{"title":"Dual-Parameter Sensing With a Single Supermode Interferometer","authors":"J. A. Flores-Bravo, J. Villatoro","doi":"10.3389/fsens.2022.820612","DOIUrl":null,"url":null,"abstract":"Optical fiber interferometers have intrinsic sensitivity to temperature, thus, in sensing applications; they need a reference temperature sensor or a mechanism to control the temperature. Here, we demonstrate that a single multicore fiber interferometer can monitor two parameters simultaneously; more particularly, refractive index, and temperature. The interferometer is easy to manufacture; a short segment of an optical fiber with seven coupled cores is fusion spliced at the distal end of a conventional single mode optical fiber. In the coupled-core fiber, two supermodes beat; this makes the reflection spectrum of the device to exhibit a well-defined series of maxima and minima. The refractive index of a sample in contact with multicore fiber alters the amplitude of the interference pattern and temperature induces a shift to such a pattern. The changes of the interference pattern are easy to monitor and decode with a low-resolution spectrometer. As an application of our dual-parameter sensor, the thermo-optic coefficient of a sample was measured.","PeriodicalId":93754,"journal":{"name":"Frontiers in sensors","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in sensors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/fsens.2022.820612","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Optical fiber interferometers have intrinsic sensitivity to temperature, thus, in sensing applications; they need a reference temperature sensor or a mechanism to control the temperature. Here, we demonstrate that a single multicore fiber interferometer can monitor two parameters simultaneously; more particularly, refractive index, and temperature. The interferometer is easy to manufacture; a short segment of an optical fiber with seven coupled cores is fusion spliced at the distal end of a conventional single mode optical fiber. In the coupled-core fiber, two supermodes beat; this makes the reflection spectrum of the device to exhibit a well-defined series of maxima and minima. The refractive index of a sample in contact with multicore fiber alters the amplitude of the interference pattern and temperature induces a shift to such a pattern. The changes of the interference pattern are easy to monitor and decode with a low-resolution spectrometer. As an application of our dual-parameter sensor, the thermo-optic coefficient of a sample was measured.