Min So Jo, Jaclyn Moon, S. Chung, E. Kim, Kyu Hong Park, J. Choi
{"title":"Efficacy of Biometry Using Swept-source Optical Coherence Tomography for Posterior Chamber Phakic Intraocular Lens Implantation","authors":"Min So Jo, Jaclyn Moon, S. Chung, E. Kim, Kyu Hong Park, J. Choi","doi":"10.3341/jkos.2023.64.5.374","DOIUrl":null,"url":null,"abstract":"Purpose: The proper implantable collamer lens (ICL) size affects ICL stability. This study compared device efficacy using white-to-white diameter (WTW) measurements with Orbscan II and IOL Master 700.Methods: We retrospectively studied 90 eyes (45 patients) who underwent toric ICL implantation from January 2019 to February 2020 and were followed for 1 year. The correlation between WTW and anterior chamber depth (ACD) for each measuring device was analyzed.Results: The mean WTW measured by IOL Master 700 and Orbscan II was 12.2 ± 0.3 and 11.6 ± 0.3 mm, respectively, while the mean ACD was 3.28 ± 0.16 and 3.20 ± 0.15 mm. The WTW and ACD measured with IOL Master 700 averaged 0.57 ± 0.12 and 0.08 ± 0.04 mm larger than with Orbscan II. The differences were significant and the regression analysis had high correlations (R2 = 0.875 and R2 = 0.913, respectively; both p < 0.001).Conclusions: WTW measured by the IOL Master 700 can be used as a reference either alone or together with the Orbscan II value to determine ICL size.","PeriodicalId":17341,"journal":{"name":"Journal of The Korean Ophthalmological Society","volume":" ","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2023.64.5.374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The proper implantable collamer lens (ICL) size affects ICL stability. This study compared device efficacy using white-to-white diameter (WTW) measurements with Orbscan II and IOL Master 700.Methods: We retrospectively studied 90 eyes (45 patients) who underwent toric ICL implantation from January 2019 to February 2020 and were followed for 1 year. The correlation between WTW and anterior chamber depth (ACD) for each measuring device was analyzed.Results: The mean WTW measured by IOL Master 700 and Orbscan II was 12.2 ± 0.3 and 11.6 ± 0.3 mm, respectively, while the mean ACD was 3.28 ± 0.16 and 3.20 ± 0.15 mm. The WTW and ACD measured with IOL Master 700 averaged 0.57 ± 0.12 and 0.08 ± 0.04 mm larger than with Orbscan II. The differences were significant and the regression analysis had high correlations (R2 = 0.875 and R2 = 0.913, respectively; both p < 0.001).Conclusions: WTW measured by the IOL Master 700 can be used as a reference either alone or together with the Orbscan II value to determine ICL size.