Results from the national intercomparison for rise time and bandwidth measurements within the German Calibration Service (Deutscher Kalibrierdienst – DKD)
{"title":"Results from the national intercomparison for rise time and bandwidth measurements within the German Calibration Service (Deutscher Kalibrierdienst – DKD)","authors":"K. Baaske, T. Kleine-Ostmann, T. Schrader","doi":"10.5194/ars-17-45-2019","DOIUrl":null,"url":null,"abstract":"Abstract. An intercomparison in the framework of the German Calibration Service (Deutscher\nKalibrierdienst – DKD) was carried out. Two different travelling standards\nwere used to measure the 10 % to 90 % rise time of a pulse generator and\nthe 10 % to 90 % rise time, −3 dB bandwidth and attenuation at 500 MHz\nof an oscilloscope. Fourteen participants performed the measurements from\nSeptember 2015 until May 2016.\n","PeriodicalId":45093,"journal":{"name":"Advances in Radio Science","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2019-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Radio Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/ars-17-45-2019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract. An intercomparison in the framework of the German Calibration Service (Deutscher
Kalibrierdienst – DKD) was carried out. Two different travelling standards
were used to measure the 10 % to 90 % rise time of a pulse generator and
the 10 % to 90 % rise time, −3 dB bandwidth and attenuation at 500 MHz
of an oscilloscope. Fourteen participants performed the measurements from
September 2015 until May 2016.