复制品扫描来测量的。口腔内扫描可以节省时间,避免复制和相关的错误。然而,口腔内扫描仪是为商业用途而制造的,没有可能实现全面的用户特定设置。一般来说,对导出的静态数据的分析是用商业质量控制软件执行的。本研究探讨了网格不均匀性对基于不同扫描仪和参数设置生成的目标表面的距离测量的影响。为了量化误差,推导了球形帽情况(类似于磨损的尖头或曾经平坦表面上的磨损轨迹)均匀分布距离测量的平均值和标准差的解析解。在体外实验中,精确的球形模具的扫描逐渐降低了高度,补充了研究。由于质量控制软件中的非加权统计,误差随着网格不均匀性的增加而增加。口腔内扫描结果最差,分布距离测量的平均值和标准差的平均相对误差高达13.2%和20.5%。口腔内扫描表面的均匀重网格几乎可以消除这些不希望的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biotribology
Biotribology Materials Science-Surfaces, Coatings and Films
CiteScore
4.20
自引率
0.00%
发文量
17
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信