{"title":"A Discrimination Method Between Transformer Inrush and Fault Current Based on Chromatic Monitoring","authors":"Z. Almajali","doi":"10.37394/232016.2021.16.31","DOIUrl":null,"url":null,"abstract":"For successful transformer differential protection employment, correct discrimination between inrush current and fault current is essential. It is one of the main focuses of research and one of the main challenges for transformer protection. In this paper, a discrimination method based on utilizing chromatic monitoring of the box dimension algorithm outcome curve for transformer differential current in time-domain analysis is proposed. The x-L chromatic mapping is employed for general detection of fault cases, while the x-y chromatic mapping result is used for distinguishing inrush current from the fault current cycles. The preliminary results show that the proposed method can effectively provide correct discrimination of the current type within quite a short time and thus help in providing efficient decision-making supportive protection tool.","PeriodicalId":38993,"journal":{"name":"WSEAS Transactions on Power Systems","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"WSEAS Transactions on Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37394/232016.2021.16.31","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
For successful transformer differential protection employment, correct discrimination between inrush current and fault current is essential. It is one of the main focuses of research and one of the main challenges for transformer protection. In this paper, a discrimination method based on utilizing chromatic monitoring of the box dimension algorithm outcome curve for transformer differential current in time-domain analysis is proposed. The x-L chromatic mapping is employed for general detection of fault cases, while the x-y chromatic mapping result is used for distinguishing inrush current from the fault current cycles. The preliminary results show that the proposed method can effectively provide correct discrimination of the current type within quite a short time and thus help in providing efficient decision-making supportive protection tool.
期刊介绍:
WSEAS Transactions on Power Systems publishes original research papers relating to electric power and energy. We aim to bring important work to a wide international audience and therefore only publish papers of exceptional scientific value that advance our understanding of these particular areas. The research presented must transcend the limits of case studies, while both experimental and theoretical studies are accepted. It is a multi-disciplinary journal and therefore its content mirrors the diverse interests and approaches of scholars involved with generation, transmission & distribution planning, alternative energy systems, power market, switching and related areas. We also welcome scholarly contributions from officials with government agencies, international agencies, and non-governmental organizations.