A Field Study for SARS-CoV-2 Evaluation by Two Air Sampling Strategy During Spread in Tehran, Iran

IF 0.4 Q4 CHEMISTRY, ANALYTICAL
F. Bokharaei-Salim, R. Zendehdel, M. Helmi-Kohnehshahro, Z. Taherianfar
{"title":"A Field Study for SARS-CoV-2 Evaluation by Two Air Sampling Strategy During Spread in Tehran, Iran","authors":"F. Bokharaei-Salim, R. Zendehdel, M. Helmi-Kohnehshahro, Z. Taherianfar","doi":"10.21743/pjaec.2021.06.03","DOIUrl":null,"url":null,"abstract":"Outbreak of COVID-19 in different countries is an emergency in global public health recently. According to high spread of the newborn virus, airborne transmission potency of SARS-CoV-2 is possible. Until now, there are contradictory results for air evaluation of newborn virus in the contaminated area. We studied SARS-CoV-2 in the patient room of a hospital by two air sampling strategies. Filtration method and liquid impaction sampling were used simultaneously to assess SARS-CoV-2 in air. Indoor air of seven stations in three hospital wards was evaluated according to glass midget impinger and polytetrafluoroethylene filter. RNA of SARS-CoV-2 was evaluated by real time reverse transcription-PCR. Studied rooms were contaminated by eleven confirmed patients and four suspected cases. Our results show polytetrafluoroethylene filtration and DMEM impaction could not determine the viral concentration in the air samples. The concentration of SARS-CoV-2 in air samples is a trace in the studied stations. In conclusion, sampling strategy is a challenge for newborn virus due to the level of SARS-CoV-2 virus in the air. A trace level of SARS-CoV-2 in the contaminated area could be highlighted higher pathogenicity properties, not disapproval of airborne properties. However, more studies should be performed to characterize new properties of SARS-CoV-2 in the contaminated air.","PeriodicalId":19846,"journal":{"name":"Pakistan Journal of Analytical & Environmental Chemistry","volume":" ","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2021-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Journal of Analytical & Environmental Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21743/pjaec.2021.06.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Outbreak of COVID-19 in different countries is an emergency in global public health recently. According to high spread of the newborn virus, airborne transmission potency of SARS-CoV-2 is possible. Until now, there are contradictory results for air evaluation of newborn virus in the contaminated area. We studied SARS-CoV-2 in the patient room of a hospital by two air sampling strategies. Filtration method and liquid impaction sampling were used simultaneously to assess SARS-CoV-2 in air. Indoor air of seven stations in three hospital wards was evaluated according to glass midget impinger and polytetrafluoroethylene filter. RNA of SARS-CoV-2 was evaluated by real time reverse transcription-PCR. Studied rooms were contaminated by eleven confirmed patients and four suspected cases. Our results show polytetrafluoroethylene filtration and DMEM impaction could not determine the viral concentration in the air samples. The concentration of SARS-CoV-2 in air samples is a trace in the studied stations. In conclusion, sampling strategy is a challenge for newborn virus due to the level of SARS-CoV-2 virus in the air. A trace level of SARS-CoV-2 in the contaminated area could be highlighted higher pathogenicity properties, not disapproval of airborne properties. However, more studies should be performed to characterize new properties of SARS-CoV-2 in the contaminated air.
伊朗德黑兰传播期间通过两种空气采样策略评估严重急性呼吸系统综合征冠状病毒2型的现场研究
新冠肺炎在不同国家的爆发是最近全球公共卫生领域的一个紧急事件。根据新生儿病毒的高度传播,严重急性呼吸系统综合征冠状病毒2型的空气传播能力是可能的。到目前为止,污染地区新生儿病毒的空气评估结果相互矛盾。我们通过两种空气采样策略在一家医院的病房中研究了严重急性呼吸系统综合征冠状病毒2型。同时使用过滤法和液体冲击采样来评估空气中的严重急性呼吸系统综合征冠状病毒2型。采用玻璃微型冲击器和聚四氟乙烯过滤器对三个医院病房七个站的室内空气进行了评价。通过实时逆转录聚合酶链式反应评估严重急性呼吸系统综合征冠状病毒2型的RNA。研究室被11名确诊患者和4名疑似病例污染。我们的结果表明,聚四氟乙烯过滤和DMEM冲击不能确定空气样本中的病毒浓度。空气样本中严重急性呼吸系统综合征冠状病毒2型的浓度是研究站的一个痕迹。总之,由于空气中严重急性呼吸系统综合征冠状病毒2型的水平,采样策略对新生儿病毒来说是一个挑战。污染地区的严重急性呼吸系统综合征冠状病毒2型的微量水平可能突出了更高的致病性,而不是对空气传播特性的否定。然而,应该进行更多的研究来表征受污染空气中严重急性呼吸系统综合征冠状病毒2型的新特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
16.70%
发文量
16
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信