Separation, speciation and quantification of both chromium (VI) and chromium (III) in tanned leather samples: a comparative study and validation of analytical methods

Mónica Gisel Arellano-Sánchez, Juliette Vievard, Lamia Moufarrej, Christine Devouge-Boyer, Marie Hubert-Roux, Carlos Afonso, Mélanie Mignot
{"title":"Separation, speciation and quantification of both chromium (VI) and chromium (III) in tanned leather samples: a comparative study and validation of analytical methods","authors":"Mónica Gisel Arellano-Sánchez,&nbsp;Juliette Vievard,&nbsp;Lamia Moufarrej,&nbsp;Christine Devouge-Boyer,&nbsp;Marie Hubert-Roux,&nbsp;Carlos Afonso,&nbsp;Mélanie Mignot","doi":"10.1186/s42825-023-00125-7","DOIUrl":null,"url":null,"abstract":"<div><p>In the present work, a comparative study of analytical methods for the simultaneous and quantitative determination of trivalent and hexavalent chromium is presented. For the analysis by ion chromatography-inductively coupled plasma-mass spectrometry, two different columns were tested, as well as different mobile phases and different pH of the samples. The optimized analytical method permitted the separation of Cr(III) and Cr(VI) using 75 mmol/L NH<sub>4</sub>NO<sub>3</sub> pH 3 as chromatographic eluent. The method was validated and applied to real samples, allowing the determination of both species simultaneously, even when there is a huge difference of concentration between Cr(III) and Cr(VI). Limit of detection and limit of quantification for Cr(III) were found to be 0.016 and 0.054 <span>\\(\\upmu\\)</span>g/L (0.3 and 1.1 <span>\\(\\upmu\\)</span>g/kg), respectively, and for Cr(VI) 0.13 and 0.43 <span>\\(\\upmu\\)</span>g/L (7 and 22 <span>\\(\\upmu\\)</span>g/kg), respectively. Possible species interconversions were monitored through the use of chromium isotopic standards, which confirmed that the optimized methodology preserves chromium speciation during extraction and analysis. Fourier-transform ion cyclotron resonance-mass spectrometry permitted the structure elucidation of the complex formed during ethylenediaminetetraacetic acid extraction.</p><h3>Graphical Abstract</h3>\n <figure><div><div><div><picture><source><img></source></picture></div></div></div></figure>\n </div>","PeriodicalId":640,"journal":{"name":"Journal of Leather Science and Engineering","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://JLSE.SpringerOpen.com/counter/pdf/10.1186/s42825-023-00125-7","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Leather Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s42825-023-00125-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the present work, a comparative study of analytical methods for the simultaneous and quantitative determination of trivalent and hexavalent chromium is presented. For the analysis by ion chromatography-inductively coupled plasma-mass spectrometry, two different columns were tested, as well as different mobile phases and different pH of the samples. The optimized analytical method permitted the separation of Cr(III) and Cr(VI) using 75 mmol/L NH4NO3 pH 3 as chromatographic eluent. The method was validated and applied to real samples, allowing the determination of both species simultaneously, even when there is a huge difference of concentration between Cr(III) and Cr(VI). Limit of detection and limit of quantification for Cr(III) were found to be 0.016 and 0.054 \(\upmu\)g/L (0.3 and 1.1 \(\upmu\)g/kg), respectively, and for Cr(VI) 0.13 and 0.43 \(\upmu\)g/L (7 and 22 \(\upmu\)g/kg), respectively. Possible species interconversions were monitored through the use of chromium isotopic standards, which confirmed that the optimized methodology preserves chromium speciation during extraction and analysis. Fourier-transform ion cyclotron resonance-mass spectrometry permitted the structure elucidation of the complex formed during ethylenediaminetetraacetic acid extraction.

Graphical Abstract

鞣革样品中铬(VI)和铬(III)的分离、形态和定量:分析方法的比较研究和验证
对同时定量测定三价铬和六价铬的分析方法进行了比较研究。离子色谱-电感耦合等离子体质谱分析采用了两种不同的色谱柱、不同的流动相和不同的pH值。优化后的分析方法以75 mmol/L NH4NO3 pH 3为色谱洗脱液,可分离Cr(III)和Cr(VI)。该方法经过验证并应用于实际样品,即使Cr(III)和Cr(VI)的浓度差异很大,也可以同时测定两种物质。Cr(III)的检出限和定量限分别为0.016和0.054 \(\upmu\) g/L(0.3和1.1 \(\upmu\) g/kg), Cr(VI)的检出限和定量限分别为0.13和0.43 \(\upmu\) g/L(7和22 \(\upmu\) g/kg)。通过使用铬同位素标准来监测可能的物种相互转换,这证实了优化的方法在提取和分析过程中保留了铬的形态。傅里叶变换离子回旋共振质谱法对乙二胺四乙酸萃取过程中形成的络合物进行了结构解析。图形摘要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Leather Science and Engineering
Journal of Leather Science and Engineering 工程技术-材料科学:综合
CiteScore
12.80
自引率
0.00%
发文量
29
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信