A Turn-on Fluorescent Sensor For Cadmium Ion Detection In Aqueous Solutions

Q3 Chemistry
Ziya Aydin
{"title":"A Turn-on Fluorescent Sensor For Cadmium Ion Detection In Aqueous Solutions","authors":"Ziya Aydin","doi":"10.18596/jotcsa.638912","DOIUrl":null,"url":null,"abstract":"Fluorescent sensors have attracted an important interest due to their advantages such as high selectivity, rapid response, easy to use etc. In this study, a rhodamine based fluorescent sensor, RhDP, was synthesized, and used for selective detection of Cd 2+ ions. The sensor responds to Cd 2+ via the coordination induced fluorescence activation (CIFA) mechanism. RhDP gives a very fast and reversible fluorescence response to Cd 2+ in the presence of the metal ions tested. The complex stoichiometry between RhDP and Cd 2+ was found to be 1:1 and the binding constant was calculated as 2.70 × 10 7 M -1 in ACN/HEPES buffer (10 mM, pH: 7.05, v/v 1:1). The fluorescent detection limit of RhDP for Cd 2+ was found to be 0.218  µ M, which gave a marked sensitivity towards Cd 2+ .","PeriodicalId":17402,"journal":{"name":"Journal of the Turkish Chemical Society, Section A: Chemistry","volume":"7 1","pages":"277-286"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Turkish Chemical Society, Section A: Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18596/jotcsa.638912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 2

Abstract

Fluorescent sensors have attracted an important interest due to their advantages such as high selectivity, rapid response, easy to use etc. In this study, a rhodamine based fluorescent sensor, RhDP, was synthesized, and used for selective detection of Cd 2+ ions. The sensor responds to Cd 2+ via the coordination induced fluorescence activation (CIFA) mechanism. RhDP gives a very fast and reversible fluorescence response to Cd 2+ in the presence of the metal ions tested. The complex stoichiometry between RhDP and Cd 2+ was found to be 1:1 and the binding constant was calculated as 2.70 × 10 7 M -1 in ACN/HEPES buffer (10 mM, pH: 7.05, v/v 1:1). The fluorescent detection limit of RhDP for Cd 2+ was found to be 0.218  µ M, which gave a marked sensitivity towards Cd 2+ .
一种用于检测水溶液中镉离子的荧光传感器
荧光传感器以其高选择性、快速响应、易于使用等优点引起了人们的极大兴趣。本研究合成了一种基于罗丹明的荧光传感器RhDP,并将其用于Cd2+离子的选择性检测。该传感器通过配位诱导荧光激活(CIFA)机制对Cd2+产生反应。RhDP在金属离子存在下对Cd2+有很快且可逆的荧光响应。在ACN/HEPES缓冲液(10mM,pH:7.05,v/v1:1)中,RhDP与Cd2+的络合化学计量为1:1,结合常数为2.70×107M-1。RhDP对Cd2+的荧光检测限为0.218µM,对Cd2+具有显著的敏感性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.60
自引率
0.00%
发文量
81
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信